MQTT
Bernhard Kirchen edited this page Jul 28, 2023
·
15 revisions
Only OpenDTU-OnBattery specific topics are documented here. Refer to MQTT_Topics.md for documentation of topics that are part of the upstream OpenDTU project and therefore are also part of OpenDTU-OnBattery.
Topic | R / W | Description | Value / Unit |
---|---|---|---|
victron/[serial]/PID | R | Product description | text |
victron/[serial]/SER | R | Serial number | text |
victron/[serial]/FW | R | Firmware number | int |
victron/[serial]/LOAD | R | Load output state | ON / OFF |
victron/[serial]/CS | R | State of operation | text e. g. "Bulk" |
victron/[serial]/ERR | R | Error code | text e. g. "No error" |
victron/[serial]/OR | R | Off reasen | text e. g. "Not off" |
victron/[serial]/MPPT | R | Tracker operation mode | text e. g. "MPP Tracker active" |
victron/[serial]/HSDS | R | Day sequence number (0...364) | int in days |
Topic | R / W | Description | Value / Unit |
---|---|---|---|
victron/[serial]/V | R | Voltage | Volt (V) |
victron/[serial]/I | R | Current | Ampere (A) |
Topic | R / W | Description | Value / Unit |
---|---|---|---|
victron/[serial]/VPV | R | Voltage | Volt (V) |
victron/[serial]/PPV | R | Power | Watt (W) |
victron/[serial]/H19 | R | Yield total (user resettable counter) | Kilo watt hours (kWh) |
victron/[serial]/H20 | R | Yield today | Kilo watt hours (kWh) |
victron/[serial]/H21 | R | Maximum power today | Watt (W) |
victron/[serial]/H22 | R | Yield yesterday | Kilo watt hours (kWh) |
victron/[serial]/H23 | R | Maximum power yesterday | Watt (W) |
Topic | R / W | Description | Value / Unit |
---|---|---|---|
battery/settings/chargeVoltage | R | Voltage | Volt (V) |
battery/settings/chargeCurrentLimitation | R | BMS requested max. charge current | Ampere (A) |
battery/settings/dischargeCurrentLimitation | R | BMS requested max. discharge current | Ampere (A) |
battery/stateOfCharge | R | State of Health | % |
battery/stateOfHealth | R | State of Charge | % |
battery/dataAge | R | How old the data is | Seconds |
battery/voltage | R | Actual voltage | Volt (V) |
battery/current | R | Actual current | Ampere (A) |
battery/temperature" | R | Actual temperature | °C |
battery/alarm/overCurrentDischarge | R | Alarm: High discharge current | 0 / 1 |
battery/alarm/underTemperature | R | Alarm: Low temperature | 0 / 1 |
battery/alarm/overTemperature | R | Alarm: High temperature | 0 / 1 |
battery/alarm/underVoltage | R | Alarm: Low voltage | 0 / 1 |
battery/alarm/overVoltage | R | Alarm: High voltage | 0 / 1 |
battery/alarm/bmsInternal | R | Alarm: BMS internal | 0 / 1 |
battery/alarm/overCurrentCharge | R | ||
battery/warning/highCurrentDischarge | R | Warning: High discharge current | 0 / 1 |
battery/warning/lowTemperature | R | Warning: Low temperature | 0 / 1 |
battery/warning/highTemperature | R | Warning: High temperature | 0 / 1 |
battery/warning/lowVoltage | R | Warning: Low voltage | 0 / 1 |
battery/warning/highVoltage | R | Warning: High voltage | 0 / 1 |
battery/warning/bmsInternal | R | Warning: BMS internal | 0 / 1 |
battery/manufacturer | R | Manufacturer | String |
battery/charging/chargeEnabled | R | Charge enabled flag | 0 / 1 |
battery/charging/dischargeEnabled | R | Discharge enabled flag | 0 / 1 |
battery/charging/chargeImmediately | R | Charge immediately flag | 0 / 1 |
Topic | R / W | Description | Value / Unit |
---|---|---|---|
huawei/cmd/limit_online_voltage | W | Online voltage (i.e. CAN bus connected) | Volt (V) |
huawei/cmd/limit_online_current | W | Online current (i.e. CAN bus connected) | Ampere (A) |
huawei/cmd/limit_offline_voltage | W | Offline voltage (i.e. CAN bus not connected) | Volt (V) |
huawei/cmd/limit_offline_current | W | Offline current (i.e. CAN bus not connected) | Ampere (A) |
huawei/cmd/mode | W | Controls GPIO output pin to switch slot detect | 0 (off) / 1 (on) / 2 (set automatically depending on online_current value) / 3 (set automatically based on Power Meter reading ) |
huawei/data_age | R | How old the data is | Seconds |
huawei/input_voltage | R | Input voltage | Volt (V) |
huawei/input_current | R | Input current | Ampere (A) |
huawei/input_power | R | Input power | Watt (W) |
huawei/output_voltage | R | Output voltage | Volt (V) |
huawei/output_current | R | Output current | Ampere (A) |
huawei/max_output_current | R | Maximum output current (set using the online limit) | Ampere (A) |
huawei/output_power | R | Output power | Watt (W) |
huawei/input_temp | R | Input air temperature | °C |
huawei/output_temp | R | Output air temperature | °C |
huawei/efficiency | R | Efficiency | Percentage |
Topic | R / W | Description | Value |
---|---|---|---|
powerlimiter/cmd/mode | W | Power Limiter operation mode | see below |
powerlimiter/status/mode | R | Get Power Limiter operation mode | see below |
Setting any of these modes through MQTT has no effect if the Power Limiter is disabled by configuration in the web application. The Power Limiter will stay off in that case.
Three modes are implemented:
- 0 - Normal operation: The Power Limiter works as configured through the web application.
- 1 - Fully disable: The inverter is shut down and the Power Limiter stops operating, as if it was disabled in the web application.
- 2 - Unconditional Solar Passthrough: The power limit is set such that all solar power (adjusted for efficiency) is fed into the home. This is done irrespective of grid consumption and without consuming energy from the battery, which is the key difference to the regular Power Limiter Solar Passthrouh feature. Essentially, the inverter mimics the behavior of a traditional, non-smart inverter. This can be particularly useful in scenarios where solar power is better stored elsewhere, such as in an electric car.
- Home
- FAQ
- First-Time Installation
- Device Profiles (Pin Config)
- Upgrade from OpenDTU
- Getting Help
- Hilfe erhalten
- Builds & Examples
- ESP32 Versions and Memory
- Victron MPPT solar charger
- VE.Direct
- Victron Smartshunt
- Victron Smart Battery Sense
- Warning on Victron MPPT 100/20
- Pylontech battery
- Pytes battery
- Huawei AC PSU
- SBS Unipower Battery
- Jikong JK BMS
- HOYMILES
- Einschaltstrombegrenzung für Balkonkraftwerke - Inrush current limiter
- Live View
- Farbe des Wechselrichterfensters
- Power Meter
- Dynamic Power Limiter
- Dynamic Power Limiter ‐ (Full) Solar‐Passthrough
- Dynamic Power Limiter Limitations
- DC Voltage ‐ Load correction factor
- Battery
- Battery-Tipps
- 24V Battery issues with Hoymiles
- Home Assistant
- Grafana Dashboard
- XXL Balkonkraftwerk 1500 Watt und mehr! Worauf Ihr achten solltet!
- Wie gefährlich kann ein Balkonkraftwerk werden (FI‐Schutzschalter)
- Hardware Purchase Tipp
- Fan speed controller ‐ add temperature sensing to any fan
- Cable length(s) between battery and inverter
- Kabellänge(n) zwischen Batterie und Wechselrichter
- Diodes ‐ Bypass vs. Blocking Diodes
- Impact of high start-currents to the inverter
- Making Cables for your HOYMILES‐CAUTION