From 9032548ea2ce4da2a9f04d26c8dcbd66d9eed71c Mon Sep 17 00:00:00 2001 From: James Swan <122404367+swan-amazon@users.noreply.github.com> Date: Tue, 30 Jul 2024 13:24:49 -0700 Subject: [PATCH] Add TC feature definitions to General Commissioning Cluster XML files (#34604) * Add TC feature definitions to General Commissioning Cluster XML files This commit introduces the "Terms and Conditions" (TC) feature definitions to the General Commissioning Cluster XML data model files. The changes include new attributes, commands, and commissioning errors related to the TC feature. Changes include: - Added TC feature definition with bitmask. - Introduced new commissioning errors related to TC: - RequiredTCNotAccepted - TCAcknowledgementsNotReceived - TCMinVersionNotMet - Added new attributes for TC: - TCAcceptedVersion - TCMinRequiredVersion - TCAcknowledgements - TCAcknowledgementsRequired - Added new commands for TC acknowledgements: - SetTCAcknowledgements - SetTCAcknowledgementsResponse These changes only modify the XML files. A follow-up commit will regenerate the necessary files. * Zap regen for Enhanced Setup Flow, Terms and Conditions (TC) * Auto-update ZAP files. ```bash python3 ./scripts/tools/zap_regen_all.py ``` --- .../air-purifier-app.matter | 22 + .../air-quality-sensor-app.matter | 22 + .../all-clusters-app.matter | 22 + .../all-clusters-minimal-app.matter | 22 + .../bridge-common/bridge-app.matter | 22 + ...p_rootnode_dimmablelight_bCwGYSDpoe.matter | 22 + .../rootnode_airpurifier_73a6fe2651.matter | 22 + ...umiditysensor_thermostat_56de3d5f45.matter | 22 + ...ootnode_airqualitysensor_e63187f6c9.matter | 22 + ...ootnode_basicvideoplayer_0ff86e943b.matter | 22 + ...de_colortemperaturelight_hbUnzYVeyn.matter | 22 + .../rootnode_contactsensor_27f76aeaf5.matter | 22 + .../rootnode_contactsensor_lFAGG1bfRO.matter | 22 + .../rootnode_dimmablelight_bCwGYSDpoe.matter | 22 + ...tnode_dimmablepluginunit_f8a9a0b9d4.matter | 22 + .../rootnode_dishwasher_cc105034fe.matter | 22 + .../rootnode_doorlock_aNKYAreMXE.matter | 22 + ...tnode_extendedcolorlight_8lcaaYJVAa.matter | 22 + .../devices/rootnode_fan_7N2TobIlOX.matter | 22 + .../rootnode_flowsensor_1zVxHedlaV.matter | 22 + .../rootnode_genericswitch_2dfff6e516.matter | 22 + .../rootnode_genericswitch_9866e35d0b.matter | 22 + ...tnode_heatingcoolingunit_ncdGai1E5a.matter | 22 + .../rootnode_humiditysensor_Xyj4gda6Hb.matter | 22 + .../rootnode_laundrywasher_fb10d238c8.matter | 22 + .../rootnode_lightsensor_lZQycTFcJK.matter | 22 + ...rootnode_occupancysensor_iHyVgifZuo.matter | 22 + .../rootnode_onofflight_bbs1b7IaOV.matter | 22 + .../rootnode_onofflight_samplemei.matter | 22 + ...ootnode_onofflightswitch_FsPlMr090Q.matter | 22 + ...rootnode_onoffpluginunit_Wtf8ss5EBY.matter | 22 + .../rootnode_pressuresensor_s0qC9wLH4k.matter | 22 + .../devices/rootnode_pump_5f904818cc.matter | 22 + .../devices/rootnode_pump_a811bb33a0.matter | 22 + ...eraturecontrolledcabinet_ffdb696680.matter | 22 + ...ode_roboticvacuumcleaner_1807ff0c49.matter | 22 + ...tnode_roomairconditioner_9cf3607804.matter | 22 + .../rootnode_smokecoalarm_686fe0dcb8.matter | 22 + .../rootnode_speaker_RpzeXdimqA.matter | 22 + ...otnode_temperaturesensor_Qy1zkNW7c3.matter | 22 + .../rootnode_thermostat_bm3fb8dhYi.matter | 22 + .../rootnode_windowcovering_RLCxaGi9Yx.matter | 22 + .../contact-sensor-app.matter | 22 + .../nxp/zap-lit/contact-sensor-app.matter | 22 + .../nxp/zap-sit/contact-sensor-app.matter | 22 + .../dishwasher-common/dishwasher-app.matter | 22 + .../energy-management-app.matter | 22 + .../fabric-bridge-app.matter | 22 + .../nxp/zap/laundry-washer-app.matter | 22 + .../light-switch-app.matter | 22 + .../light-switch-app/qpg/zap/switch.matter | 22 + .../data_model/lighting-app-ethernet.matter | 22 + .../data_model/lighting-app-thread.matter | 22 + .../data_model/lighting-app-wifi.matter | 22 + .../lighting-common/lighting-app.matter | 22 + .../nxp/zap/lighting-on-off.matter | 22 + examples/lighting-app/qpg/zap/light.matter | 22 + .../data_model/lighting-thread-app.matter | 22 + .../data_model/lighting-wifi-app.matter | 22 + .../lit-icd-common/lit-icd-server-app.matter | 22 + examples/lock-app/lock-common/lock-app.matter | 22 + examples/lock-app/nxp/zap/lock-app.matter | 22 + examples/lock-app/qpg/zap/lock.matter | 22 + .../log-source-common/log-source-app.matter | 22 + .../microwave-oven-app.matter | 22 + .../network-manager-app.matter | 22 + .../ota-provider-app.matter | 22 + .../ota-requestor-app.matter | 22 + .../placeholder/linux/apps/app1/config.matter | 44 ++ .../placeholder/linux/apps/app2/config.matter | 44 ++ examples/pump-app/pump-common/pump-app.matter | 22 + .../silabs/data_model/pump-thread-app.matter | 22 + .../silabs/data_model/pump-wifi-app.matter | 22 + .../pump-controller-app.matter | 22 + .../refrigerator-app.matter | 22 + examples/rvc-app/rvc-common/rvc-app.matter | 22 + .../smoke-co-alarm-app.matter | 22 + .../temperature-measurement.matter | 22 + .../nxp/zap/thermostat_matter_thread.matter | 22 + .../nxp/zap/thermostat_matter_wifi.matter | 22 + .../qpg/zap/thermostaticRadiatorValve.matter | 22 + .../thermostat-common/thermostat.matter | 22 + examples/tv-app/tv-common/tv-app.matter | 44 ++ .../tv-casting-common/tv-casting-app.matter | 22 + .../virtual-device-app.matter | 22 + examples/window-app/common/window-app.matter | 22 + .../chip/general-commissioning-cluster.xml | 40 +- .../data_model/controller-clusters.matter | 22 + .../chip/devicecontroller/ChipClusters.java | 146 ++++++ .../devicecontroller/ClusterIDMapping.java | 24 +- .../devicecontroller/ClusterInfoMapping.java | 46 ++ .../devicecontroller/ClusterReadMapping.java | 44 ++ .../clusters/GeneralCommissioningCluster.kt | 425 +++++++++++++++++ .../CHIPAttributeTLVValueDecoder.cpp | 64 +++ .../python/chip/clusters/CHIPClusters.py | 32 ++ .../python/chip/clusters/Objects.py | 115 ++++- .../CHIP/templates/availability.yaml | 20 + .../MTRAttributeSpecifiedCheck.mm | 12 + .../MTRAttributeTLVValueDecoder.mm | 44 ++ .../CHIP/zap-generated/MTRBaseClusters.h | 37 ++ .../CHIP/zap-generated/MTRBaseClusters.mm | 168 +++++++ .../CHIP/zap-generated/MTRClusterConstants.h | 6 + .../CHIP/zap-generated/MTRClusterNames.mm | 16 + .../CHIP/zap-generated/MTRClusters.h | 9 + .../CHIP/zap-generated/MTRClusters.mm | 47 ++ .../zap-generated/MTRCommandPayloadsObjc.h | 51 +++ .../zap-generated/MTRCommandPayloadsObjc.mm | 164 +++++++ .../MTRCommandPayloads_Internal.h | 12 + .../zap-generated/attributes/Accessors.cpp | 185 ++++++++ .../zap-generated/attributes/Accessors.h | 24 + .../app-common/zap-generated/callback.h | 6 + .../zap-generated/cluster-enums-check.h | 3 + .../app-common/zap-generated/cluster-enums.h | 21 +- .../zap-generated/cluster-objects.cpp | 81 ++++ .../zap-generated/cluster-objects.h | 129 ++++++ .../app-common/zap-generated/ids/Attributes.h | 16 + .../app-common/zap-generated/ids/Commands.h | 8 + .../zap-generated/cluster/Commands.h | 63 +++ .../cluster/logging/DataModelLogger.cpp | 33 ++ .../cluster/logging/DataModelLogger.h | 3 + .../zap-generated/cluster/Commands.h | 431 ++++++++++++++++++ 121 files changed, 4495 insertions(+), 10 deletions(-) diff --git a/examples/air-purifier-app/air-purifier-common/air-purifier-app.matter b/examples/air-purifier-app/air-purifier-common/air-purifier-app.matter index 6e31f82460ed3a..ddfccaae2a712c 100644 --- a/examples/air-purifier-app/air-purifier-common/air-purifier-app.matter +++ b/examples/air-purifier-app/air-purifier-common/air-purifier-app.matter @@ -491,6 +491,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -499,6 +502,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -509,6 +516,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -542,12 +553,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/air-quality-sensor-app/air-quality-sensor-common/air-quality-sensor-app.matter b/examples/air-quality-sensor-app/air-quality-sensor-common/air-quality-sensor-app.matter index c7395570fccff4..9bffe726724599 100644 --- a/examples/air-quality-sensor-app/air-quality-sensor-common/air-quality-sensor-app.matter +++ b/examples/air-quality-sensor-app/air-quality-sensor-common/air-quality-sensor-app.matter @@ -491,6 +491,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -499,6 +502,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -509,6 +516,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -542,12 +553,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/all-clusters-app/all-clusters-common/all-clusters-app.matter b/examples/all-clusters-app/all-clusters-common/all-clusters-app.matter index 1d15ec2b1d85d6..e33b8841c5d716 100644 --- a/examples/all-clusters-app/all-clusters-common/all-clusters-app.matter +++ b/examples/all-clusters-app/all-clusters-common/all-clusters-app.matter @@ -1429,6 +1429,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1437,6 +1440,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1447,6 +1454,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1480,12 +1491,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/all-clusters-minimal-app/all-clusters-common/all-clusters-minimal-app.matter b/examples/all-clusters-minimal-app/all-clusters-common/all-clusters-minimal-app.matter index 8dfd81caf3a866..a5c35ac22619af 100644 --- a/examples/all-clusters-minimal-app/all-clusters-common/all-clusters-minimal-app.matter +++ b/examples/all-clusters-minimal-app/all-clusters-common/all-clusters-minimal-app.matter @@ -1309,6 +1309,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1317,6 +1320,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1327,6 +1334,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1360,12 +1371,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/bridge-app/bridge-common/bridge-app.matter b/examples/bridge-app/bridge-common/bridge-app.matter index f35fd082eb9900..464f3e2f9a513b 100644 --- a/examples/bridge-app/bridge-common/bridge-app.matter +++ b/examples/bridge-app/bridge-common/bridge-app.matter @@ -948,6 +948,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -956,6 +959,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -966,6 +973,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -999,12 +1010,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/noip_rootnode_dimmablelight_bCwGYSDpoe.matter b/examples/chef/devices/noip_rootnode_dimmablelight_bCwGYSDpoe.matter index ed03c1ca8ca637..c32b9263f77fd9 100644 --- a/examples/chef/devices/noip_rootnode_dimmablelight_bCwGYSDpoe.matter +++ b/examples/chef/devices/noip_rootnode_dimmablelight_bCwGYSDpoe.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** The cluster provides commands for retrieving unstructured diagnostic logs from a Node that may be used to aid in diagnostics. */ diff --git a/examples/chef/devices/rootnode_airpurifier_73a6fe2651.matter b/examples/chef/devices/rootnode_airpurifier_73a6fe2651.matter index ae8cdd66b8dd1b..96b3fa5df3f9b5 100644 --- a/examples/chef/devices/rootnode_airpurifier_73a6fe2651.matter +++ b/examples/chef/devices/rootnode_airpurifier_73a6fe2651.matter @@ -563,6 +563,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -571,6 +574,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -581,6 +588,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -614,12 +625,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_airpurifier_airqualitysensor_temperaturesensor_humiditysensor_thermostat_56de3d5f45.matter b/examples/chef/devices/rootnode_airpurifier_airqualitysensor_temperaturesensor_humiditysensor_thermostat_56de3d5f45.matter index e79a65f165d0d0..915da87f5ec794 100644 --- a/examples/chef/devices/rootnode_airpurifier_airqualitysensor_temperaturesensor_humiditysensor_thermostat_56de3d5f45.matter +++ b/examples/chef/devices/rootnode_airpurifier_airqualitysensor_temperaturesensor_humiditysensor_thermostat_56de3d5f45.matter @@ -414,6 +414,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -422,6 +425,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -432,6 +439,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -465,12 +476,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_airqualitysensor_e63187f6c9.matter b/examples/chef/devices/rootnode_airqualitysensor_e63187f6c9.matter index 7f86f3a66008b6..58038e843e97fc 100644 --- a/examples/chef/devices/rootnode_airqualitysensor_e63187f6c9.matter +++ b/examples/chef/devices/rootnode_airqualitysensor_e63187f6c9.matter @@ -811,6 +811,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -819,6 +822,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -829,6 +836,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -862,12 +873,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_basicvideoplayer_0ff86e943b.matter b/examples/chef/devices/rootnode_basicvideoplayer_0ff86e943b.matter index f65d5fc5ad8555..0ce0bdb04dbfa7 100644 --- a/examples/chef/devices/rootnode_basicvideoplayer_0ff86e943b.matter +++ b/examples/chef/devices/rootnode_basicvideoplayer_0ff86e943b.matter @@ -705,6 +705,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -713,6 +716,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -723,6 +730,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -756,12 +767,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_colortemperaturelight_hbUnzYVeyn.matter b/examples/chef/devices/rootnode_colortemperaturelight_hbUnzYVeyn.matter index 6f7714fcbbf102..1adf554340e63f 100644 --- a/examples/chef/devices/rootnode_colortemperaturelight_hbUnzYVeyn.matter +++ b/examples/chef/devices/rootnode_colortemperaturelight_hbUnzYVeyn.matter @@ -765,6 +765,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -773,6 +776,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -783,6 +790,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -816,12 +827,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_contactsensor_27f76aeaf5.matter b/examples/chef/devices/rootnode_contactsensor_27f76aeaf5.matter index 57718ed32895da..07b6b96881b48c 100644 --- a/examples/chef/devices/rootnode_contactsensor_27f76aeaf5.matter +++ b/examples/chef/devices/rootnode_contactsensor_27f76aeaf5.matter @@ -750,6 +750,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -758,6 +761,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -768,6 +775,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -801,12 +812,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_contactsensor_lFAGG1bfRO.matter b/examples/chef/devices/rootnode_contactsensor_lFAGG1bfRO.matter index 93df8c3e2c0b33..e132687fc65220 100644 --- a/examples/chef/devices/rootnode_contactsensor_lFAGG1bfRO.matter +++ b/examples/chef/devices/rootnode_contactsensor_lFAGG1bfRO.matter @@ -909,6 +909,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -917,6 +920,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -927,6 +934,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -960,12 +971,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_dimmablelight_bCwGYSDpoe.matter b/examples/chef/devices/rootnode_dimmablelight_bCwGYSDpoe.matter index 9dd5331063e27b..17996c2f9bfc42 100644 --- a/examples/chef/devices/rootnode_dimmablelight_bCwGYSDpoe.matter +++ b/examples/chef/devices/rootnode_dimmablelight_bCwGYSDpoe.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_dimmablepluginunit_f8a9a0b9d4.matter b/examples/chef/devices/rootnode_dimmablepluginunit_f8a9a0b9d4.matter index 90b81ab8df5b44..f860ab97b90e25 100644 --- a/examples/chef/devices/rootnode_dimmablepluginunit_f8a9a0b9d4.matter +++ b/examples/chef/devices/rootnode_dimmablepluginunit_f8a9a0b9d4.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_dishwasher_cc105034fe.matter b/examples/chef/devices/rootnode_dishwasher_cc105034fe.matter index 67684011eff2b4..7f236d311fbef9 100644 --- a/examples/chef/devices/rootnode_dishwasher_cc105034fe.matter +++ b/examples/chef/devices/rootnode_dishwasher_cc105034fe.matter @@ -424,6 +424,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -432,6 +435,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -442,6 +449,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -475,12 +486,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_doorlock_aNKYAreMXE.matter b/examples/chef/devices/rootnode_doorlock_aNKYAreMXE.matter index ae0d89f00a685f..38fa4895bc1e3d 100644 --- a/examples/chef/devices/rootnode_doorlock_aNKYAreMXE.matter +++ b/examples/chef/devices/rootnode_doorlock_aNKYAreMXE.matter @@ -811,6 +811,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -819,6 +822,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -829,6 +836,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -862,12 +873,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_extendedcolorlight_8lcaaYJVAa.matter b/examples/chef/devices/rootnode_extendedcolorlight_8lcaaYJVAa.matter index 32244ab3a10758..0ae2064972605a 100644 --- a/examples/chef/devices/rootnode_extendedcolorlight_8lcaaYJVAa.matter +++ b/examples/chef/devices/rootnode_extendedcolorlight_8lcaaYJVAa.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_fan_7N2TobIlOX.matter b/examples/chef/devices/rootnode_fan_7N2TobIlOX.matter index 3b0a153455d728..8d41f2e9b0197c 100644 --- a/examples/chef/devices/rootnode_fan_7N2TobIlOX.matter +++ b/examples/chef/devices/rootnode_fan_7N2TobIlOX.matter @@ -629,6 +629,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -637,6 +640,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -647,6 +654,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -680,12 +691,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_flowsensor_1zVxHedlaV.matter b/examples/chef/devices/rootnode_flowsensor_1zVxHedlaV.matter index 8cb484be472e10..5edf324c8213df 100644 --- a/examples/chef/devices/rootnode_flowsensor_1zVxHedlaV.matter +++ b/examples/chef/devices/rootnode_flowsensor_1zVxHedlaV.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_genericswitch_2dfff6e516.matter b/examples/chef/devices/rootnode_genericswitch_2dfff6e516.matter index 3a720c7c805fbf..95dcf542a8ab70 100644 --- a/examples/chef/devices/rootnode_genericswitch_2dfff6e516.matter +++ b/examples/chef/devices/rootnode_genericswitch_2dfff6e516.matter @@ -596,6 +596,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -604,6 +607,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -614,6 +621,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -647,12 +658,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_genericswitch_9866e35d0b.matter b/examples/chef/devices/rootnode_genericswitch_9866e35d0b.matter index 020c9f0a93c8ed..5e6025b776607f 100644 --- a/examples/chef/devices/rootnode_genericswitch_9866e35d0b.matter +++ b/examples/chef/devices/rootnode_genericswitch_9866e35d0b.matter @@ -596,6 +596,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -604,6 +607,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -614,6 +621,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -647,12 +658,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_heatingcoolingunit_ncdGai1E5a.matter b/examples/chef/devices/rootnode_heatingcoolingunit_ncdGai1E5a.matter index 40ddedabc2060d..06ccc592e9c4d4 100644 --- a/examples/chef/devices/rootnode_heatingcoolingunit_ncdGai1E5a.matter +++ b/examples/chef/devices/rootnode_heatingcoolingunit_ncdGai1E5a.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_humiditysensor_Xyj4gda6Hb.matter b/examples/chef/devices/rootnode_humiditysensor_Xyj4gda6Hb.matter index 6db777fbefbfe5..39e196626e518a 100644 --- a/examples/chef/devices/rootnode_humiditysensor_Xyj4gda6Hb.matter +++ b/examples/chef/devices/rootnode_humiditysensor_Xyj4gda6Hb.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_laundrywasher_fb10d238c8.matter b/examples/chef/devices/rootnode_laundrywasher_fb10d238c8.matter index 878c3ca1a435c5..460d6988c91959 100644 --- a/examples/chef/devices/rootnode_laundrywasher_fb10d238c8.matter +++ b/examples/chef/devices/rootnode_laundrywasher_fb10d238c8.matter @@ -424,6 +424,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -432,6 +435,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -442,6 +449,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -475,12 +486,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_lightsensor_lZQycTFcJK.matter b/examples/chef/devices/rootnode_lightsensor_lZQycTFcJK.matter index 8a6aa2ec17f178..705162a8be6fa8 100644 --- a/examples/chef/devices/rootnode_lightsensor_lZQycTFcJK.matter +++ b/examples/chef/devices/rootnode_lightsensor_lZQycTFcJK.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_occupancysensor_iHyVgifZuo.matter b/examples/chef/devices/rootnode_occupancysensor_iHyVgifZuo.matter index 434f47c71fd7f8..3a1a98807efe29 100644 --- a/examples/chef/devices/rootnode_occupancysensor_iHyVgifZuo.matter +++ b/examples/chef/devices/rootnode_occupancysensor_iHyVgifZuo.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_onofflight_bbs1b7IaOV.matter b/examples/chef/devices/rootnode_onofflight_bbs1b7IaOV.matter index d0b5b1a910c11d..9c4ff1c67bc2c0 100644 --- a/examples/chef/devices/rootnode_onofflight_bbs1b7IaOV.matter +++ b/examples/chef/devices/rootnode_onofflight_bbs1b7IaOV.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_onofflight_samplemei.matter b/examples/chef/devices/rootnode_onofflight_samplemei.matter index 17140385015901..19d0b2d0dd506e 100644 --- a/examples/chef/devices/rootnode_onofflight_samplemei.matter +++ b/examples/chef/devices/rootnode_onofflight_samplemei.matter @@ -847,6 +847,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -855,6 +858,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -865,6 +872,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -898,12 +909,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_onofflightswitch_FsPlMr090Q.matter b/examples/chef/devices/rootnode_onofflightswitch_FsPlMr090Q.matter index cb9f7f2eb6a4ae..ed135332fefbb4 100644 --- a/examples/chef/devices/rootnode_onofflightswitch_FsPlMr090Q.matter +++ b/examples/chef/devices/rootnode_onofflightswitch_FsPlMr090Q.matter @@ -794,6 +794,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -802,6 +805,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -812,6 +819,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -845,12 +856,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_onoffpluginunit_Wtf8ss5EBY.matter b/examples/chef/devices/rootnode_onoffpluginunit_Wtf8ss5EBY.matter index 627b2c18d523bd..fbc2e10cf430eb 100644 --- a/examples/chef/devices/rootnode_onoffpluginunit_Wtf8ss5EBY.matter +++ b/examples/chef/devices/rootnode_onoffpluginunit_Wtf8ss5EBY.matter @@ -722,6 +722,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -730,6 +733,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -740,6 +747,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -773,12 +784,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_pressuresensor_s0qC9wLH4k.matter b/examples/chef/devices/rootnode_pressuresensor_s0qC9wLH4k.matter index 67dbddaec37748..002e6fb6ce0f2a 100644 --- a/examples/chef/devices/rootnode_pressuresensor_s0qC9wLH4k.matter +++ b/examples/chef/devices/rootnode_pressuresensor_s0qC9wLH4k.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_pump_5f904818cc.matter b/examples/chef/devices/rootnode_pump_5f904818cc.matter index 9a2c1905f3ec86..afa0cd4d471863 100644 --- a/examples/chef/devices/rootnode_pump_5f904818cc.matter +++ b/examples/chef/devices/rootnode_pump_5f904818cc.matter @@ -496,6 +496,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -504,6 +507,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -514,6 +521,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -547,12 +558,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_pump_a811bb33a0.matter b/examples/chef/devices/rootnode_pump_a811bb33a0.matter index ee410b2a06de4c..6b61dae69dd48c 100644 --- a/examples/chef/devices/rootnode_pump_a811bb33a0.matter +++ b/examples/chef/devices/rootnode_pump_a811bb33a0.matter @@ -496,6 +496,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -504,6 +507,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -514,6 +521,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -547,12 +558,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_refrigerator_temperaturecontrolledcabinet_temperaturecontrolledcabinet_ffdb696680.matter b/examples/chef/devices/rootnode_refrigerator_temperaturecontrolledcabinet_temperaturecontrolledcabinet_ffdb696680.matter index 7da74be02935b4..6aca563a77d49c 100644 --- a/examples/chef/devices/rootnode_refrigerator_temperaturecontrolledcabinet_temperaturecontrolledcabinet_ffdb696680.matter +++ b/examples/chef/devices/rootnode_refrigerator_temperaturecontrolledcabinet_temperaturecontrolledcabinet_ffdb696680.matter @@ -424,6 +424,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -432,6 +435,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -442,6 +449,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -475,12 +486,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_roboticvacuumcleaner_1807ff0c49.matter b/examples/chef/devices/rootnode_roboticvacuumcleaner_1807ff0c49.matter index 782bfe9c6e8371..bb860795e719bf 100644 --- a/examples/chef/devices/rootnode_roboticvacuumcleaner_1807ff0c49.matter +++ b/examples/chef/devices/rootnode_roboticvacuumcleaner_1807ff0c49.matter @@ -673,6 +673,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -681,6 +684,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -691,6 +698,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -724,12 +735,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_roomairconditioner_9cf3607804.matter b/examples/chef/devices/rootnode_roomairconditioner_9cf3607804.matter index 77bff3c8eea1a3..0f6984304d7da9 100644 --- a/examples/chef/devices/rootnode_roomairconditioner_9cf3607804.matter +++ b/examples/chef/devices/rootnode_roomairconditioner_9cf3607804.matter @@ -486,6 +486,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -494,6 +497,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -504,6 +511,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -537,12 +548,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_smokecoalarm_686fe0dcb8.matter b/examples/chef/devices/rootnode_smokecoalarm_686fe0dcb8.matter index ed06fdbadaf739..98492723016c84 100644 --- a/examples/chef/devices/rootnode_smokecoalarm_686fe0dcb8.matter +++ b/examples/chef/devices/rootnode_smokecoalarm_686fe0dcb8.matter @@ -673,6 +673,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -681,6 +684,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -691,6 +698,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -724,12 +735,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_speaker_RpzeXdimqA.matter b/examples/chef/devices/rootnode_speaker_RpzeXdimqA.matter index e5ba06a15048b2..24e0be3745fefe 100644 --- a/examples/chef/devices/rootnode_speaker_RpzeXdimqA.matter +++ b/examples/chef/devices/rootnode_speaker_RpzeXdimqA.matter @@ -770,6 +770,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -778,6 +781,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -788,6 +795,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -821,12 +832,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_temperaturesensor_Qy1zkNW7c3.matter b/examples/chef/devices/rootnode_temperaturesensor_Qy1zkNW7c3.matter index 85b38d275b7802..d5abd097d394a8 100644 --- a/examples/chef/devices/rootnode_temperaturesensor_Qy1zkNW7c3.matter +++ b/examples/chef/devices/rootnode_temperaturesensor_Qy1zkNW7c3.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_thermostat_bm3fb8dhYi.matter b/examples/chef/devices/rootnode_thermostat_bm3fb8dhYi.matter index d532d09cd88569..baa51be533f251 100644 --- a/examples/chef/devices/rootnode_thermostat_bm3fb8dhYi.matter +++ b/examples/chef/devices/rootnode_thermostat_bm3fb8dhYi.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/chef/devices/rootnode_windowcovering_RLCxaGi9Yx.matter b/examples/chef/devices/rootnode_windowcovering_RLCxaGi9Yx.matter index f656ebddb7778a..ecb45e1eea68e0 100644 --- a/examples/chef/devices/rootnode_windowcovering_RLCxaGi9Yx.matter +++ b/examples/chef/devices/rootnode_windowcovering_RLCxaGi9Yx.matter @@ -650,6 +650,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -658,6 +661,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -668,6 +675,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -701,12 +712,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/contact-sensor-app/contact-sensor-common/contact-sensor-app.matter b/examples/contact-sensor-app/contact-sensor-common/contact-sensor-app.matter index e112e8f2e73671..ed76b4fe052c54 100644 --- a/examples/contact-sensor-app/contact-sensor-common/contact-sensor-app.matter +++ b/examples/contact-sensor-app/contact-sensor-common/contact-sensor-app.matter @@ -629,6 +629,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -637,6 +640,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -647,6 +654,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -680,12 +691,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/contact-sensor-app/nxp/zap-lit/contact-sensor-app.matter b/examples/contact-sensor-app/nxp/zap-lit/contact-sensor-app.matter index 32f653289ae444..cb540a4824742d 100644 --- a/examples/contact-sensor-app/nxp/zap-lit/contact-sensor-app.matter +++ b/examples/contact-sensor-app/nxp/zap-lit/contact-sensor-app.matter @@ -491,6 +491,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -499,6 +502,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -509,6 +516,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -542,12 +553,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/contact-sensor-app/nxp/zap-sit/contact-sensor-app.matter b/examples/contact-sensor-app/nxp/zap-sit/contact-sensor-app.matter index ae2e6ea4b7b0eb..f7c07ff849ab2f 100644 --- a/examples/contact-sensor-app/nxp/zap-sit/contact-sensor-app.matter +++ b/examples/contact-sensor-app/nxp/zap-sit/contact-sensor-app.matter @@ -491,6 +491,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -499,6 +502,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -509,6 +516,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -542,12 +553,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/dishwasher-app/dishwasher-common/dishwasher-app.matter b/examples/dishwasher-app/dishwasher-common/dishwasher-app.matter index d118b44aed0ac1..81763a112ac05c 100644 --- a/examples/dishwasher-app/dishwasher-common/dishwasher-app.matter +++ b/examples/dishwasher-app/dishwasher-common/dishwasher-app.matter @@ -522,6 +522,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -530,6 +533,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -540,6 +547,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -573,12 +584,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/energy-management-app/energy-management-common/energy-management-app.matter b/examples/energy-management-app/energy-management-common/energy-management-app.matter index 99512288265038..9abd126fa1c683 100644 --- a/examples/energy-management-app/energy-management-common/energy-management-app.matter +++ b/examples/energy-management-app/energy-management-common/energy-management-app.matter @@ -683,6 +683,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -691,6 +694,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -701,6 +708,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -734,12 +745,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/fabric-bridge-app/fabric-bridge-common/fabric-bridge-app.matter b/examples/fabric-bridge-app/fabric-bridge-common/fabric-bridge-app.matter index f776b385bcc383..ca331adef8b9c5 100644 --- a/examples/fabric-bridge-app/fabric-bridge-common/fabric-bridge-app.matter +++ b/examples/fabric-bridge-app/fabric-bridge-common/fabric-bridge-app.matter @@ -466,6 +466,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -474,6 +477,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -484,6 +491,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -517,12 +528,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/laundry-washer-app/nxp/zap/laundry-washer-app.matter b/examples/laundry-washer-app/nxp/zap/laundry-washer-app.matter index ae49f1c25c7bb7..fb8a8c6f57533a 100644 --- a/examples/laundry-washer-app/nxp/zap/laundry-washer-app.matter +++ b/examples/laundry-washer-app/nxp/zap/laundry-washer-app.matter @@ -1007,6 +1007,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1015,6 +1018,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1025,6 +1032,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1058,12 +1069,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/light-switch-app/light-switch-common/light-switch-app.matter b/examples/light-switch-app/light-switch-common/light-switch-app.matter index f5e838972ad2d5..2c8cfc10badd03 100644 --- a/examples/light-switch-app/light-switch-common/light-switch-app.matter +++ b/examples/light-switch-app/light-switch-common/light-switch-app.matter @@ -772,6 +772,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -780,6 +783,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -790,6 +797,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -823,12 +834,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/light-switch-app/qpg/zap/switch.matter b/examples/light-switch-app/qpg/zap/switch.matter index bb43ffe002999a..f5baabdef8ef8b 100644 --- a/examples/light-switch-app/qpg/zap/switch.matter +++ b/examples/light-switch-app/qpg/zap/switch.matter @@ -1095,6 +1095,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1103,6 +1106,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1113,6 +1120,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1146,12 +1157,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/bouffalolab/data_model/lighting-app-ethernet.matter b/examples/lighting-app/bouffalolab/data_model/lighting-app-ethernet.matter index 5b7b85f5857cff..24a8a6e04eba0e 100644 --- a/examples/lighting-app/bouffalolab/data_model/lighting-app-ethernet.matter +++ b/examples/lighting-app/bouffalolab/data_model/lighting-app-ethernet.matter @@ -826,6 +826,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -834,6 +837,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -844,6 +851,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -877,12 +888,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/bouffalolab/data_model/lighting-app-thread.matter b/examples/lighting-app/bouffalolab/data_model/lighting-app-thread.matter index 1fbfa43ce0ab2e..eff1ba235adbcf 100644 --- a/examples/lighting-app/bouffalolab/data_model/lighting-app-thread.matter +++ b/examples/lighting-app/bouffalolab/data_model/lighting-app-thread.matter @@ -826,6 +826,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -834,6 +837,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -844,6 +851,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -877,12 +888,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/bouffalolab/data_model/lighting-app-wifi.matter b/examples/lighting-app/bouffalolab/data_model/lighting-app-wifi.matter index a914ba6caeb62b..38e9e739f88365 100644 --- a/examples/lighting-app/bouffalolab/data_model/lighting-app-wifi.matter +++ b/examples/lighting-app/bouffalolab/data_model/lighting-app-wifi.matter @@ -826,6 +826,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -834,6 +837,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -844,6 +851,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -877,12 +888,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/lighting-common/lighting-app.matter b/examples/lighting-app/lighting-common/lighting-app.matter index 6b50065c4c1c44..55b73e6c35c2ac 100644 --- a/examples/lighting-app/lighting-common/lighting-app.matter +++ b/examples/lighting-app/lighting-common/lighting-app.matter @@ -826,6 +826,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -834,6 +837,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -844,6 +851,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -877,12 +888,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/nxp/zap/lighting-on-off.matter b/examples/lighting-app/nxp/zap/lighting-on-off.matter index c990ea3bbfbde3..c6d8d4cd548a24 100644 --- a/examples/lighting-app/nxp/zap/lighting-on-off.matter +++ b/examples/lighting-app/nxp/zap/lighting-on-off.matter @@ -765,6 +765,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -773,6 +776,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -783,6 +790,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -816,12 +827,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/qpg/zap/light.matter b/examples/lighting-app/qpg/zap/light.matter index 58472a11cb7b1e..82fe03d0f2f725 100644 --- a/examples/lighting-app/qpg/zap/light.matter +++ b/examples/lighting-app/qpg/zap/light.matter @@ -765,6 +765,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -773,6 +776,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -783,6 +790,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -816,12 +827,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/silabs/data_model/lighting-thread-app.matter b/examples/lighting-app/silabs/data_model/lighting-thread-app.matter index a15d472711c218..e641e8276d81c1 100644 --- a/examples/lighting-app/silabs/data_model/lighting-thread-app.matter +++ b/examples/lighting-app/silabs/data_model/lighting-thread-app.matter @@ -826,6 +826,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -834,6 +837,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -844,6 +851,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -877,12 +888,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lighting-app/silabs/data_model/lighting-wifi-app.matter b/examples/lighting-app/silabs/data_model/lighting-wifi-app.matter index 1149a126a222d1..4ae7efa1522d83 100644 --- a/examples/lighting-app/silabs/data_model/lighting-wifi-app.matter +++ b/examples/lighting-app/silabs/data_model/lighting-wifi-app.matter @@ -1085,6 +1085,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1093,6 +1096,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1103,6 +1110,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1136,12 +1147,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lit-icd-app/lit-icd-common/lit-icd-server-app.matter b/examples/lit-icd-app/lit-icd-common/lit-icd-server-app.matter index 3e156b926f6e0c..0f0907e3c1a444 100644 --- a/examples/lit-icd-app/lit-icd-common/lit-icd-server-app.matter +++ b/examples/lit-icd-app/lit-icd-common/lit-icd-server-app.matter @@ -517,6 +517,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -525,6 +528,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -535,6 +542,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -568,12 +579,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lock-app/lock-common/lock-app.matter b/examples/lock-app/lock-common/lock-app.matter index 7dca226d8287b5..c194f5a6983f05 100644 --- a/examples/lock-app/lock-common/lock-app.matter +++ b/examples/lock-app/lock-common/lock-app.matter @@ -793,6 +793,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -801,6 +804,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -811,6 +818,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -844,12 +855,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lock-app/nxp/zap/lock-app.matter b/examples/lock-app/nxp/zap/lock-app.matter index 2aa70597fd5266..5684fdc46361b8 100644 --- a/examples/lock-app/nxp/zap/lock-app.matter +++ b/examples/lock-app/nxp/zap/lock-app.matter @@ -337,6 +337,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -345,6 +348,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -355,6 +362,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -388,12 +399,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/lock-app/qpg/zap/lock.matter b/examples/lock-app/qpg/zap/lock.matter index 79aab6924fe618..5cc5f6f354e883 100644 --- a/examples/lock-app/qpg/zap/lock.matter +++ b/examples/lock-app/qpg/zap/lock.matter @@ -568,6 +568,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -576,6 +579,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -586,6 +593,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -619,12 +630,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/log-source-app/log-source-common/log-source-app.matter b/examples/log-source-app/log-source-common/log-source-app.matter index c07f3c8a8ffad9..c368032f696621 100644 --- a/examples/log-source-app/log-source-common/log-source-app.matter +++ b/examples/log-source-app/log-source-common/log-source-app.matter @@ -157,6 +157,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -165,6 +168,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -175,6 +182,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -208,12 +219,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/microwave-oven-app/microwave-oven-common/microwave-oven-app.matter b/examples/microwave-oven-app/microwave-oven-common/microwave-oven-app.matter index dd7225e9fa102f..3c686228138dfb 100644 --- a/examples/microwave-oven-app/microwave-oven-common/microwave-oven-app.matter +++ b/examples/microwave-oven-app/microwave-oven-common/microwave-oven-app.matter @@ -381,6 +381,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -389,6 +392,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -399,6 +406,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -432,12 +443,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/network-manager-app/network-manager-common/network-manager-app.matter b/examples/network-manager-app/network-manager-common/network-manager-app.matter index e7f55ebbec3808..829518c00e24b0 100644 --- a/examples/network-manager-app/network-manager-common/network-manager-app.matter +++ b/examples/network-manager-app/network-manager-common/network-manager-app.matter @@ -337,6 +337,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -345,6 +348,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -355,6 +362,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -388,12 +399,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/ota-provider-app/ota-provider-common/ota-provider-app.matter b/examples/ota-provider-app/ota-provider-common/ota-provider-app.matter index 9c1bf10d9330c9..52d40b55ac08d6 100644 --- a/examples/ota-provider-app/ota-provider-common/ota-provider-app.matter +++ b/examples/ota-provider-app/ota-provider-common/ota-provider-app.matter @@ -553,6 +553,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -561,6 +564,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -571,6 +578,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -604,12 +615,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/ota-requestor-app/ota-requestor-common/ota-requestor-app.matter b/examples/ota-requestor-app/ota-requestor-common/ota-requestor-app.matter index 055c88a71666e8..f0afcf21730ee4 100644 --- a/examples/ota-requestor-app/ota-requestor-common/ota-requestor-app.matter +++ b/examples/ota-requestor-app/ota-requestor-common/ota-requestor-app.matter @@ -701,6 +701,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -709,6 +712,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -719,6 +726,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -752,12 +763,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/placeholder/linux/apps/app1/config.matter b/examples/placeholder/linux/apps/app1/config.matter index 3b9a3039f30a7a..8d60e86fb52114 100644 --- a/examples/placeholder/linux/apps/app1/config.matter +++ b/examples/placeholder/linux/apps/app1/config.matter @@ -1424,6 +1424,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1432,6 +1435,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1442,6 +1449,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1475,12 +1486,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** This cluster is used to manage global aspects of the Commissioning flow. */ @@ -1493,6 +1515,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1501,6 +1526,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1511,6 +1540,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1544,12 +1577,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/placeholder/linux/apps/app2/config.matter b/examples/placeholder/linux/apps/app2/config.matter index 341c9b5b07d725..002e751eeab930 100644 --- a/examples/placeholder/linux/apps/app2/config.matter +++ b/examples/placeholder/linux/apps/app2/config.matter @@ -1381,6 +1381,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1389,6 +1392,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1399,6 +1406,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1432,12 +1443,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** This cluster is used to manage global aspects of the Commissioning flow. */ @@ -1450,6 +1472,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -1458,6 +1483,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1468,6 +1497,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1501,12 +1534,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/pump-app/pump-common/pump-app.matter b/examples/pump-app/pump-common/pump-app.matter index e915a40a037fe9..bb24649e1d5373 100644 --- a/examples/pump-app/pump-common/pump-app.matter +++ b/examples/pump-app/pump-common/pump-app.matter @@ -709,6 +709,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -717,6 +720,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -727,6 +734,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -760,12 +771,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/pump-app/silabs/data_model/pump-thread-app.matter b/examples/pump-app/silabs/data_model/pump-thread-app.matter index 6b6f7894e5268b..98d3fdbfaa2bee 100644 --- a/examples/pump-app/silabs/data_model/pump-thread-app.matter +++ b/examples/pump-app/silabs/data_model/pump-thread-app.matter @@ -709,6 +709,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -717,6 +720,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -727,6 +734,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -760,12 +771,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/pump-app/silabs/data_model/pump-wifi-app.matter b/examples/pump-app/silabs/data_model/pump-wifi-app.matter index 6b6f7894e5268b..98d3fdbfaa2bee 100644 --- a/examples/pump-app/silabs/data_model/pump-wifi-app.matter +++ b/examples/pump-app/silabs/data_model/pump-wifi-app.matter @@ -709,6 +709,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -717,6 +720,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -727,6 +734,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -760,12 +771,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/pump-controller-app/pump-controller-common/pump-controller-app.matter b/examples/pump-controller-app/pump-controller-common/pump-controller-app.matter index 26ab0343d20e45..58187538be5ba6 100644 --- a/examples/pump-controller-app/pump-controller-common/pump-controller-app.matter +++ b/examples/pump-controller-app/pump-controller-common/pump-controller-app.matter @@ -584,6 +584,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -592,6 +595,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -602,6 +609,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -635,12 +646,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/refrigerator-app/refrigerator-common/refrigerator-app.matter b/examples/refrigerator-app/refrigerator-common/refrigerator-app.matter index 60a01eae22c315..d997c589b9e467 100644 --- a/examples/refrigerator-app/refrigerator-common/refrigerator-app.matter +++ b/examples/refrigerator-app/refrigerator-common/refrigerator-app.matter @@ -374,6 +374,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -382,6 +385,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -392,6 +399,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -425,12 +436,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/rvc-app/rvc-common/rvc-app.matter b/examples/rvc-app/rvc-common/rvc-app.matter index fda431160c3622..c22e5758ba17c1 100644 --- a/examples/rvc-app/rvc-common/rvc-app.matter +++ b/examples/rvc-app/rvc-common/rvc-app.matter @@ -337,6 +337,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -345,6 +348,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -355,6 +362,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -388,12 +399,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/smoke-co-alarm-app/smoke-co-alarm-common/smoke-co-alarm-app.matter b/examples/smoke-co-alarm-app/smoke-co-alarm-common/smoke-co-alarm-app.matter index 346e958ac22fbc..1cfed0b8ce8edc 100644 --- a/examples/smoke-co-alarm-app/smoke-co-alarm-common/smoke-co-alarm-app.matter +++ b/examples/smoke-co-alarm-app/smoke-co-alarm-common/smoke-co-alarm-app.matter @@ -888,6 +888,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -896,6 +899,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -906,6 +913,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -939,12 +950,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/temperature-measurement-app/temperature-measurement-common/temperature-measurement.matter b/examples/temperature-measurement-app/temperature-measurement-common/temperature-measurement.matter index ccf965c8dd2339..f3dec72d7d33c9 100644 --- a/examples/temperature-measurement-app/temperature-measurement-common/temperature-measurement.matter +++ b/examples/temperature-measurement-app/temperature-measurement-common/temperature-measurement.matter @@ -528,6 +528,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -536,6 +539,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -546,6 +553,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -579,12 +590,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/thermostat/nxp/zap/thermostat_matter_thread.matter b/examples/thermostat/nxp/zap/thermostat_matter_thread.matter index 3cf062b03c6d2e..6d322db15086c3 100644 --- a/examples/thermostat/nxp/zap/thermostat_matter_thread.matter +++ b/examples/thermostat/nxp/zap/thermostat_matter_thread.matter @@ -985,6 +985,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -993,6 +996,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1003,6 +1010,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1036,12 +1047,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/thermostat/nxp/zap/thermostat_matter_wifi.matter b/examples/thermostat/nxp/zap/thermostat_matter_wifi.matter index f3065011d62972..2c68853b854ad9 100644 --- a/examples/thermostat/nxp/zap/thermostat_matter_wifi.matter +++ b/examples/thermostat/nxp/zap/thermostat_matter_wifi.matter @@ -985,6 +985,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -993,6 +996,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -1003,6 +1010,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -1036,12 +1047,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/thermostat/qpg/zap/thermostaticRadiatorValve.matter b/examples/thermostat/qpg/zap/thermostaticRadiatorValve.matter index a51d01dc8b2633..609460644955c3 100644 --- a/examples/thermostat/qpg/zap/thermostaticRadiatorValve.matter +++ b/examples/thermostat/qpg/zap/thermostaticRadiatorValve.matter @@ -665,6 +665,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -673,6 +676,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -683,6 +690,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -716,12 +727,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/thermostat/thermostat-common/thermostat.matter b/examples/thermostat/thermostat-common/thermostat.matter index e63ebeba6df9ae..800182f38d0c67 100644 --- a/examples/thermostat/thermostat-common/thermostat.matter +++ b/examples/thermostat/thermostat-common/thermostat.matter @@ -726,6 +726,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -734,6 +737,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -744,6 +751,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -777,12 +788,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/tv-app/tv-common/tv-app.matter b/examples/tv-app/tv-common/tv-app.matter index ffc1c6a8ebaaf6..7c50f77e8647ab 100644 --- a/examples/tv-app/tv-common/tv-app.matter +++ b/examples/tv-app/tv-common/tv-app.matter @@ -689,6 +689,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -697,6 +700,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -707,6 +714,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -740,12 +751,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** This cluster is used to manage global aspects of the Commissioning flow. */ @@ -758,6 +780,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -766,6 +791,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -776,6 +805,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -809,12 +842,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/tv-casting-app/tv-casting-common/tv-casting-app.matter b/examples/tv-casting-app/tv-casting-common/tv-casting-app.matter index 06fba3e02f952a..5dad7807038b48 100644 --- a/examples/tv-casting-app/tv-casting-common/tv-casting-app.matter +++ b/examples/tv-casting-app/tv-casting-common/tv-casting-app.matter @@ -773,6 +773,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -781,6 +784,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -791,6 +798,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -824,12 +835,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/virtual-device-app/virtual-device-common/virtual-device-app.matter b/examples/virtual-device-app/virtual-device-common/virtual-device-app.matter index 0a5e801e302ad2..cc933041a0b6d5 100644 --- a/examples/virtual-device-app/virtual-device-common/virtual-device-app.matter +++ b/examples/virtual-device-app/virtual-device-common/virtual-device-app.matter @@ -929,6 +929,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -937,6 +940,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -947,6 +954,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -980,12 +991,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/examples/window-app/common/window-app.matter b/examples/window-app/common/window-app.matter index ca06461be78396..f95b050278e64b 100644 --- a/examples/window-app/common/window-app.matter +++ b/examples/window-app/common/window-app.matter @@ -914,6 +914,9 @@ cluster GeneralCommissioning = 48 { kInvalidAuthentication = 2; kNoFailSafe = 3; kBusyWithOtherAdmin = 4; + kRequiredTCNotAccepted = 5; + kTCAcknowledgementsNotReceived = 6; + kTCMinVersionNotMet = 7; } enum RegulatoryLocationTypeEnum : enum8 { @@ -922,6 +925,10 @@ cluster GeneralCommissioning = 48 { kIndoorOutdoor = 2; } + bitmap Feature : bitmap32 { + kTermsAndConditions = 0x1; + } + struct BasicCommissioningInfo { int16u failSafeExpiryLengthSeconds = 0; int16u maxCumulativeFailsafeSeconds = 1; @@ -932,6 +939,10 @@ cluster GeneralCommissioning = 48 { readonly attribute RegulatoryLocationTypeEnum regulatoryConfig = 2; readonly attribute RegulatoryLocationTypeEnum locationCapability = 3; readonly attribute boolean supportsConcurrentConnection = 4; + provisional readonly attribute access(read: administer) optional int16u TCAcceptedVersion = 5; + provisional readonly attribute access(read: administer) optional int16u TCMinRequiredVersion = 6; + provisional readonly attribute access(read: administer) optional bitmap16 TCAcknowledgements = 7; + provisional readonly attribute access(read: administer) optional boolean TCAcknowledgementsRequired = 8; readonly attribute command_id generatedCommandList[] = 65528; readonly attribute command_id acceptedCommandList[] = 65529; readonly attribute event_id eventList[] = 65530; @@ -965,12 +976,23 @@ cluster GeneralCommissioning = 48 { char_string debugText = 1; } + request struct SetTCAcknowledgementsRequest { + int16u TCVersion = 0; + bitmap16 TCUserResponse = 1; + } + + response struct SetTCAcknowledgementsResponse = 7 { + CommissioningErrorEnum errorCode = 0; + } + /** Arm the persistent fail-safe timer with an expiry time of now + ExpiryLengthSeconds using device clock */ command access(invoke: administer) ArmFailSafe(ArmFailSafeRequest): ArmFailSafeResponse = 0; /** Set the regulatory configuration to be used during commissioning */ command access(invoke: administer) SetRegulatoryConfig(SetRegulatoryConfigRequest): SetRegulatoryConfigResponse = 2; /** Signals the Server that the Client has successfully completed all steps of Commissioning/Recofiguration needed during fail-safe period. */ fabric command access(invoke: administer) CommissioningComplete(): CommissioningCompleteResponse = 4; + /** This command sets the user acknowledgements received in the Enhanced Setup Flow Terms and Conditions into the node. */ + command access(invoke: administer) SetTCAcknowledgements(SetTCAcknowledgementsRequest): SetTCAcknowledgementsResponse = 6; } /** Functionality to configure, enable, disable network credentials and access on a Matter device. */ diff --git a/src/app/zap-templates/zcl/data-model/chip/general-commissioning-cluster.xml b/src/app/zap-templates/zcl/data-model/chip/general-commissioning-cluster.xml index eabc56a4d95916..da813b60fef2e4 100644 --- a/src/app/zap-templates/zcl/data-model/chip/general-commissioning-cluster.xml +++ b/src/app/zap-templates/zcl/data-model/chip/general-commissioning-cluster.xml @@ -1,6 +1,6 @@