diff --git a/docs/wiki/configurator/power-tab.md b/docs/wiki/configurator/power-tab.md index 1cfcb58e44..679fd1cdb3 100644 --- a/docs/wiki/configurator/power-tab.md +++ b/docs/wiki/configurator/power-tab.md @@ -73,7 +73,7 @@ Multiplier: 1 = this is to fine-tune the outcome of the calculation, a value of Settings for the amperage meter to measure the current draw correctly, using this formula: $$ -Current(Amps) = \frac{ADC (mV)}{amperage\_meter\_scale} \times 10 + \frac{amperage\_meter\_offset}{1000} +Current(Amps) = \frac{ADC (mV)}{amperage\_meter\_scale \times 10} + \frac{amperage\_meter\_offset}{1000} $$ ### Scale