The cooling tables in the repository are inconsistent with the convention expected by AthenaPK (#97).

https://github.com/parthenon-hpc-lab/athenapk/tree/main/inputs/cooling_tables

For temperatures about $10^{5.5}$ K where CIE is valid, this causes a 10-20% discrepancy in expected vs. actual cooling rate.

@BenWibking
Copy link
Contributor Author

Fixed by #97.