Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Allow fan coil distribution #322

Open
shorowit opened this issue Jun 24, 2022 · 3 comments
Open

Allow fan coil distribution #322

shorowit opened this issue Jun 24, 2022 · 3 comments

Comments

@shorowit
Copy link
Contributor

shorowit commented Jun 24, 2022

HPXML currently supports distribution systems of type AirDistribution, HydronicDistribution, and Other.

Fan coils have aspects of both air and hydronic distribution. They have hot (or chilled) water running through them, blow air via a fan, and can be ducted. They can also be used to provide mechanical ventilation to the space in addition to space conditioning (similar to CFIS).

I propose that we add a new FanCoilDistribution type that would include most of the child elements across the AirDistribution and HydronicDistribution elements. This new distribution system type could also be referenced from a VentilationFan/AttachedToHVACDistributionSystem for ventilation.

@shorowit

This comment was marked as outdated.

@shorowit
Copy link
Contributor Author

Cooling options: chilled water or direct expansion coil
Heating options: hot water, steam, or electric coil

@nmerket
Copy link
Contributor

nmerket commented Jul 19, 2022

@shorowit shorowit modified the milestones: v4.0, v4.1 Sep 19, 2023
@shorowit shorowit modified the milestones: v4.1, v5.0 Sep 23, 2024