Subject: [PATCH] Adjust LargeScaleWaterToWater_OneRoomRadiator.mo example to
trigger cooling operation and change sizing for better cooling operation
---
.../LargeScaleWaterToWater_OneRoomRadiator.mo | 49 ++++++++++---------
1 file changed, 26 insertions(+), 23 deletions(-)
diff --git a/IBPSA/Fluid/HeatPumps/ModularReversible/Examples/LargeScaleWaterToWater_OneRoomRadiator.mo b/IBPSA/Fluid/HeatPumps/ModularReversible/Examples/LargeScaleWaterToWater_OneRoomRadiator.mo
index ef7172d75f..f914d3e5f3 100644
--- a/IBPSA/Fluid/HeatPumps/ModularReversible/Examples/LargeScaleWaterToWater_OneRoomRadiator.mo
+++ b/IBPSA/Fluid/HeatPumps/ModularReversible/Examples/LargeScaleWaterToWater_OneRoomRadiator.mo
@@ -11,15 +11,15 @@ model LargeScaleWaterToWater_OneRoomRadiator
Q_flow_nominal=200000,
sin(nPorts=1),
booToReaPumEva(realTrue=heaPum.mEva_flow_nominal),
- redeclare IBPSA.Fluid.Movers.FlowControlled_m_flow pumHeaPumSou(
- redeclare IBPSA.Fluid.Movers.Data.Pumps.Wilo.VeroLine80slash115dash2comma2slash2 per),
- redeclare IBPSA.Fluid.Movers.FlowControlled_m_flow pumHeaPum(
- redeclare IBPSA.Fluid.Movers.Data.Pumps.Wilo.VeroLine80slash115dash2comma2slash2 per));
+ pumHeaPumSou(dp_nominal=150000),
+ pumHeaPum(dp_nominal=150000),
+ sou(use_T_in=true));
IBPSA.Fluid.HeatPumps.ModularReversible.LargeScaleWaterToWater heaPum(
allowDifferentDeviceIdentifiers=true,
QHea_flow_nominal=Q_flow_nominal,
use_intSafCtr=true,
+ QCoo_flow_nominal=-Q_flow_nominal/2,
TConHea_nominal=TRadSup_nominal,
dpCon_nominal(displayUnit="Pa"),
TEvaHea_nominal=sou.T,
@@ -28,7 +28,7 @@ model LargeScaleWaterToWater_OneRoomRadiator
redeclare IBPSA.Fluid.HeatPumps.ModularReversible.Controls.Safety.Data.Wuellhorst2021
safCtrPar,
TConCoo_nominal=oneRooRadHeaPumCtr.TRadMinSup,
- TEvaCoo_nominal=sou.T + 10,
+ TEvaCoo_nominal=sou.T + 30,
redeclare
IBPSA.Fluid.HeatPumps.ModularReversible.Data.TableData2D.EN14511.WAMAK_WaterToWater_220kW
datTabHea,
@@ -37,6 +37,16 @@ model LargeScaleWaterToWater_OneRoomRadiator
datTabCoo)
"Large scale water to water heat pump"
annotation (Placement(transformation(extent={{20,-160},{0,-140}})));
+ Modelica.Blocks.Sources.Pulse TAirSouSte(
+ amplitude=20,
+ width=10,
+ period=86400,
+ offset=283.15,
+ startTime=86400/2) if witCoo "Air source temperature step for cooling phase"
+ annotation (Placement(transformation(
+ extent={{-10,-10},{10,10}},
+ rotation=0,
+ origin={-150,-200})));
equation
connect(heaPum.port_b2, sin.ports[1]) annotation (Line(points={{20,-156},{38,
-156},{38,-200},{60,-200}}, color={0,127,255}));
@@ -47,11 +57,13 @@ equation
connect(heaPum.port_a1, temRet.port_b) annotation (Line(points={{20,-144},{60,
-144},{60,-30}}, color={0,127,255}));
connect(oneRooRadHeaPumCtr.ySet, heaPum.ySet) annotation (Line(
- points={{-139.167,-66.6667},{26,-66.6667},{26,-148},{21.2,-148}},
+ points={{-139.167,-66.6667},{26,-66.6667},{26,-148.1},{21.1,-148.1}},
color={
0,0,127}));
connect(oneRooRadHeaPumCtr.hea, heaPum.hea) annotation (Line(points={{
- -139.167,-75},{32,-75},{32,-151.9},{21.1,-151.9}}, color={255,0,255}));
+ -139.167,-75},{32,-75},{32,-152.1},{21.1,-152.1}}, color={255,0,255}));
+ connect(TAirSouSte.y, sou.T_in) annotation (Line(points={{-139,-200},{-92,-200},
+ {-92,-196},{-82,-196}}, color={0,0,127}));
annotation (
__Dymola_Commands(file=
"modelica://IBPSA/Resources/Scripts/Dymola/Fluid/HeatPumps/ModularReversible/Examples/LargeScaleWaterToWater_OneRoomRadiator.mos"
@@ -76,23 +88,14 @@ equation
Furthermore, this example demonstrates the warnings which
- are raised if the table data boundary conditions
- (e.g. mEva_flow_nominal
) deviates from
- the parameter in use.
+ are raised if two devices are combined with different sizes, leading
+ to different scaling factors for heating and cooling operation.
+ If the default QCoo_flow_nominal
is used (leading to
+ the same scaling factors), the mass flow rates will differ.
+ Setting the parameter allowDifferentDeviceIdentifiers
to false,
+ an additional warning is raised, indicating that the table data for cooling and
+ heating operation do not originate from the same real device.
-
- To fix this issue, the user has to either
-
-
--
-Check the assumption of using a different mass flow rate, or
-
--
-adjust the mass flow rates in the hydraulic system.
-If the deviation is too big, the system would also not
-work in reality.
-
-
Please check the documentation of