Separations archetype: metastable nuclides not going to leftover stream #575
Comments
I can work around this by creating a product stream for these metastable nuclides, but I found that some of these nuclides disappear when transferring them out of the separations facility to a sink facility. |
Thanks for reporting this @danielwojtaszek . Can you share the input file snippet that describes how you define you separations facility and its separation efficiencies? |
Hi Paul (@gonuke). Here's the prototype definition I was using when I discovered the issue.
|
I've noticed that some metastable nuclides (such as 471080001 and 330820001) in the feed inventory of the separations archetype that are not placed in any product streams end up not going to the leftover stream, and thus disappear from the system altogether. Note that the decay control parameter of the simulation is set to never.
The disappearance of 471080001 (aka Ag-108m) is particularly odd since its half-life is > 400 years.
The text was updated successfully, but these errors were encountered: