The Ventilation Unit is seperated into multiple Units, and sometimes even SubUnits. Here is a list of some existing units:

ID # of SubUnits Name Responsible for
0x01 1 NODE Represents the general node with attributes like serial nr, etc.
0x02 1 COMFOBUS Unit responsible for comfobus-communication. Probably stores the ID's of connected devices.
0x03 1 ERROR Stores errors, allows errors to be reset
0x15 10 SCHEDULE Responsible for managing Timers, the schedule, etc. Check here for level, bypass etc.
0x16 2 VALVE ??? Bypass PreHeater and Extract
0x17 2 FAN Represents the two fans (supply, exhaust)
0x18 1 POWERSENSOR Counts the actual wattage of ventilation and accumulates to year and since factory reset
0x19 1 PREHEATER Represents the optional preheater
0x1A 1 HMI Represents the Display + Buttons
0x1B 1 RFCOMMUNICATION Wireless-communication with attached devices
0x1C 1 FILTER Counts the days since last filter change
0x1D 1 TEMPHUMCONTROL Controls the target temperature, if its cooling or heating period and some settings
0x1E 1 VENTILATIONCONFIG Responsible for managing various configuration options of the ventilation
0x20 1 NODECONFIGURATION Manages also some options
0x21 6 TEMPERATURESENSOR Represents the 6 temperature sensors in the ventilation
0x22 6 HUMIDITYSENSOR Represents the 6 humidity sensors
0x23 2 PRESSURESENSOR Represents both pressure sensors
0x24 1 PERIPHERALS Stores the ID of the ComfoCool attached, can reset peripheral errors here
0x25 4 ANALOGINPUT Provides data and functionality for the analog inputs, also the scaling for the voltages
0x26 1 COOKERHOOD "Dummy" unit, probably represents the ComfoHood if attached
0x27 1 POSTHEATER Represents the optional post heater attached (temperature sens, config)
0x28 1 COMFOFOND "Dummy" unit, represents the optional comfofond

Error codes

If an error occurs the reason can be one of the following:

Number Description
11 Unknown Command
12 Unknown Unit
13 Unknown SubUnit
14 Unknown property
15 Type can not have a range
30 Value given not in Range
32 Property not gettable or settable
40 Internal error
41 Internal error, maybe your command is wrong

General commands

There are three commands which always exist on a given Unit:

  • 0x01: Get a single property

    This command reads a single property identified by the Unit, SubUnit and Property.

    Syntax: 01 Unit SubUnit Type Property

    The Type can be one of the following:

    • 0x00: None
    • 0x10: Actual value
    • 0x20: Range
    • 0x40: Step size

    Each writable property may have a range & step size. You can get those values by using the 0x20 and 0x40 Type values. You can request multiple types at the same time by OR'ing the value.

    Example: Request: 01 20 01 10 03, Response: 34 32 31 30 00 (4210\0) This gets the maintainer password. Unit is NODECONFIGURATION, SubUnit is 01, get the actual value, Property 03.

  • 0x02: Get multiple properties

    This command allows to read multiple properties in one request.

    Syntax: 02 Unit SubUnit 01 Type Property1 Property2 ... PropertyN

    The Type value needs to be OR'ed with the number of properties. So if you want to read the actual value of 5 properties, the Type value needs to be 0x10 | 0x05 = 0x15.

    Example: Request: 02 01 01 01 15 03 04 06 05 14, Response: \02 BEA000000000000\00 \00\10\10\c0 \02 ComfoAirQ\00 This reads the following property values:

    • 0x03: ???
    • 0x04: Serial Number
    • 0x06: Firmware version
    • 0x05: ???
    • 0x14: Ventilation Unit Name
  • 0x03: Set a single property

    This commands sets one property to the given value. The value needs to be in the range as identified within 0x01, otherwise an error of 30 is returned. The step size, however, is not checked.

    Syntax: 03 Unit SubUnit Property Value

    Example: 03 1D 01 04 00 Unit is TEMPHUMCONTROL, SubUnit 01, Property: 04, value 00 Sets the Property "Sensor ventilation: Temperature passive" to off

All other commands are >= 0x80 and dependent on the SubUnit. Please do not try to run command 0x80, 0x82 on NODECONFIGURATION (0x20), they will probably break your configuration, and even worse would be calling ANY >= 0x80 command on NODE (0x01). It can probably completely brick your ventilation. (It enters factory mode or tries to perform an update.)

Known properties for Node 0x01 (Ventilation Unit)

Unit SubUnit Property Access Format Description
NODE 0x01 0x01 UINT8 ?? 01 = 1
NODE 0x01 0x02 UINT8 ?? 01 = 1
NODE 0x01 0x03 UINT8 ?? 02 = 2
NODE 0x01 0x04 ro STRING Serial number (BEA009999999999)
NODE 0x01 0x05 UINT8 ?? 02 = 2
NODE 0x01 0x06 ro UINT32 Firmware version (See version_decode())
NODE 0x01 0x07 UINT32 ?? 00541040 = 1074811904
NODE 0x01 0x08 ro STRING Model number (ComfoAir Q450 B R RF ST Quality)
NODE 0x01 0x09 UINT32 ?? 04000000 = 4
NODE 0x01 0x0A UINT32 ?? 0004f0c0 = 3236955136
NODE 0x01 0x0B ro STRING Article number (471502004)
NODE 0x01 0x0C STRING ?? NULL
NODE 0x01 0x0D ro STRING Current Country (BE)
NODE 0x01 0x14 ro STRING Ventilation Unit Name (ComfoAirQ)
TEMPHUMCONTROL 0x01 0x01 UINT8 ?? 01 = 1
TEMPHUMCONTROL 0x01 0x02 rw INT16 RMOT for heating period (180 -> 18°C)
TEMPHUMCONTROL 0x01 0x03 rw INT16 RMOT for cooling period (200 -> 20°C)
TEMPHUMCONTROL 0x01 0x04 rw UINT8 Passive temperature control (0=off, 1=autoonly, 2=on)
TEMPHUMCONTROL 0x01 0x05 rw UINT8 ?? 00 = 0
TEMPHUMCONTROL 0x01 0x06 rw UINT8 Humidity comfort control (o=off, 1=autoonly, 2=on)
TEMPHUMCONTROL 0x01 0x07 rw UINT8 Humidity protection (0=off, 1=autoonly, 2=on)
TEMPHUMCONTROL 0x01 0x08 rw UINT8 ?? 00 = 0
TEMPHUMCONTROL 0x01 0x0A rw INT16 Target temperature for profile: Heating (230 -> 23°C)
TEMPHUMCONTROL 0x01 0x0B rw INT16 Target temperature for profile: Normal (210 -> 21°C)
TEMPHUMCONTROL 0x01 0x0C rw INT16 Target temperature for profile: Cooling (190 -> 19°C)
TEMPHUMCONTROL 0x01 0x0D UINT8 ?? 00 = 0
VENTILATIONCONFIG 0x01 0x01 UINT8 ?? 01 = 1
VENTILATIONCONFIG 0x01 0x02 UINT8 ?? 0f = 15
VENTILATIONCONFIG 0x01 0x03 rw INT16 Ventilation speed in "Away" Level (75)
VENTILATIONCONFIG 0x01 0x04 rw INT16 Ventilation speed in "Low" Level (110)
VENTILATIONCONFIG 0x01 0x05 rw INT16 Ventilation speed in "Medium" Level (180)
VENTILATIONCONFIG 0x01 0x06 rw INT16 Ventilation speed in "High" Level (370)
VENTILATIONCONFIG 0x01 0x07 UINT8 Height above sea level (0=0-500, 1=500-1000, 2=1000-1500, 3=1500-2000)
VENTILATIONCONFIG 0x01 0x08 INT16 ?? 8b01 = 395,420
VENTILATIONCONFIG 0x01 0x09 UINT8 Ventilation control mode (0=flow control, 1=constant flow)
VENTILATIONCONFIG 0x01 0x0a INT16 ?? ecff = -20
VENTILATIONCONFIG 0x01 0x0b INT16 Bathroom switch, activation delay (300 = 300 sec)
VENTILATIONCONFIG 0x01 0x0c UINT8 Bathroom switch, deactivation delay (30 = 30 min)
VENTILATIONCONFIG 0x01 0x0d UINT8 Bathroom switch, mode (0=fixed, 1=mirrored)
VENTILATIONCONFIG 0x01 0x0e UINT8 ?? 03 = 3
VENTILATIONCONFIG 0x01 0x0f UINT8 ?? 00 = 0
VENTILATIONCONFIG 0x01 0x11 INT16 ?? c800 = 200
VENTILATIONCONFIG 0x01 0x12 INT16 Unbalance (9dff = -99 -> -9.9)
VENTILATIONCONFIG 0x01 0x13 INT16 ?? 0000 = 0
VENTILATIONCONFIG 0x01 0x14 INT16 ?? 0000 = 0
VENTILATIONCONFIG 0x01 0x15 INT16 ?? 980d = 3480
VENTILATIONCONFIG 0x01 0x16 INT16 ?? 660c = 3174
VENTILATIONCONFIG 0x01 0x17 INT16 ?? 0000 = 0
VENTILATIONCONFIG 0x01 0x18 INT16 ?? 0000 = 0
VENTILATIONCONFIG 0x01 0x19 INT16 ?? 8107 = 1921
VENTILATIONCONFIG 0x01 0x1a INT16 ?? a106 = 1697
VENTILATIONCONFIG 0x01 0x1b INT16 ?? 0f05 = 1295
VENTILATIONCONFIG 0x01 0x1c INT16 ?? 0c05 = 1292
VENTILATIONCONFIG 0x01 0x1d INT16 ?? 5304 = 1107
VENTILATIONCONFIG 0x01 0x1e INT16 ?? 1304 = 1043
NODECONFIGURATION 0x01 0x01 UINT8 ?? 01 = 1
NODECONFIGURATION 0x01 0x03 STRING Maintainer password (NL=4210, BE=2468, DE=4210)
NODECONFIGURATION 0x01 0x04 UINT8 Orientation (0=left, 1=right)
NODECONFIGURATION 0x01 0x05 UINT8 ?? 01 = 1
NODECONFIGURATION 0x01 0x06 UINT8 ?? 00 = 0
NODECONFIGURATION 0x01 0x07 UINT8 ?? 00 = 0
NODECONFIGURATION 0x01 0x08 UINT8 ?? 01 = 1
NODECONFIGURATION 0x01 0x0A UINT8 ?? 00 = 0
NODECONFIGURATION 0x01 0x0B UINT8 ?? 02 = 2
NODECONFIGURATION 0x01 0x0C UINT8 ?? 01 = 1

Known properties for Node 0x30 (ComfoConnect LAN C)

Unit SubUnit Property Access Format Description
NODE 0x01 0x01 UINT8 ?? ff = 255
NODE 0x01 0x02 UINT8 ?? 05 = 5
NODE 0x01 0x03 UINT8 ?? 00 = 0
NODE 0x01 0x04 ro STRING Serial number (DEM0999999999)
NODE 0x01 0x05 UINT8 ?? 01 = 1
NODE 0x01 0x06 ro UINT32 Firmware version (See version_decode())
NODE 0x01 0x07 UINT32 ?? 008c10c0 = 3222309888
NODE 0x01 0x14 ro STRING Unit Name (ComfoConnect LAN C)

SCHEDULE Unit commands

  • 0x80: GETSCHEDULEENTRY
  • 0x81: ENABLESCHEDULEENTRY
  • 0x82: DISABLESCHEDULEENTRY
  • 0x83: GETTIMERENTRY
  • 0x84: ENABLETIMERENTRY
  • 0x85: DISABLETIMERENTRY
  • 0x86: GETSCHEDULE
  • 0x87: GETTIMERS

Known schedules

SubUnit Property Description
0x01 0x01 Preset (00=away/01=low/02=medium/03=high)
0x01 0x02 PRESETRF
0x01 0x03 PRESETANALOG
0x01 0x04 PRESETRFANALOG
0x01 0x05 MANUALMODE
0x01 0x06 BOOST
0x01 0x07 BOOSTRF
0x01 0x08 BOOSTSWITCH
0x01 0x0b AWAY
0x02 0x01 Bypass control (auto/on/off)
0x03 0x01 Temperature profile (warm/normal/cool)
0x05 0x01 Comfocool control
0x06 0x01 Supply fan control
0x07 0x01 Exhaust fan control
0x08 0x01 Ventilation mode (auto/manual)

ERROR Unit commands

  • 0x80: GETACTIVEERRORS
  • 0x82: RESETALLERRORS

Error list

Error ID Description
21 DANGER! OVERHEATING! Two or more sensors are detecting an incorrect temperature. Ventilation has stopped.
22 Temperature too high for ComfoAir Q (TEMP_HRU ERROR)
23 The extract air temperature sensor has a malfunction (SENSOR_ETA ERROR)
24 The extract air temperature sensor is detecting an incorrect temperature (TEMP_SENSOR_ETA ERROR)
25 The exhaust air temperature sensor has a malfunction (SENSOR_EHA ERROR)
26 The exhaust air temperature sensor is detecting an incorrect temperature (TEMP_SENSOR_EHA ERROR)
27 The outdoor air temperature sensor has a malfunction (SENSOR_ODA ERROR)
28 The outdoor air temperature sensor is detecting an incorrect temperature (TEMP_SENSOR_ODA ERROR)
29 The pre-conditioned outdoor air temperature sensor has a malfunction
30 The pre-conditioned outdoor air temperature sensor is detecting an incorrect temperature (TEMP_SENSOR_P-ODA ERROR)
31 The supply air temperature sensor has a malfunction (SENSOR_SUP ERROR)
32 The supply air temperature sensor is detecting an incorrect temperature (TEMP_SENSOR_SUP ERROR)
33 The Ventilation Unit has not been commissioned (INIT ERROR)
34 The front door is open
35 The Pre-heater is present, but not in the correct position (right/left). (PREHEAT_LOCATION ERROR)
37 The pre-heater has a malfunction (PREHEAT ERROR)
38 The pre-heater has a malfunction (PREHEAT ERROR)
39 The extract air humidity sensor has a malfunction (SENSOR_ETA ERROR)
41 The exhaust air humidity sensor has a malfunction (SENSOR_EHA ERROR)
43 The outdoor air humidity sensor has a malfunction (SENSOR_ODA ERROR)
45 The outdoor air humidity sensor has a malfunction (SENSOR_P-ODA ERROR)
47 The supply air humidity sensor has a malfunction (SENSOR_SUP ERROR)
49 The exhaust air flow sensor has a malfunction (SENSOR_EHA ERROR)
50 The supply air flow sensor has a malfunction (SENSOR_SUP ERROR)
51 The extract air fan has a malfunction (FAN_EHA ERROR)
52 The supply air fan has a malfunction (FAN_SUP ERROR)
53 Exhaust air pressure too high. Check air outlets, ducts and filters for pollution and obstructions. Check valve settings (EXT_PRESSURE_EHA ERROR)
54 Supply air pressure too high. Check air outlets, ducts and filters for pollution and obstructions. Check valve settings. (EXT_PRESSURE_SUP ERROR)
55 The extract air fan has a malfunction (FAN_EHA ERROR)
56 The supply air fan has a malfunction (FAN_SUP ERROR)
57 The exhaust air flow is not reaching its set point (AIRFLOW_EHA ERROR)
58 The supply air flow is not reaching its set point (AIRFLOW_SUP ERROR)
59 Failed to reach required temperature too often for outdoor air after pre-heater (TEMPCONTROL_P-ODA ERROR)
60 Failed to reach required temperature too often for supply air. The modulating by-pass may have a malfunction. (TEMPCONTROL_SUP ERROR)
61 Supply air temperature is too low too often (TEMP_SUP_MIN ERROR)
62 Unbalance occurred too often beyond tolerance levels in past period (UNBALANCE ERROR)
63 Postheater was present, but is no longer detected (POSTHEAT_CONNECT ERROR)
64 Temperature sensor value for supply air ComfoCool exceeded limit too often (CCOOL_TEMP ERROR)
65 Room temperature sensor was present, but is no longer detected (T_ROOM_PRES ERROR)
66 RF Communication hardware was present, but is no longer detected (RF_PRES ERROR)
67 Option Box was present, but is no longer detected (OPTION_BOX CONNECT ERROR)
68 Pre-heater was present, but is no longer detected (PREHEAT_PRES ERROR)
69 Postheater was present, but is no longer detected (POSTHEAT_CONNECT ERROR)
# Firmware 1.4.0+
70 Analog input 1 was present, but is no longer detected (ANALOG_1_PRES ERROR)
71 Analog input 2 was present, but is no longer detected (ANALOG_2_PRES ERROR)
72 Analog input 3 was present, but is no longer detected (ANALOG_3_PRES ERROR)
73 Analog input 4 was present, but is no longer detected (ANALOG_4_PRES ERROR)
74 ComfoHood was present, but is no longer detected (HOOD_CONNECT ERROR)
75 ComfoCool was present, but is no longer detected (CCOOL_CONNECT ERROR)
76 ComfoFond was present, but is no longer detected (GROUND_HEAT_CONNECT ERROR)
77 The filters of the Ventilation Unit must be replaced now
78 It is necessary to replace or clean the external filter
79 Order new filters now, because the remaining filter life time is limited
80 Service mode is active (SERVICE MODE)
81 Preheater has no communication with the ComfoAir unit (PREHEAT ERROR , 1081)
82 ComfoHood temperature error (HOOD_TEMP ERROR)
83 Postheater temperature error (POSTHEAT_TEMP ERROR)
84 Outdoor temperature of ComfoFond error (GROUND_HEAT_TEMP ERROR)
85 Analog input 1 error (ANALOG_1_IN ERROR)
86 Analog input 2 error (ANALOG_2_IN ERROR)
87 Analog input 3 error (ANALOG_3_IN ERROR)
88 Analog input 4 error (ANALOG_4_IN ERROR)
89 Bypass is in manual mode
90 ComfoCool is overheating
91 ComfoCool compressor error (CCOOL_COMPRESSOR ERROR)
92 ComfoCool room temperature sensor error (CCOOL_TEMP ERROR)
93 ComfoCool condensor temperature sensor error (CCOOL_TEMP ERROR)
94 ComfoCool supply air temperature sensor error (CCOOL_TEMP ERROR)
95 ComfoHood temperature is too high (HOOD_TEMP ERROR)
96 ComfoHood is activated
97 UNKNOWN: QM_Constraint_min_ERR
98 UNKNOWN: H_21_qm_min_ERR
99 Configuration error
100 Error analysis is in progress…
101 ComfoNet Error
102 The number of CO2 sensors has decreased – one or more sensors are no longer detected
103 More than 8 sensors detected in a zone
104 CO₂ Sensor C error
# Firmware 1.4.0
70 ComfoHood was present, but is no longer detected (HOOD_CONNECT ERROR)
71 ComfoCool was present, but is no longer detected (CCOOL_CONNECT ERROR)
72 ComfoFond was present, but is no longer detected (GROUND_HEAT_CONNECT ERROR)
73 The filters of the Ventilation Unit must be replaced now
74 It is necessary to replace or clean the external filter
75 Order new filters now, because the remaining filter life time is limited
76 Service mode is active (SERVICE MODE)
77 Preheater has no communication with the ComfoAir unit (PREHEAT ERROR , 1081)
78 ComfoHood temperature error (HOOD_TEMP ERROR)
79 Postheater temperature error (POSTHEAT_TEMP ERROR)
80 Outdoor temperature of ComfoFond error (GROUND_HEAT_TEMP ERROR)
81 Bypass is in manual mode
82 ComfoCool is overheating
83 ComfoCool compressor error (CCOOL_COMPRESSOR ERROR)
84 ComfoCool room temperature sensor error (CCOOL_TEMP ERROR)
85 ComfoCool condensor temperature sensor error (CCOOL_TEMP ERROR)
86 ComfoCool supply air temperature sensor error (CCOOL_TEMP ERROR)

Example list of commonly-used commands

See the comfoconnect.py file for more commands and how they are constructed.

Command Description
84 15 01 01 00000000 01000000 00 Switch to fan speed away
84 15 01 01 00000000 01000000 01 Switch to fan speed 1
84 15 01 01 00000000 01000000 02 Switch to fan speed 2
84 15 01 01 00000000 01000000 03 Switch to fan speed 3
84 15 01 06 00000000 58020000 03 Boost mode: start for 10m (= 600 seconds = 0x0258)
85 15 01 06 Boost mode: end
85 15 08 01 Switch to auto mode
84 15 08 01 00000000 01000000 01 Switch to manual mode
84 15 06 01 00000000 100e0000 01 Set ventilation mode: supply only for 1 hour
85 15 06 01 Set ventilation mode: balance mode
84 15 03 01 00000000 ffffffff 00 Set temperature profile: normal
84 15 03 01 00000000 ffffffff 01 Set temperature profile: cool
84 15 03 01 00000000 ffffffff 02 Set temperature profile: warm
84 15 02 01 00000000 100e0000 01 Set bypass: activated for 1 hour
84 15 02 01 00000000 100e0000 02 Set bypass: deactivated for 1 hour
85 15 02 01 Set bypass: auto
03 1d 01 04 00 Set sensor ventilation: temperature passive: off
03 1d 01 04 01 Set sensor ventilation: temperature passive: auto only
03 1d 01 04 02 Set sensor ventilation: temperature passive: on
03 1d 01 06 00 Set sensor ventilation: humidity comfort: off
03 1d 01 06 01 Set sensor ventilation: humidity comfort: auto only
03 1d 01 06 02 Set sensor ventilation: humidity comfort: on
03 1d 01 07 00 Set sensor ventilation: humidity protection: off
03 1d 01 07 01 Set sensor ventilation: humidity protection: auto
03 1d 01 07 02 Set sensor ventilation: humidity protection: on