Skip to content

Latest commit

 

History

History
220 lines (165 loc) · 11.2 KB

File metadata and controls

220 lines (165 loc) · 11.2 KB
page_type languages products urlFragment extendedZipContent description
sample
csharp
cpp
cppcx
windows
windows-uwp
CustomCapability
path target
SharedContent
SharedContent
path target
LICENSE
LICENSE
Shows the use of custom capabilities.

Custom Capability sample

Shows the use of custom capabilities.

Note that the SCCD file included with this sample is not valid, but it is included for instructional purposes. If the PC is Developer Mode, the sample will deploy despite the invalid SCCD file. When writing your own app, follow the instructions in Custom Capabilities for Universal Windows Platform apps to obtain a properly-signed SCCD file.

Using a custom capability to connect to an NT service

The "Connect to an NT service" scenario uses a custom capability to control access to an NT service. For demonstration purposes, the service reads data from an imaginary device.

The scenario demonstrates the following:

  • Declaring a custom capability "microsoft.hsaTestCustomCapability_q536wpkpf5cy2" in the manifest.
  • Establishing an RPC connection to the NT service.
  • Invoking methods over RPC to initiate data collection and alter the sampling period.
  • Using an RPC callback to receive data from the imaginary device.

The service portion of this sample demonstrates the following:

  • Converting the capability string to a SID using the DeriveCapabilitySidsFromName function.
  • Using that SID to create the Security Descriptor for the RPC endpoint.

The following diagram summarizes the communication between the app and the NT service:

                  CLIENT                                   SERVER
         ------------------------                     -----------------
         |                      |                     |               |
         | CustomCapability.exe |                     | RpcServer.exe |
         |                      |                     |               |
         ------------------------                     -----------------
                    |                                         |
                    |                                         |
 Click Start button |-------------StartMetering-------------->|
                    |            [Blocking call]              |
                    |                                         |
                    |                                         |
 Updates Sample     |<------------MeteringData----------------|
 text box           |  [Sent at choosen sample period]        |
                    |                                         |
                    |                                         |
 Move the sample    |-----------SetSamplePeriod-------------->|
 period slider      |<-------SetSamplePeriod completes--------|
                    |                                         |
 Click Stop button  |-------------StopMetering--------------->|
                    |<--------StopMetering completes----------|
                    |                                         |
                    |<-------StartMetering completes----------|
                    |                                         |

Before you run this scenario, you must start the corresponding NT service.

  • Build the NT service portion of the sample, which requires that the Windows SDK for Desktop C++ Apps be installed.
  • Start the service from an elevated command prompt in one of two ways:
    • Install it as a service using rpcserver.exe -install and start it using sc start hsaservice.
    • Run the service in console mode: rpcserver.exe -console

Using a custom capability to access a custom device

A series of scenarios demonstrate how to use a custom capability to access the OSR USB FX-2 Learning Kit device. The code for the OSR USB FX-2 driver can be found in the Microsoft Windows-driver-samples repo under usb/umdf2_fx2/driver. The driver must be built for Windows 10 version 1703 or higher in order to support the custom capability used by this sample.

The "Connect to the OSR FX-2 device" scenario demonstrates the following:

  • Declaring a custom capability "microsoft.hsaTestCustomCapability_q536wpkpf5cy2" in the manifest.
  • Updating driver code or driver INF to enable access to driver interface using the custom capability
  • Using a DeviceWatcher to enumerate OSR FX-2 devices by using its device interface GUID.
  • Using the CustomDevice.FromIdAsync method to access a particular instance of the device.

The "Send IOCTLs to the device" scenario demonstrates the following:

  • Sending an IOCTL to the device to set the 7 segment LED value.
  • Sending an IOCTL to the device to get the 7 segment LED value.
    • The values and meanings of I/O control codes are defined by the device.

The "Handle asynchronous device events" scenario demonstrates the following:

  • Sending an IOCTL that does not complete until the DIP switches change.
  • Canceling the task which is waiting for the switches to change.
  • Sending an IOCTL to read the current state of the switches.
    • The values and meanings of I/O control codes are defined by the device.

To use this scenario, click "Begin Receiving Switch Change Events" and then change the DIP switches. The app displays the state of the switches when they change. You can also click "Get Switch State" to read the switch state immediately.

The "Read and Write operations" scenario demonstrates the following:

  • Writing data to the device's internal memory by writing to its OutputStream.
  • Reading data from the device's internal memory by reading from its InputStream.

Each time you click "Write Block", a message is written to the device, and each time you click "Read Block", a message is read from the device. The OSR FX-2 has four message buffers. When they are full, the next write operation will wait until a message is read, thereby freeing up a message buffer. When they are empty, the next read operation will wait until a message is written.

Raising Custom System Event Trigger

Demonstrates how to register background task with the CustomSystemEventTrigger type and raise a custom system event when an OSR FX-2 device is connected to a system. The code to raise the event is part of the OSR FX-2 driver. This enables custom devices/NT services to raise a custom system event which triggers a background task.

The code for the OSR USB FX-2 driver can be found in the Microsoft Windows-driver-samples repo under usb/kmdf_fx2/driver. The driver must be built for Windows 10 version 1803 or higher in order to support the custom system event trigger used by this sample.

Firmware access

Declaring the restricted capability smbios allows apps to read the SMBIOS. Call the GetSystemFirmwareTable and EnumSystemFirmwareTables functions with the 'RSMB' (Raw SMBIOS) table provider.

The following custom capabilities can be used for accessing UEFI variables:

UEFI access also requires the app to declare 'protectedApp' restricted capability and enable INTEGRITYCHECK for the project. This would trigger necessary store signing for protected apps during store submission. Currently the INTEGRITYCHECK can only be enabled on C++ projects properties.

UEFI variables can be accessed only when the app is being used by a user belonging to Administrators group.

Note The Windows universal samples require Visual Studio to build and Windows 10 to execute.

To obtain information about Windows 10 development, go to the Windows Dev Center

To obtain information about Microsoft Visual Studio and the tools for developing Windows apps, go to Visual Studio

Related topics

Reference

Related samples

System requirements

  • Windows 10 build 15063 or higher

Build the sample

  1. If you download the samples ZIP, be sure to unzip the entire archive, not just the folder with the sample you want to build.
  2. Start Microsoft Visual Studio and select File > Open > Project/Solution.
  3. Starting in the folder where you unzipped the samples, go to the Samples subfolder, then the subfolder for this specific sample, then the subfolder for your preferred language (C++, C#, or JavaScript). Double-click the Visual Studio 2017 Solution (.sln) file.
  4. Press Ctrl+Shift+B, or select Build > Build Solution.

Run the sample

The next steps depend on whether you just want to deploy the sample or you want to both deploy and run it.

Deploying the sample

  • Select Build > Deploy Solution.

Deploying and running the sample

  • To debug the sample and then run it, press F5 or select Debug > Start Debugging. To run the sample without debugging, press Ctrl+F5 or select Debug > Start Without Debugging.
  • To run the "Connect to an NT service" scenario, see additional instructions above.

Modifying the sample