RP2040s don't boot if Mega's 5V rail comes up first #56

Open
baldengineer opened this issue Jul 30, 2022 · 0 comments
Open

RP2040s don't boot if Mega's 5V rail comes up first #56

baldengineer opened this issue Jul 30, 2022 · 0 comments
Labels
wontfix This will not be worked on

Comments

@baldengineer
Copy link
Owner

I think there is a back powering issue that is causing the RP2040s BOD to disable them?

In practice, this is not an issue since the Mega supply is controlled by the RP2040s.

I also suspect it is one of the buffers that are pulled-up to the Mega 5V rail while connected to the RP2040 5V rail. (maybe?)

@baldengineer baldengineer added the wontfix This will not be worked on label Jul 30, 2022