You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Fantastic work on the camera program. I'm using it to try to generate data to support some changes to the local road infrastructure. But I'm after a little configuration help.
The camera is working well in general but is misreading on large vehicles producing anomalous high results i.e. farm tractor with trailer being detected at 150mph and large vans at 90mph.
I've had to play with the settings to get the camera to detect vehices in the speed range at the site (20-110mph) and I think that somewhere I've allowed in this misreading in trying to accomodate higher speeds.
Setup is a RP4 2Gb with a PiNoir camera running the 720 plugin.
P.S. As a request is there a facility to expoit the CSV data? The data would be very useful to communities trying to evidence speeding problems but there is no easy export option. TIA
`# Motion Event Settings
---------------------
MO_TRACK_EVENT_COUNT = 6 # Default= 6 Number of Consecutive Motion Events to>
# Suggest single core cpu=4-7 quad core=8-15 but ad>
MO_MIN_AREA_PX = 500 # Default= 200 Exclude all contours less than or eq>
MO_LOG_OUT_RANGE_ON = False # Default= True Show Out of Range Events per x_dif>
MO_MAX_X_DIFF_PX = 650 # Default= 20 Exclude if max px away >= last motio>
MO_MIN_X_DIFF_PX = 55 # Default= 1 Exclude if min px away <= last event >
MO_X_LR_SIDE_BUFF_PX = 10 # Default= 10 Divides motion Rect x for L&R Buffer >
MO_TRACK_TIMEOUT_SEC = 0.5 # Default= 0.5 Optional seconds to wait after track>
MO_EVENT_TIMEOUT_SEC = 0.2 # Default= 0.3 seconds to wait for next motion even>
MO_MAX_SPEED_OVER = 37`
The text was updated successfully, but these errors were encountered:
Hi there, I can't help with your high numbers but you can view .csv files by using the ./menubox command in a terminal. Then you just choose 'g'. I have exported them as well, so let me see how. (Edited)
OK, so the .csv file should be located at: /speed-camera. You can copy that to your local machine and view it there.
P.S. As a request is there a facility to expoit the CSV data? The data would be very useful to communities trying to evidence speeding problems but there is no easy export option. TIA
If you run the webserver you can symlink the csv into the media directory and download it from there whenever you want.
This assumes your install is in the default location.
cd~/speed-camera/media
ln -s ../speed-cam.csv
I would not recommend exposing this on the internet unprotected, but it is useful for someone on the same network as the pi.
You can also use this branch to send the data and image wherever you want.
Hello,
Fantastic work on the camera program. I'm using it to try to generate data to support some changes to the local road infrastructure. But I'm after a little configuration help.
The camera is working well in general but is misreading on large vehicles producing anomalous high results i.e. farm tractor with trailer being detected at 150mph and large vans at 90mph.
I've had to play with the settings to get the camera to detect vehices in the speed range at the site (20-110mph) and I think that somewhere I've allowed in this misreading in trying to accomodate higher speeds.
Setup is a RP4 2Gb with a PiNoir camera running the 720 plugin.
P.S. As a request is there a facility to expoit the CSV data? The data would be very useful to communities trying to evidence speeding problems but there is no easy export option. TIA
`# Motion Event Settings
---------------------
MO_TRACK_EVENT_COUNT = 6 # Default= 6 Number of Consecutive Motion Events to>
# Suggest single core cpu=4-7 quad core=8-15 but ad>
MO_MIN_AREA_PX = 500 # Default= 200 Exclude all contours less than or eq>
MO_LOG_OUT_RANGE_ON = False # Default= True Show Out of Range Events per x_dif>
MO_MAX_X_DIFF_PX = 650 # Default= 20 Exclude if max px away >= last motio>
MO_MIN_X_DIFF_PX = 55 # Default= 1 Exclude if min px away <= last event >
MO_X_LR_SIDE_BUFF_PX = 10 # Default= 10 Divides motion Rect x for L&R Buffer >
MO_TRACK_TIMEOUT_SEC = 0.5 # Default= 0.5 Optional seconds to wait after track>
MO_EVENT_TIMEOUT_SEC = 0.2 # Default= 0.3 seconds to wait for next motion even>
MO_MAX_SPEED_OVER = 37`