diff --git a/IBPSA/Fluid/Actuators/BaseClasses/ActuatorSignal.mo b/IBPSA/Fluid/Actuators/BaseClasses/ActuatorSignal.mo index b2309c0a4e..8f2321fc46 100644 --- a/IBPSA/Fluid/Actuators/BaseClasses/ActuatorSignal.mo +++ b/IBPSA/Fluid/Actuators/BaseClasses/ActuatorSignal.mo @@ -7,7 +7,7 @@ model ActuatorSignal annotation(Dialog(tab="Dynamics", group="Actuator position")); parameter Modelica.Units.SI.Time strokeTime=120 - "Time needed to open or close valve" + "Time needed to fully open or close actuator" annotation (Dialog( tab="Dynamics", group="Actuator position", @@ -122,7 +122,8 @@ for a description of the filter.
  • August 26, 2024, by Michael Wetter:
    Implemented linear actuator travel dynamics.
    -This is for Buildings, #3965. +This is for Buildings, #3965 and +for IBPSA, #1926.
  • June 10, 2021, by Michael Wetter: