gx5_link reference frame location #17

Open
Enmar123 opened this issue May 23, 2019 · 3 comments
Open

gx5_link reference frame location #17

Enmar123 opened this issue May 23, 2019 · 3 comments

Comments

@Enmar123
Copy link

I would like to know where on an IMU the "gx5_link" reference frame is located to build an accurate transform to it. Not all Lord IMU's are shaped the same, is there a general rule for locating this reference frame on your model or is the location unique to every model?

My IMU: 3DM-CX5-25

@tonybaltovski
Copy link
Member

As far as I know, all IMUs have their axes labelled so use that as reference.

@bsb808
Copy link
Collaborator

bsb808 commented May 24, 2019

I believe the discussion on issue #4 may be what you are looking for - true?

We really should create some documentation on these issues to avoid confusion. I will try to make some time, but would be very thankful if others could help with how they are putting the devices to use.

@Enmar123
Copy link
Author

I saw the reference frame discussion on issue #4 and it was quite helpful for determining the correct IMU orientation. I have also decided to use the axes marker for the translation component of my transform, is this a good idea?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment