2.5.3.20200604
- fix PVOUTPUT error 503 if no connection
- fix MQTT Timeout
- fix Hybrid detection
- fix QPIGS Description typo
- fix MQTT Bulk and Float where wrong
- new BMV 600S support Experimental
- added Pylontech battery temperature values MQTT
- added Pylontech ammount of Packs MQTT
- added change charge values with MQTT 50A and 60A
-
2.5.0.20200501
- NEW #26 pylon support
- pylon values send to Emoncms through MQTT.
- rs232 parser rewritten
- #40 MQTT try to connect every 10 seconds if internet/wifi down
- hybrid P18 daily values sent through MQTT
- new status values pip/masterstatus and pip/status2
- more BMV values sent
- rearangement of interface
- config file not backwards compatible
- logging to emoncms with node and name. you are free to choose name at which emoncms is displaying. Not tied to the serialnumber
- for backwards compatiblity you may insert the inverter serial number in the name fiels at the "config->logging" separator
- for values sent over MQTT see README
- Hybrid P17 P18 rewritten
-
2.4.0.20200313
- new check both hybrid inverter and send data over MQTT
- new change status to eco aut online on KING inverter with "solpiplog/pip/status/set" and payload eco,aut,onl
- new pylon support ( implementing. disabled, testing in curse )
- new chage charge status with "solpiplog/pip/charge/set" and payload 0,1,2,3
- reading of current status with "solpiplog/pip/status" and charge with "solpiplog/pip/charge"
- bugfix MQTT connection not starting at boot.
- bugfixes
-
2.3.1.20200118
- bugfix save MQTT user and password on reboot
- bugfix send MQTT if only bmv connected
- able to change MQTT prefix. Usefull for logging more than one Inverter
- NEW change inverter status and charge status with MQTT
-
2.3.0.20191013
- NEW send status of ECO and Bypass for KING inverter at key 25 and 26
- bugfix logging node with rs232 interface with KING inverter was not working.
-
2.3.0 Gandalf release
- NEW sending MQTT with user and password possible
- NEW logging multiple USB inverters possible ( copy new solpiplog.rules to udev folder )
- on raspberry at ( /etc/udev/rules.d )
-
2.3.0.20191005
- bugfix inverter with multiple MPPT not logging the aditional MPPT
-
2.2.5.20190802
- added new values to send over MQTT
-
2.2.5.20190726
- bugfix not sending data to emoncms.org
- new change charge priority by timewindow
- added source priority change SOL
- fixed typos
- working on raspberry zero and A+
-
2.2.2 05/2019
- NEW BMV 712 Smart support
- NEW MQTT Port possible to change
- bugfix MPPT2 not logging
- bugfix Hybrid not logging
-
2.2.1 * prerelease
- bugfix parallel inverter not logging
- added key P15 PV Voltage for parallel inverter
-
2.2.0 * 2019 mqtt, Switch by time, log BMV only
-
2.1.1 * bug mppt2 version not logging * bug mppt2 version logging with node and serialnumber * choose from inverter single parallel or hybrid
-
2.1.0 * new hybrid version support
-
2.0.4 * save with Node or Serialnumber
-
2.0.3 * new BMV param H17 H18 send on Node 20 Key 13 and 14
-
2.0.2 * bug parallel connections with bad/delayed internet connection *bug udp need to uncheck and check to begin sending. *new on autostart minimize solpiplog *new send UDP datagram for parallel versions
-
2.0.1 * bug error on delayed/bad internet connections error output
-
2.0.0 * Phoenix version
- support for parallel inverter reading 4 at once
- ability to change node
- layout changed. cosmetic alterations.
-
1.5.0 * Primavera version
- support for Inverter with 2 MPPT
- logs aditional parameter for BMV702
- Sends UDP datagramm to a Server / for example to a Loxone Smart Home server
- autoload config and Start possible.
- bug crc errors solved
- solved timeout on 2MPPT versions solved
-
1.4.9a* rik_man UDP version
-
1.4.9 * tealc_hr internal forum release
-
1.4.8 * 03/2017 new change BULK and FLOAT
-
1.4.7 * Vollkorn changed how to Switch to UTI/SOL.
-
1.4.6 * BennyHH BMV logging without PIP online
-
1.4.5 * agenturrene v4 change charger priority
-
1.4.4 * agenturrene v3 switching SOC error
-
1.4.3 * agenturrene v2 faster bmv detection
-
1.4.2 * agenturrene v1 two MPPT version
-
1.4.1 * 11/2016 RS232 public release
- change on SOC activated.
- Changes inverter to UTI or SBU based on SOC
-
1.4.0 * Vollkorn release RS232 support for Inverter
- bugfixes, layout changed.
-
1.3.1 * BennyHH Soc version internal release
-
1.3.0 * 10/2016 NEW BMV Battery Monitor log parameter send to EmonCMS on Node 20
- Key 1 : Battery voltage mV
- Key 2 : Battery current mA
- Key 3 : Instantaneous Power W
- Key 4 : Consumed Amp Hours mAh
- Key 5 : State-of-Charge
- Key 6 : Time-to-go in minutes
- Key 8 : Alarm status ON/OFF
- Key 25: Relay status ON/OFF
-
1.2.6 * BennyHH v3 internal test
- new parameter 30 : Year
- new parameter 31 : Month
- new parameter 32 : Day
- new parameter 33 : Hour
- new parameter 34 : Minute
- new parameter 35 : Seconds
-
1.2.5 * BennyHH v2 internal test
- Added parameter 18 Line Mode
- Added parameter 19 Battery Mode
- Added parameter 20 Fault Mode
- add detection if internet connection available
-
1.2.4 * bug timer overflow
- changes on workflow for slow machines
- rewritten parser
- cosmetic changes
- raspberry 2 version adaptation
- a lot of bugs removed
-
1.2.3.alpha - BennyHH version
-
1.2.2 - * bug timeout problems on slow machines increased to 5 seconds
- log screen . showing all errors.
-
1.2.1 - removed change by watt ( debug version )
- updated logo
- bug* Connect button without focus after clicking manual Disconnect
-
1.2 - fist public release