It is absolutely essential that variability be removed from any performance tests. This is achieved by controlling for
known variables in the system and fabric as best as possible. This is a simple best practices list to aid in config.
========================================================================================================================
Find matching pair of adapters and ports.
- Check the MAC address to identify the actual port number.
- Assume the lab wired Port0 to TOR0 and Port1 to TOR1 on all Hosts
- Using the same port on both physical Hosts avoids TOR0 <-> TOR1 interlink noise and ensures single hop LAT
Check which NUMA node the NIC is under.
- "Get-NetAdapterRss <NIC_NAME> | fl *", and check for the NUMA value
- NumaNode : 0
- "Get-NetAdapterRss <NIC_NAME> to view NUMA mapping.
- "Set-NetAdapterRss <NIC_NAME> -MaxProcessorNumber 9
- Or similar upper bound for the number of Cores on the associated NUMA node.
- Note that Cross NUMA traffic is VERY noisy and can result ~50% TPUT difference.
Set system in high-performance mode:
- powercfg.exe /s 8c5e7fda-e8bf-4a96-9a85-a6e23a8c635c
Disable any C-State beyond C1
- powercfg -setacvalueindex scheme_current sub_processor IDLESTATEMAX 1
- powercfg -setactive scheme_current
If using VMs or Hyper-V Containers:
- For Minimum LAT, ensure the VM or Container is on the same NUMA node.
- For Maximum TPUT, ensure the VM or Container is on a separate NUMA node from the Phsical NIC
- For the absolute maximum performance of both TPUT and LAT, ensure the VM/Container are on the
same NODE as the Physical NIC, but only if the NUMA node has 20+ Cores. This is a safe value
for 40G perf targets.
- To identify which NUMA node a VM is on, us:
- Perfmon -> Hper-V VM VID Partition -> Preferred NUMA Node Index
- If not NUMA aligned, create a DUMMY VM profile nad start, then start the VM/Container to tests
and inspect again if it landed on the desired NUMA node.