I am unable to produce this graph. The video url is also not working. Will you please help ? I'm willing to work on the issue. |
Hi. I've checked the video link, it seems to be working. The set-up is as such:
Feel free to contact me if you need more assistance |
@geekyjoyce72 can you please check whether this issue still exist with latest changes. Thanks |
@CloudyPadmal able to check this for the next version hardware? |
Low pass filter capacitor will be replaced by C0603X508D4HACTU 0.5 pF capacitor increasing the cutoff frequency to 1.99~1.33 MHz considering +/-0.1 pF tolerance. |
Actual Behaviour
Waveforms above 50 kHz appear distorted.
Expected Behaviour
Waveforms should appear as they are, as per specifications (there's no specification listed on the maximum frequency of the oscilloscope channels)
Steps to reproduce it
LogCat for the issue
Not applicable
Screenshots of the issue
Refer to attached video @ https://gofile.io/?c=FZKiRT
PSLab App Screenshot:
Op-amp output:
Would you like to work on the issue?
Am willing to help.