@RonRahaman How to convert |
You can generate a .nek5000 file using the nrsvis or visnek scripts in
This would produce The |
Thanks @RonRahaman But Why the temperature range starts from ~143 K instead of ~ 523 K? |
Is this from |
This is from |
The "temperature" field in
A pretty fundamental implementation detail in nekRS prevents us from directly using a passive scalar for heat source. I can elaborate if you like. |
Ah, I see! Really confusing Thanks @RonRahaman :) |
No problem! I was really hoping nekRS would let us use a passive scalar field for heat source. However, for a conjugate heat transfer problem in nekRS, the additional (non-temperature) passive scalars fields are defined on the velocity mesh, not the temperature mesh. So that's no good for us. :( |
It would be useful to read/write the localq values to/from a Nek fld file. That would let us to do several useful things, including: