EmonHub Configuration

emonHub is configured with emonhub.conf config file. On the emonPi / emonBase this file is located in the R/W data partition /home/pi/data/emonhub.conf. If the Emoncms Config module is installed (as in the case of the emonPi / emonBase using pre-buit SD card image) the config file can be edited direct from the EmonHub tab in local Emoncms, see User Guide

Emonhub.conf has 3 sections:

1. hub

Hub is a section for emonhub global settings such as the loglevel.

2. interfacers

Interfacers holds the configuration for the different interfacers that emonhub supports such as the EmonHubJeeInterfacer for reading and writing to the RFM69Pi adapter board or emonPi board via serial, or the EmonHubMqttInterfacer which can be used to publish the data received from EmonHubJeeInterfacer to MQTT topics. For more interfacer examples see conf/interfacer_examples

Channels

Each interfacer can listen on a subchannel or publish on a pubchannel. Some interfacers can do both.

For Example:

Ther Serial Interfacer listens on the serial port then publishes that data for onward transmission - it has a pubchannel defined.

The MQTT interfacer listens for data which it then sends out via MQTT, it therefore defines a subchannel that it will listen on for data to send via MQTT.

For data to be passed, the name of the 2 channels must match.

Each interfacer can have multiple channels defined and multiple interfacers can listen to the same channel. e.g. data published by the Serial Interfacer can be listened (subscribed) for by the MQTT and the HTTP interfacer.

3. nodes

Nodes holds the decoder configuration for rfm12/69 node data which are sent as binary structures.

#######################################################################
        #######################      emonhub.conf     #########################
        #######################################################################
        ### emonHub configuration file, for info see documentation:
        ### https://github.com/openenergymonitor/emonhub/blob/emon-pi/conf/emonhub.conf
        #######################################################################
        #######################    emonHub  settings    #######################
        #######################################################################
        [hub]
        ### loglevel must be one of DEBUG, INFO, WARNING, ERROR, and CRITICAL
        loglevel = DEBUG

        #######################################################################
        #######################       Interfacers       #######################
        #######################################################################
        [interfacers]

        #######################################################################
        #######################          Nodes          #######################
        #######################################################################
        [nodes]

View full latest default emonHub.conf


1. 'hub' Configuration

Hub is a section for emonhub global settings such as the loglevel.

The hub configuration should be self explanatory. Emonhub log can be viewed in the Setup > EmonHub section of local Emoncms on an emonPi / emonBase. Default settings are:

### loglevel must be one of DEBUG, INFO, WARNING, ERROR, and CRITICAL
loglevel = DEBUG
### Uncomment this to also send to syslog
# use_syslog = yes

2. 'interfacers' Configuration

Interfacers holds the configuration for the different interfacers that emonhub supports such as the EmonHubJeeInterfacer for reading and writing to the RFM69Pi adapter board or emonPi board via serial, or the EmonHubMqttInterfacer which can be used to publish the data received from EmonHubJeeInterfacer to MQTT topics.

Each interfacer has a unique name between the first set of double brackets [[xxx]]

The Type corresponds to the interfacer file name as found in src/interfacers/ directory.

[[[init_settings]]] are settings used by the interfacer on setup. These are usually defined in the header of the interfacer file.

[[[runtime_settings]]] are other settings for the interfacer. The first setting in this group must be either pubchannels or subchannels and must end with a comma. There must be a blank line. The remaining options are optional and if not specified will fall back to the interfacer defaults.

a.) [[RFM2Pi]]

The [[RFM2Pi]] interfacer section contains the settings to read from RFM69Pi / emonPi boards via GPIO internal serial port /dev/ttyAMA0. The default serial baud on all emonPi and RFM69Pi is 38400. Older RFM12Pi boards using 9600 baud.

The frequency and network group must match the hardware and other nodes on the network.

The calibration config is used to set the calibration of the emonPi when using USA AC-AC adapters 110V. Set calibration = 110V when using USA AC-AC adapter.

[[RFM2Pi]]
    Type = EmonHubJeeInterfacer
    [[[init_settings]]]
        com_port = /dev/ttyAMA0
        com_baud = 38400                        # 9600 for old RFM12Pi
    [[[runtimesettings]]]
        pubchannels = ToEmonCMS,
        subchannels = ToRFM12,

        group = 210
        frequency = 433
        baseid = 5                              # emonPi / emonBase nodeID
        quiet = true                            # Report incomplete RF packets (not implemented on emonPi)
        calibration = 230V                      # (UK/EU: 230V, US: 110V)
        # interval =  0                         # Interval to transmit time to emonGLCD (seconds)

b.) [[MQTT]]

Emonhub supports publishing to MQTT topics through the EmonHubMqttInterfacer, defined in the interfacers section of emonhub.conf.

There are two formats that can be used for publishing node data to MQTT:

1. Node only format

(default base topic is emonhub)

    topic: basetopic/rx/10/values
    payload: 100,200,300

The 'node only format' is used with the emoncms Nodes Module (now deprecated on Emoncms V9+) and the emonPiLCD python service.

2. Node variable format

(default base topic is emon)

    topic: basetopic/emontx/power1
    payload: 100

The 'Node variable format' is the current default format from Emoncms V9. It's a more generic MQTT publishing format that can more easily be used by applications such as NodeRED and OpenHab. This format can also be used with the emoncms phpmqtt_input.php script in conjunction with the emoncms inputs module. See User Guide > Technical MQTT.

3. JSON format

Defaults
'node_format_enable': 1,
'node_format_basetopic': 'emonhub/',
'nodevar_format_enable': 0,
'nodevar_format_basetopic': "nodes/",
'node_JSON_enable': 0,
'node_JSON_basetopic': "emon/"

Emoncms default base topic that it listens for is emon/.

topic: basetopic/<noeid>
payload: {"key1":value1, "key2":value2, .... "time":<timestamp>, "rssi":<rssi>}

This forat exports the data as a single JSOn string with key:value pairs. The timestamp is automatically added and used for the input time to emoncms. The RSSI is added if available (RF in use).

Default [MQTT] config

Note - the trailing / is required on the topic definition.

[[MQTT]]

    Type = EmonHubMqttInterfacer
    [[[init_settings]]]
        mqtt_host = 127.0.0.1
        mqtt_port = 1883
        mqtt_user = emonpi
        mqtt_passwd = emonpimqtt2016

    [[[runtimesettings]]]
        # pubchannels = ToRFM12,
        subchannels = ToEmonCMS,

        # emonhub/rx/10/values format
        # Use with emoncms Nodes module
        node_format_enable = 0
        node_format_basetopic = emonhub/

        # emon/emontx/power1 format - use with Emoncms MQTT input
        # http://github.com/emoncms/emoncms/blob/master/docs/RaspberryPi/MQTT.md
        nodevar_format_enable = 1
        nodevar_format_basetopic = emon/

        # Single JSON payload published  - use with Emoncms MQTT
        node_JSON_enable = 0
        node_JSON_basetopic = emon/

To enable one of the formats set the enable flag to 1. More than one format can be used simultaneously.

c.) [[emoncmsorg]]

The EmonHubEmoncmsHTTPInterfacer configuration that is used for sending data to emoncms.org (or any instance of emoncms). If you wish to use emoncms.org the only change to make here is to replace the blank apikey with your write apikey from emoncms.org found on the user account page. See Setup Guide > Setup > Remote logging.

    [[emoncmsorg]]
        Type = EmonHubEmoncmsHTTPInterfacer
        [[[init_settings]]]
        [[[runtimesettings]]]
            pubchannels = ToRFM12,
            subchannels = ToEmonCMS,
            url = https://emoncms.org
            apikey = xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
            senddata = 1
            sendstatus = 1

sendstatus - It is possible to the EmonHubEmoncmsHTTPInterfacer to send a 'ping' to the destination emoncms that can be picked up by the myip module which will then list the source IP address. This can be useful for remote login to a home emonpi if port forwarding is enabled on your router.

senddata - If you only want to send the ping request, and no data, to emoncms.org set this to 0

You can create more than one of these sections to send data to multiple emoncms instances. For example, if you wanted to send to an emoncms running at emoncms.example.com (or on a local LAN) you would add the following underneath the emoncmsorg section described above:

    [[emoncmsexample]]
        Type = EmonHubEmoncmsHTTPInterfacer
        [[[init_settings]]]
        [[[runtimesettings]]]
            pubchannels = ToRFM12,
            subchannels = ToEmonCMS,
            url = https://emoncms.example.com
            apikey = xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
            senddata = 1
            sendstatus = 1

This time, the API key will be the API key from your account at emoncms.example.com.

Interfacers Extended

In addition to the above core interfacers used as part of the core OpenEnergyMonitor configuration, EmonHub supports a wide variety of interfacers for reading data from different hardware sources, these interfacers have been documented separately, follow the links for more information:


3. 'nodes' Configuration

The 2nd part of the emonhub.conf configuration concerns decoding of RFM12 and RFM69 nodes. The data in encoded before transmission and the received data must therefore be 'decoded' i.e. converted from a raw datacode to recgonisable values.

Here's an example of what this section looks like from the default emonpi emonhub.conf. The rest of this readme explains what each line means and how to write your own node decoders or adapt existing decoders for new requirements.


    #######################################################################
    #######################          Nodes          #######################
    #######################################################################

    [nodes]

    ### List of nodes by node ID
    ### 'datacode' is default for node and 'datacodes' are per value data codes.
    ### if both are present 'datacode' is ignored in favour of 'datacodes'.
    ### e.g. node 99 would expect 1 long and 4 ints, unless the "datacodes" line
    ### was removed, then "datacode" would make it expect any number of longs.
    ### Likewise per value "scales" will override default node "scale"

    [[5]]
    nodename = emonPi
    firmware = emonPi_RFM69CW_RF12Demo_DiscreteSampling.ino
    hardware = emonpi
    [[[rx]]]
        names = power1,power2,power1_plus_power2,Vrms,T1,T2,T3,T4,T5,T6,pulseCount
        datacodes = h, h, h, h, h, h, h, h, h, h, L
        scales = 1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
        units = W,W,W,V,C,C,C,C,C,C,p

NodeID

[[10]]

A numeric NodeID. This identifies the node to emonHub. Every node within your system MUST have a unique ID. There may be only one definition for each NodeId. The NodeID is programmed into the node firmware, either in the sketch and/or by switches.

nodename

nodename =

A text string, for your benefit in identifying each node. This field is optional.

MQTT: The nodename can be used with the MQTT interfacer to send topics of the form nodes/nodename/variablename.

firmware

firmware =

A text string specifying the sketch running on the node. (At present, this is for information only. At some future time, it might be used to auto-configure emonHub and/or the sketch.) This field is optional.

hardware

hardware =

Indicates the host environment for human reference. This field is optional.

rx

[[[rx]]]

This must be "rx" and specifies that the next section is for the config of the sensor values received from a node. Its also possible to define a "tx" section for variables to be sent to the node such as control state's.

tx

[[[tx]]]

It's possible to transmitt data to other nodes via RFM e.g. the following config

    [[[tx]]]
        names=nodeid,hour,minute,second,utilityW,solarW,utilityKwh,solarKwh
        datacodes =b,b,b,h,h,H,H
        units = h,min,sec,W,W,kwh,kwh

The following data published to MQTT

emonhub/tx/20/values/14,38,34,700,138,2700,829

Will result in the follwing data being transmitted via RF in JeeLib packet formatt:

14,38,34,700,138,2700,829

To decode the RFM data use the following struct in the receiver node, emonGLCD in this example:

typedef struct {
  byte nodeId ;
  byte hour, min, sec ;
  int utilityW, solarW, utilityKwh, solarKwh;
} PayloadTX;

See PR #68 and emonGLCD PR #12 for MQTT data transmission.

Datacodes

An un-configured Emonhub will by default assume that RFM12 or RFM69 data packets received are a series of integers, each 2 bytes long (when using the Jee interfacer). The radio packet format is quite minimal and non-descriptive and so emonhub doesn't know how to decode the packets from the received data if the packet structure is any different.

Earlier OpenEnergyMonitor nodes always sent a series of integers and so no decoder configuration was needed, more recent revisions now include the sending of pulse counts or watt hours which would overrun the maximum value that can be sent as an integer. The latest EmonPi, EmonTx3 and EmonTH firmware's all send pulse count as long datatypes at the end of their packets, taking up 4 bytes.

Its possible to decode any radio packet that is packed as a binary structure with Emonhub. For example if we look at the relevant part of the node decoder for the emontx v3 we can see 11 integers (h) and one unsigned long at the end (L)

[[8]]
    [[[rx]]]
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L

The node decoder could be left like this if we only wanted to decode the packet structure correctly. Alternatively, if the packet structure is a series of integers its possible to write:

[[1]]
    [[[rx]]]
        datacode = h

Notice that the name is datacode rather than datacodes with an s. There are 13 different datatypes that can be decoded:

    b: byte, 1 byte
    h: short integer, 2 bytes
    i: integer, 4 bytes
    l: long, 4 bytes
    q: long long, 8 bytes
    f: float, 4 bytes
    d: double, 8 bytes
    B: unsigned byte, 1 byte
    H: unsigned short integer, 2 bytes
    I: unsigned integer, 4 bytes
    L: unsigned long, 4 bytes
    Q: unsigned long long, 8 bytes
    c: char, 1 byte

datacode = 0 is a valid datacode. It is best remembered by thinking of it as either "0 = False" (no decoding) or "Zero decoding required"; in code it is a logical test as to whether to continue, or bypass, decoding the value(s).

Note: A datacode can also be set in the runtimesettings of any interfacer; e.g. if you added datacode = h to the serial or socket interfacers, that would mean if the datacode(s) line is omitted from the nodes section, it will default to “h” rather than the hardcoded default of “0”.

Names

It's possible to specify sensor value names to help with identification. The emoncms nodes module can also load these names for its node list. Another possibility not yet implemented, is to use these names to publish sensor values to MQTT topics of the form nodes/emontx/power1.

[[8]]
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L

Scales

In order to keep radio packet length small, a sensor value measured as a float on an emontx or emonth (e.g. temperature) is first multiplied by 10 or 100, then sent as a 2-byte integer in the radio packet, then scaled back to the original value on receipt in emonhub. This saves 2 bytes per sensor value and provides a convenient way of providing 1 or 2 decimal place resolution.

The scales to be applied can be specified for each sensor value as in this example for the emontx:

[[8]]
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L
        scales = 1,1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1

In this example, the RMS Voltage is multiplied by 0.01, and temperature values by 0.1. Which means the RMS voltage was multiplied by 100 and the temperature value(s) by 10, on the emontx.

or a single scale can be applied (note scale instead of scales with an s)

[[8]]
    [[[rx]]]
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L
        scale = 1

The default scale value is 1, so where no scaling is needed, this line can be left out of the configuration.

The latest version of the emon-pi variant of emonhub does not require the number of scales to match the number of variables, it will scale according to the scales available or scale by 1 if scales are not available.

Units

A comma-separated list of engineering units to describe the data. Common units are W, kW, V, A, C, %. These are only to help with identification. The are currently used in the emoncms nodes module UI.

[[8]]
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L
        scales = 1,1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
        units =W,W,W,W,V,C,C,C,C,C,C,p

Standard node decoders

The following lists the standard node decoders for recent versions of the EmonPi, EmonTx v3, EmonTH and EmonTxShield. These are currently included in emonhub.conf and provide automatic decoding of node data.

If you upload firmware to any of these nodes, and wish to have the data decoded with names, units, and scaled correctly, these are the decoders for the standard firmware. The node decoders are also included at the top of each firmware file for reference.

EmonPi

Firmware location

Copied here for reference:

[[5]]
    nodename = emonPi
    firmware = emonPi_RFM69CW_RF12Demo_DiscreteSampling.ino
    hardware = emonpi
    [[[rx]]]
        names = power1,power2,power1_plus_power2,Vrms,T1,T2,T3,T4,T5,T6,pulseCount
        datacodes = h, h, h, h, h, h, h, h, h, h, L
        scales = 1,1,1,0.01,0.1,0.1,0.1,0.1,0.1,0.1,1
        units = W,W,W,V,C,C,C,C,C,C,p

EmonTx v3.4 DS Firmware V2.3+

Firmware location

Node ID when DIP switch1 is off = 8, node ID when DIP switch1 is on is 7

Copied here for reference:

[[8]]
    nodename = emonTx_3
    firmware =V2_3_emonTxV3_4_DiscreteSampling
    hardware = emonTx_(NodeID_DIP_Switch1:OFF)
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
        datacodes = h,h,h,h,h,h,h,h,h,h,h,L
        scales = 1,1,1,1,0.01,0.1,0.1, 0.1,0.1,0.1,0.1,1
        units =W,W,W,W,V,C,C,C,C,C,C,p

EmonTx v3.4 DS Firmware 1.6+

EmonTx v3 (emonTxV3_4_DiscreteSampling.ino, v1.6+) Firmware Location

Can be on either nodeid 10 or 9

[[10]]
    nodename = emonTx_1
    firmware =V1_6_emonTxV3_4_DiscreteSampling
    hardware = emonTx_(NodeID_DIP_Switch1:OFF)
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp1, temp2, temp3, temp4, temp5, temp6, pulse
        datacode = h
        scales = 1,1,1,1,0.01,0.1,0.1, 0.1,0.1,0.1,0.1,1 #Firmware V1.6
        units =W,W,W,W,V,C,C,C,C,C,C,p

EmonTx v3, emonTxV3_4_DiscreteSampling.ino, < V1.4

[[10]]
    nodename = emonTx_1
    firmware =V1_6_emonTxV3_4_DiscreteSampling
    hardware = emonTx_(NodeID_DIP_Switch1:OFF)
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms, temp
        datacode = h
        scales = 1,1,1,1,0.01,0.1
        units =W,W,W,W,V,C

EmonTH V2

EmonTH V2 Firmware location

Standard nodeid's: 23, 24, 25 & 26 depending on DIP switch positions:

[[23]]
    nodename = emonTH_5
    firmware = V2.x_emonTH_DHT22_DS18B20_RFM69CW_Pulse
    hardware = emonTH_(Node_ID_Switch_DIP1:OFF_DIP2:OFF)
    [[[rx]]]
        names = temperature, external temperature, humidity, battery, pulseCount
        datacodes = h,h,h,h,L
        scales = 0.1,0.1,0.1,0.1,1
        units = C,C,%,V,p

EmonTH V1, emonTH_DHT22_DS18B20_RFM69CW.ino v1.5 -> v1.6.1

emonTH V1 Firmware location

Standard nodeid's: 19, 20, 21 & 22 depending on DIP switch positions:

[[19]]
    nodename = emonTH_1
    firmware = emonTH_DHT22_DS18B20_RFM69CW
    hardware = emonTH_(Node_ID_Switch_DIP1:OFF_DIP2:OFF)
    [[[rx]]]
        names = temperature, external temperature, humidity, battery
        datacode = h
        scales = 0.1,0.1,0.1,0.1
        units = C,C,%,V

EmonTx Shield

EmonTX Shield Firmware location

[[6]]
    nodename = emonTxShield
    firmware =emonTxShield
    hardware = emonTxShield
    [[[rx]]]
        names = power1, power2, power3, power4, Vrms
        datacode = h
        scales = 1,1,1,1,0.01
        units =W,W,W,W,V

4. Troubleshooting

Node data inactive or, node data does not appear for a configured node

Try replacing the datacodes = h,h,h,h,... line with datacode = h (note: datacode without an s). This will decode most of the radio packet content for the standard OpenEnergyMonitor emontx,emonth and emonpi firmwares, including historic versions.

The data still does not appear on the nodeid I expect

Both the EmonTx and EmonTH nodes have switches on their circuit boards to enable changing nodeIDs without the need to reprogram the device. Depending on the switch positions and firmware version, the EmonTx v3 can be assigned nodeID 7,8,9 or 10. The EmonTH can be assigned nodeID 19,20,21,22,23,24,25 or 26.