Gateway issue/incompatibility: NORD is 0 #3

Open
klauer opened this issue Jun 1, 2021 · 2 comments
Open

Gateway issue/incompatibility: NORD is 0 #3

klauer opened this issue Jun 1, 2021 · 2 comments

Comments

@klauer
Copy link
Contributor

klauer commented Jun 1, 2021

Per @ZLLentz's summary of the long-standing issue:

camviewer uses the NORD field to get the number of active elements in the array to monitor, but the gateway sometimes bugs out and reports it as zero
area detector image streams initialize as 0 by 0 before receiving any frames, and this also does not play well with the loading of the blank image

@ZLLentz
Copy link
Member

ZLLentz commented Jun 3, 2021

One more gateway incompatibility:
if a gateway is having a bad day, it will take longer than 1s to read the array data, leading to an error in camviewer instead of just a really laggy image

@klauer
Copy link
Contributor Author

klauer commented Jun 3, 2021

Long-term, I wonder if we should consider moving the data source from CA to Kafka or less preferably PVA? This sort of consistency issue is just non-existent there.