forked from fieldtrip/fieldtrip
-
Notifications
You must be signed in to change notification settings - Fork 0
/
ft_freqgrandaverage.m
240 lines (216 loc) · 8.24 KB
/
ft_freqgrandaverage.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
function [grandavg] = ft_freqgrandaverage(cfg, varargin)
% FT_FREQGRANDAVERAGE computes the average powerspectrum or time-frequency spectrum
% over multiple subjects
%
% Use as
% [grandavg] = ft_freqgrandaverage(cfg, freq1, freq2, freq3...)
%
% The input data freq1..N are obtained from either FT_FREQANALYSIS with
% keeptrials=no or from FT_FREQDESCRIPTIVES. The configuration structure
% can contain
% cfg.keepindividual = 'yes' or 'no' (default = 'no')
% cfg.foilim = [fmin fmax] or 'all', to specify a subset of frequencies (default = 'all')
% cfg.toilim = [tmin tmax] or 'all', to specify a subset of latencies (default = 'all')
% cfg.channel = Nx1 cell-array with selection of channels (default = 'all'),
% see FT_CHANNELSELECTION for details
% cfg.parameter = string or cell-array of strings indicating which
% parameter(s) to average. default is set to
% 'powspctrm', if it is present in the data.
%
% To facilitate data-handling and distributed computing you can use
% cfg.inputfile = ...
% cfg.outputfile = ...
% If you specify one of these (or both) the input data will be read from a *.mat
% file on disk and/or the output data will be written to a *.mat file. These mat
% files should contain only a single variable, corresponding with the
% input/output structure. For this particular function, the input should be
% specified as a cell-array.
%
% See also FT_TIMELOCKGRANDAVERAGE, FT_FREQANALYSIS, FT_FREQDESCRIPTIVES,
% FT_FREQBASELINE
% FIXME averaging coherence is not possible if inputs contain different amounts of data (i.e. chan/freq/time)
% Copyright (C) 2005-2006, Robert Oostenveld
%
% This file is part of FieldTrip, see http://www.fieldtriptoolbox.org
% for the documentation and details.
%
% FieldTrip is free software: you can redistribute it and/or modify
% it under the terms of the GNU General Public License as published by
% the Free Software Foundation, either version 3 of the License, or
% (at your option) any later version.
%
% FieldTrip is distributed in the hope that it will be useful,
% but WITHOUT ANY WARRANTY; without even the implied warranty of
% MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
% GNU General Public License for more details.
%
% You should have received a copy of the GNU General Public License
% along with FieldTrip. If not, see <http://www.gnu.org/licenses/>.
%
% $Id$
% these are used by the ft_preamble/ft_postamble function and scripts
ft_revision = '$Id$';
ft_nargin = nargin;
ft_nargout = nargout;
% do the general setup of the function
ft_defaults
ft_preamble init
ft_preamble debug
ft_preamble loadvar varargin
ft_preamble provenance varargin
ft_preamble trackconfig
% the ft_abort variable is set to true or false in ft_preamble_init
if ft_abort
return
end
% check if the input data is valid for this function
for i=1:length(varargin)
varargin{i} = ft_checkdata(varargin{i}, 'datatype', 'freq', 'feedback', 'no');
end
% check if the input cfg is valid for this function
cfg = ft_checkconfig(cfg, 'forbidden', {'channels'}); % prevent accidental typos, see issue 1729
% set the defaults
cfg.keepindividual = ft_getopt(cfg, 'keepindividual', 'no');
cfg.channel = ft_getopt(cfg, 'channel', 'all');
cfg.foilim = ft_getopt(cfg, 'foilim', 'all');
cfg.toilim = ft_getopt(cfg, 'toilim', 'all');
cfg.parameter = ft_getopt(cfg, 'parameter', []);
if isempty(cfg.parameter) && isfield(varargin{1}, 'powspctrm')
cfg.parameter = 'powspctrm';
elseif isempty(cfg.parameter)
ft_error('you should specify a valid parameter to average');
end
if ischar(cfg.parameter)
cfg.parameter = {cfg.parameter};
end
Nsubj = length(varargin);
dimord = varargin{1}.dimord;
hasfreq = ~isempty(strfind(varargin{i}.dimord, 'freq')); % this should always be true
hastime = ~isempty(strfind(varargin{i}.dimord, 'time'));
hasrpt = ~isempty(strfind(varargin{i}.dimord, 'rpt'));
hastap = ~isempty(strfind(varargin{i}.dimord, 'tap'));
% check whether the input data is suitable
if hasrpt
ft_error('the input data of each subject should be an average, use FT_FREQDESCRIPTIVES first');
end
if hastap
ft_error('multiple tapers in the input are not supported');
end
if ischar(cfg.foilim) && strcmp(cfg.foilim, 'all')
fbeg = -inf;
fend = inf;
else
fbeg = cfg.foilim(1);
fend = cfg.foilim(2);
end
if ischar(cfg.toilim) && strcmp(cfg.toilim, 'all')
tbeg = -inf;
tend = inf;
else
tbeg = cfg.toilim(1);
tend = cfg.toilim(2);
end
% select the data in all inputs
for k=1:numel(cfg.parameter)
% determine which channels, frequencies and latencies are available for all inputs
for i=1:Nsubj
cfg.channel = ft_channelselection(cfg.channel, varargin{i}.label);
if hasfreq
fbeg = max(fbeg, varargin{i}.freq(1 ));
fend = min(fend, varargin{i}.freq(end));
end
if hastime
tbeg = max(tbeg, varargin{i}.time(1 ));
tend = min(tend, varargin{i}.time(end));
end
end
cfg.foilim = [fbeg fend];
cfg.toilim = [tbeg tend];
% pick the selections
for i=1:Nsubj
if ~isfield(varargin{i}, cfg.parameter{k})
ft_error('the field %s is not present in data structure %d', cfg.parameter{k}, i);
end
[dum, chansel] = match_str(cfg.channel, varargin{i}.label);
varargin{i}.label = varargin{i}.label(chansel);
if hasfreq
freqsel = nearest(varargin{i}.freq, fbeg):nearest(varargin{i}.freq, fend);
varargin{i}.freq = varargin{i}.freq(freqsel);
end
if hastime
timesel = nearest(varargin{i}.time, tbeg):nearest(varargin{i}.time, tend);
varargin{i}.time = varargin{i}.time(timesel);
end
% select the overlapping samples in the power spectrum
switch dimord
case 'chan_freq'
varargin{i}.(cfg.parameter{k}) = varargin{i}.(cfg.parameter{k})(chansel,freqsel);
case 'chan_freq_time'
varargin{i}.(cfg.parameter{k}) = varargin{i}.(cfg.parameter{k})(chansel,freqsel,timesel);
case {'rpt_chan_freq' 'rpttap_chan_freq' 'subj_chan_freq'}
varargin{i}.(cfg.parameter{k}) = varargin{i}.(cfg.parameter{k})(:,chansel,freqsel);
case {'rpt_chan_freq_time' 'rpttap_chan_freq_time' 'subj_chan_freq_time'}
varargin{i}.(cfg.parameter{k}) = varargin{i}.(cfg.parameter{k})(:,chansel,freqsel,timesel);
otherwise
ft_error('unsupported dimord');
end
end % for i = subject
end % for k = parameter
% determine the size of the data to be averaged
dim = cell(1,numel(cfg.parameter));
for k=1:numel(cfg.parameter)
dim{k} = size(varargin{1}.(cfg.parameter{k}));
end
% give some feedback on the screen
if strcmp(cfg.keepindividual, 'no')
for k=1:numel(cfg.parameter)
ft_info('computing average %s over %d subjects\n', cfg.parameter{k}, Nsubj);
end
else
for k=1:numel(cfg.parameter)
ft_info('not computing average, but keeping individual %s for %d subjects\n', cfg.parameter{k}, Nsubj);
end
end
% allocate memory to hold the data and collect it
for k=1:numel(cfg.parameter)
if strcmp(cfg.keepindividual, 'no')
tmp = zeros(dim{k});
for s=1:Nsubj
tmp = tmp + varargin{s}.(cfg.parameter{k})./Nsubj; % do a weighted running sum
end
elseif strcmp(cfg.keepindividual, 'yes')
tmp = zeros([Nsubj dim{k}]);
for s=1:Nsubj
tmp(s,:,:,:,:) = varargin{s}.(cfg.parameter{k});
end
end
grandavg.(cfg.parameter{k}) = tmp;
end
% collect the output data
grandavg.label = varargin{1}.label;
grandavg.freq = varargin{1}.freq;
if isfield(varargin{1}, 'time')
% remember the time axis
grandavg.time = varargin{1}.time;
end
if isfield(varargin{1}, 'labelcmb')
grandavg.labelcmb = varargin{1}.labelcmb;
end
if isfield(varargin{1}, 'grad')
ft_warning('discarding gradiometer information because it cannot be averaged');
end
if isfield(varargin{1}, 'elec')
ft_warning('discarding electrode information because it cannot be averaged');
end
if strcmp(cfg.keepindividual, 'yes')
grandavg.dimord = ['subj_',varargin{1}.dimord];
elseif strcmp(cfg.keepindividual, 'no')
grandavg.dimord = varargin{1}.dimord;
end
% do the general cleanup and bookkeeping at the end of the function
ft_postamble debug
ft_postamble trackconfig
ft_postamble previous varargin
ft_postamble provenance grandavg
ft_postamble history grandavg
ft_postamble savevar grandavg