From fc63511ba1c28c53df5e041255b3911623ea9406 Mon Sep 17 00:00:00 2001 From: David Jansen Date: Thu, 12 Sep 2024 15:27:55 +0000 Subject: [PATCH] Update 'docs' folder with issue890_HOMProject_FloorHeating and delete old branches. --- .../AixLib.Fluid/AixLib.Fluid-check_log.txt | 3562 +++-------------- .../AixLib.Fluid/AixLib.Fluid-error_log.txt | 3562 +++-------------- .../AixLib.ThermalZones-check_log.txt | 22 +- .../AixLib.ThermalZones-error_log.txt | 22 +- .../naming_violations.txt | 1778 ++++---- 5 files changed, 1905 insertions(+), 7041 deletions(-) diff --git a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-check_log.txt b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-check_log.txt index 298042e46b..e93ea3d44e 100644 --- a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-check_log.txt +++ b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-check_log.txt @@ -1,3061 +1,4 @@ -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom: -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: circuits.ufhEle.vol.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: dOut = 0 -Check is assuming: A = 0 -Check is assuming: spacing = 0 -Warning: Current version of the Modelica translator can only handle -array of components with fixed size. -But component ports_a had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 -But component ports_b had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 -But component circuits had non-fixed array dimensions [nCircuits]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 -But component theColConFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColRadFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColRadCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColConCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -All variables used in size expressions must be declared as constants or parameters. -Unspecified size for array of records ports_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ports_b; using default size for check. This must be specified before using the model. -Unspecified size for array of records circuits; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColConFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColRadFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColRadCei.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColConCei.port_a; using default size for check. This must be specified before using the model. -Warning: Non-literal value. -In nominal attribute for circuits[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].vol.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].vol.ports[2].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for circuits[1].val.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.val.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].val.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.val.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.resPip.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.resPip.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Check is assuming: circuits[1].length = 0 -Check is assuming: thicknessPipe = 0 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -The model contained invalid expressions. -Check of class aborted. -Warning: WARNINGS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem: -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: distributor.volSup.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: distributor.volRet.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: ufhRoom.circuits.ufhEle.vol.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: nZones = 1 -Check is assuming: dOut = fill(0, 1) -Check is assuming: A = fill(0, 1) -Check is assuming: Spacing = fill(0, 1) -Warning: Current version of the Modelica translator can only handle -array of components with fixed size. -But component distributor.volSup.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 -But component distributor.volSup.dynBal.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 -But component distributor.volRet.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 -But component distributor.volRet.dynBal.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 -But component distributor.portsCirSup had non-fixed array dimensions [n]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 66 -But component distributor.portsCirRet had non-fixed array dimensions [n]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 77 -But component ufhRoom[1].ports_a had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 -But component ufhRoom[1].ports_b had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 -But component ufhRoom[1].circuits had non-fixed array dimensions [nCircuits]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 -But component ufhRoom[1].theColConFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColRadFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColRadCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColConCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -All variables used in size expressions must be declared as constants or parameters. -Unspecified size for array of records distributor.volSup.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volSup.dynBal.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volRet.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volRet.dynBal.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.portsCirSup; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.portsCirRet; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].ports_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].ports_b; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].circuits; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColConFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColRadFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColRadCei.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColConCei.port_a; using default size for check. This must be specified before using the model. -Warning: Non-literal value. -In nominal attribute for port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for TFlow.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TFlow.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for TFlow.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TFlow.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for TReturn.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TReturn.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for TReturn.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TReturn.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.dynBal.hOut. -Ignoring nominal attribute. -In class Modelica.Blocks.Interfaces. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 -Used in component distributor.volSup.dynBal. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.dynBal.hOut. -Ignoring nominal attribute. -In class Modelica.Blocks.Interfaces. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 -Used in component distributor.volRet.dynBal. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volSup.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.dynBal.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volSup.dynBal.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volRet.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.dynBal.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volRet.dynBal.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[2].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].val.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.val.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].val.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.val.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.resPip.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.resPip.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Check is assuming: ufhRoom[1].circuits[1].length = 0 -Check is assuming: thicknessPipe = fill(0, 1) -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -The model contained invalid expressions. -Check of class aborted. -Warning: WARNINGS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH_WODis -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH_WODis: -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as Attic_Ro2Lf5 attic_2Ro_5Rooms in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[1].TSup_nominal.displayUnit -Additional warnings of this type will not be written. -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[2].TSup_nominal.displayUnit -Additional warnings of this type will not be written. -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Inconsistency for connectors dimensioned using parameter with annotation(Dialog(connectorSizing=true)). - Some connector elements are not connected. -This is either because the connections and/or parameters has been edited textually to an inconsistent state - or because the default for the parameter is not 0. The unconnected connectors are: - wholeHouseBuildingEnvelope.attic_2Ro_5Rooms.ports[1] - wholeHouseBuildingEnvelope.attic_2Ro_5Rooms.ports[2] - -Warning: For variable wholeHouseBuildingEnvelope.calcMethodIn - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomParams.mo at line 30, and used in component wholeHouseBuildingEnvelope.PartialRoomParams. -Type inconsistent definition equation: - wholeHouseBuildingEnvelope.calcMethodIn = 1; -Warning: The types of the operands in (wholeHouseBuildingEnvelope.calcMethodIn) = (1) -are Enumeration and Integer, but they must be compatible. -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[1].TSup_nominal -Additional warnings of this type will not be written. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Error: The following parameters don't have any value: - underfloorHeatingSystem.m_flow_nominal - underfloorHeatingSystem.raiseErrorForMaxVelocity - underfloorHeatingSystem.sheathingMaterial.lambda - underfloorHeatingSystem.thicknessSheathing - underfloorHeatingSystem.ufhRoom[1].circuits[1].length - underfloorHeatingSystem.ufhRoom[1].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[1].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[1].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[1].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[2].circuits[1].length - underfloorHeatingSystem.ufhRoom[2].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[2].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[2].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[2].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[2].thicknessSheathing - underfloorHeatingSystem.ufhRoom[3].circuits[1].length - underfloorHeatingSystem.ufhRoom[3].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[3].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[3].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[3].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[3].thicknessSheathing - underfloorHeatingSystem.ufhRoom[4].circuits[1].length - underfloorHeatingSystem.ufhRoom[4].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[4].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[4].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[4].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[4].thicknessSheathing - underfloorHeatingSystem.ufhRoom[5].circuits[1].length - underfloorHeatingSystem.ufhRoom[5].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[5].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[5].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[5].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[5].thicknessSheathing - underfloorHeatingSystem.ufhRoom[6].circuits[1].length - underfloorHeatingSystem.ufhRoom[6].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[6].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[6].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[6].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[6].thicknessSheathing - underfloorHeatingSystem.ufhRoom[7].circuits[1].length - underfloorHeatingSystem.ufhRoom[7].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[7].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[7].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[7].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[7].thicknessSheathing - underfloorHeatingSystem.ufhRoom[8].circuits[1].length - underfloorHeatingSystem.ufhRoom[8].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[8].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[8].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[8].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[8].thicknessSheathing - underfloorHeatingSystem.ufhRoom[9].circuits[1].length - underfloorHeatingSystem.ufhRoom[9].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[9].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[9].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[9].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[9].thicknessSheathing - underfloorHeatingSystem.ufhRoom[10].circuits[1].length - underfloorHeatingSystem.ufhRoom[10].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[10].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[10].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[10].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[10].thicknessSheathing - underfloorHeatingSystem.use_vmax - -The DAE has 12371 scalar unknowns and 12371 scalar equations. -After eliminating unused variables: - wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.thermFloor.T - wholeHouseBuildingEnvelope.upperFloor_Building.Children2.thermFloor.T - -Warning: Some connector variables are removed from the simulation problem, -since they are not used in the model. -Warning: There was an attempt to connect to thermFloor of wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom connector, as an outside connector - but the other part was disabled. That is a likely cause of a singularity -Warning: There was an attempt to connect to thermFloor of wholeHouseBuildingEnvelope.upperFloor_Building.Children2 connector, as an outside connector - but the other part was disabled. That is a likely cause of a singularity -Warning: Connector variables that are removed: -wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.thermFloor.T -wholeHouseBuildingEnvelope.upperFloor_Building.Children2.thermFloor.T -Warning: WARNINGS have been issued. -Error: ERRORS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux: -Error: Component Ceiling = << Empty >>, - but previously Ceiling = if wallTypeCeiling.n == 3 then true else false. - The components are not identical. - For element Ceiling found at - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 5 - Conflict with element from - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 15 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 2 -Error: ERRORS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple: -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: underfloorHeatingSystem.pipeMaterial.lambda = 0 -Check is assuming: underfloorHeatingSystem.ufhRoom[1].thicknessSheathing = 0 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Check is assuming: underfloorHeatingSystem.ufhRoom[1].circuits[1].length = 0 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Error: Unmatched sizes in connect(underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor); - -The first argument, underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, is a connector with sizes [1] -and the second, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor, is a connector with sizes [100]. -The model contained invalid connect statements. -Check aborted. -Warning: WARNINGS have been issued. -Error: ERRORS have been issued. - - Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH: Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. @@ -3436,14 +379,263 @@ Warning: WARNINGS have been issued. Error: ERRORS have been issued. -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA: -Warning: Index 1 of wallTypeFloor.d[2] is 2, which is outside of range 1 to 1. -Warning: Failed to expand the variable R_lambdaB -and its definition equation: -wallTypeFloor.d[2]/wallTypeFloor.lambda[2] -Failure to expand could be due to unknown sizes, which is not an error -if the sizes are given when using the component. +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem: +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: distributor.volSup.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: distributor.volRet.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: ufhRoom.circuits.ufhEle.vol.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: nZones = 1 +Check is assuming: dOut = fill(0, 1) +Check is assuming: A = fill(0, 1) +Check is assuming: Spacing = fill(0, 1) +Warning: Current version of the Modelica translator can only handle +array of components with fixed size. +But component distributor.volSup.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 +But component distributor.volSup.dynBal.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 +But component distributor.volRet.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 +But component distributor.volRet.dynBal.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 +But component distributor.portsCirSup had non-fixed array dimensions [n]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 66 +But component distributor.portsCirRet had non-fixed array dimensions [n]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 77 +But component ufhRoom[1].ports_a had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 +But component ufhRoom[1].ports_b had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 +But component ufhRoom[1].circuits had non-fixed array dimensions [nCircuits]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 +But component ufhRoom[1].theColConFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColRadFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColRadCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColConCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +All variables used in size expressions must be declared as constants or parameters. +Unspecified size for array of records distributor.volSup.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volSup.dynBal.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volRet.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volRet.dynBal.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.portsCirSup; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.portsCirRet; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].ports_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].ports_b; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].circuits; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColConFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColRadFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColRadCei.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColConCei.port_a; using default size for check. This must be specified before using the model. +Warning: Non-literal value. +In nominal attribute for port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for TFlow.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TFlow.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for TFlow.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TFlow.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for TReturn.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TReturn.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for TReturn.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TReturn.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.dynBal.hOut. +Ignoring nominal attribute. +In class Modelica.Blocks.Interfaces. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 +Used in component distributor.volSup.dynBal. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.dynBal.hOut. +Ignoring nominal attribute. +In class Modelica.Blocks.Interfaces. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 +Used in component distributor.volRet.dynBal. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volSup.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.dynBal.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volSup.dynBal.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volRet.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.dynBal.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volRet.dynBal.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[2].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].val.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.val.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].val.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.val.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.resPip.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.resPip.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Check is assuming: ufhRoom[1].circuits[1].length = 0 +Check is assuming: thicknessPipe = fill(0, 1) +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +The model contained invalid expressions. Check of class aborted. Warning: WARNINGS have been issued. @@ -3536,3 +728,243 @@ Check aborted. Warning: WARNINGS have been issued. Error: ERRORS have been issued. + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA: +Warning: Index 1 of wallTypeFloor.d[2] is 2, which is outside of range 1 to 1. +Warning: Failed to expand the variable R_lambdaB +and its definition equation: +wallTypeFloor.d[2]/wallTypeFloor.lambda[2] +Failure to expand could be due to unknown sizes, which is not an error +if the sizes are given when using the component. +Check of class aborted. +Warning: WARNINGS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple: +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: underfloorHeatingSystem.pipeMaterial.lambda = 0 +Check is assuming: underfloorHeatingSystem.ufhRoom[1].thicknessSheathing = 0 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Check is assuming: underfloorHeatingSystem.ufhRoom[1].circuits[1].length = 0 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Error: Unmatched sizes in connect(underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor); + +The first argument, underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, is a connector with sizes [1] +and the second, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor, is a connector with sizes [100]. +The model contained invalid connect statements. +Check aborted. +Warning: WARNINGS have been issued. +Error: ERRORS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom: +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: circuits.ufhEle.vol.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: dOut = 0 +Check is assuming: A = 0 +Check is assuming: spacing = 0 +Warning: Current version of the Modelica translator can only handle +array of components with fixed size. +But component ports_a had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 +But component ports_b had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 +But component circuits had non-fixed array dimensions [nCircuits]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 +But component theColConFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColRadFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColRadCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColConCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +All variables used in size expressions must be declared as constants or parameters. +Unspecified size for array of records ports_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ports_b; using default size for check. This must be specified before using the model. +Unspecified size for array of records circuits; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColConFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColRadFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColRadCei.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColConCei.port_a; using default size for check. This must be specified before using the model. +Warning: Non-literal value. +In nominal attribute for circuits[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].vol.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].vol.ports[2].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for circuits[1].val.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.val.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].val.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.val.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.resPip.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.resPip.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Check is assuming: circuits[1].length = 0 +Check is assuming: thicknessPipe = 0 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +The model contained invalid expressions. +Check of class aborted. +Warning: WARNINGS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux: +Error: Component Ceiling = << Empty >>, + but previously Ceiling = if wallTypeCeiling.n == 3 then true else false. + The components are not identical. + For element Ceiling found at + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 5 + Conflict with element from + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 15 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 2 +Error: ERRORS have been issued. + diff --git a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-error_log.txt b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-error_log.txt index 298042e46b..e93ea3d44e 100644 --- a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-error_log.txt +++ b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.Fluid/AixLib.Fluid-error_log.txt @@ -1,3061 +1,4 @@ -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom: -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: circuits.ufhEle.vol.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: dOut = 0 -Check is assuming: A = 0 -Check is assuming: spacing = 0 -Warning: Current version of the Modelica translator can only handle -array of components with fixed size. -But component ports_a had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 -But component ports_b had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 -But component circuits had non-fixed array dimensions [nCircuits]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 -But component theColConFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColRadFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColRadCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component theColConCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -All variables used in size expressions must be declared as constants or parameters. -Unspecified size for array of records ports_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ports_b; using default size for check. This must be specified before using the model. -Unspecified size for array of records circuits; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColConFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColRadFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColRadCei.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records theColConCei.port_a; using default size for check. This must be specified before using the model. -Warning: Non-literal value. -In nominal attribute for circuits[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].vol.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for circuits[1].ufhEle[1].vol.ports[2].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for circuits[1].val.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.val.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].val.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.val.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.resPip.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class circuits.resPip.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Check is assuming: circuits[1].length = 0 -Check is assuming: thicknessPipe = 0 -Warning: Non-literal value. -In nominal attribute for circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -The model contained invalid expressions. -Check of class aborted. -Warning: WARNINGS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem: -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: distributor.volSup.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: distributor.volRet.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Component type specifier BaseProperties is a partial type - It must be redeclared before being used. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 - Component context: ufhRoom.circuits.ufhEle.vol.dynBal.medium - Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: nZones = 1 -Check is assuming: dOut = fill(0, 1) -Check is assuming: A = fill(0, 1) -Check is assuming: Spacing = fill(0, 1) -Warning: Current version of the Modelica translator can only handle -array of components with fixed size. -But component distributor.volSup.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 -But component distributor.volSup.dynBal.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 -But component distributor.volRet.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 -But component distributor.volRet.dynBal.ports had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 -But component distributor.portsCirSup had non-fixed array dimensions [n]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 66 -But component distributor.portsCirRet had non-fixed array dimensions [n]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 77 -But component ufhRoom[1].ports_a had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 -But component ufhRoom[1].ports_b had non-fixed array dimensions [nPorts]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 -But component ufhRoom[1].circuits had non-fixed array dimensions [nCircuits]. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 -But component ufhRoom[1].theColConFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColRadFlo.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColRadCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -But component ufhRoom[1].theColConCei.port_a had non-fixed array dimensions [m]. - File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 -All variables used in size expressions must be declared as constants or parameters. -Unspecified size for array of records distributor.volSup.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volSup.dynBal.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volRet.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.volRet.dynBal.ports; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.portsCirSup; using default size for check. This must be specified before using the model. -Unspecified size for array of records distributor.portsCirRet; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].ports_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].ports_b; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].circuits; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColConFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColRadFlo.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColRadCei.port_a; using default size for check. This must be specified before using the model. -Unspecified size for array of records ufhRoom[1].theColConCei.port_a; using default size for check. This must be specified before using the model. -Warning: Non-literal value. -In nominal attribute for port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for TFlow.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TFlow.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for TFlow.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TFlow.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for TReturn.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TReturn.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for TReturn.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class TReturn.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.dynBal.hOut. -Ignoring nominal attribute. -In class Modelica.Blocks.Interfaces. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 -Used in component distributor.volSup.dynBal. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.dynBal.hOut. -Ignoring nominal attribute. -In class Modelica.Blocks.Interfaces. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 -Used in component distributor.volRet.dynBal. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volSup.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volSup.dynBal.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volSup.dynBal.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volRet.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for distributor.volRet.dynBal.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class distributor.volRet.dynBal.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[1].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[2].h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].val.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.val.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].val.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.val.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.port_a.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.resPip.port_a.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.port_b.h_outflow. -Ignoring nominal attribute. -In class Modelica.Media.Interfaces.Types. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 -Used in base-class ufhRoom.circuits.resPip.port_b.FluidPort. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 -Check is assuming: ufhRoom[1].circuits[1].length = 0 -Check is assuming: thicknessPipe = fill(0, 1) -Warning: Non-literal value. -In nominal attribute for ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -The model contained invalid expressions. -Check of class aborted. -Warning: WARNINGS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH_WODis -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH_WODis: -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as Attic_Ro2Lf5 attic_2Ro_5Rooms in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_a port_a in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as FluidPort_b port_b in AixLib.Fluid.Interfaces.PartialTwoPort -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as StaticTwoPortConservationEquation steBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.Fluid.Interfaces.ConservationEquation -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as ConservationEquation dynBal in AixLib.Fluid.MixingVolumes.BaseClasses.PartialMixingVolume -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as MixingVolumeMoistAir airload in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Component context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium - Component declared as VesselFluidPorts_b ports in AixLib.ThermalZones.HighOrder.Rooms.BaseClasses.PartialRoom -Warning: Base class Medium is replaceable - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo, line 196 - Context: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope.Medium -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[1].TSup_nominal.displayUnit -Additional warnings of this type will not be written. -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[2].TSup_nominal.displayUnit -Additional warnings of this type will not be written. -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[2].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[3].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[4].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[5].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[6].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[7].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[8].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[9].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[10].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Inconsistency for connectors dimensioned using parameter with annotation(Dialog(connectorSizing=true)). - Some connector elements are not connected. -This is either because the connections and/or parameters has been edited textually to an inconsistent state - or because the default for the parameter is not 0. The unconnected connectors are: - wholeHouseBuildingEnvelope.attic_2Ro_5Rooms.ports[1] - wholeHouseBuildingEnvelope.attic_2Ro_5Rooms.ports[2] - -Warning: For variable wholeHouseBuildingEnvelope.calcMethodIn - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomParams.mo at line 30, and used in component wholeHouseBuildingEnvelope.PartialRoomParams. -Type inconsistent definition equation: - wholeHouseBuildingEnvelope.calcMethodIn = 1; -Warning: The types of the operands in (wholeHouseBuildingEnvelope.calcMethodIn) = (1) -are Enumeration and Integer, but they must be compatible. -Warning: Automatically introducing 'each' in definition equation for variable: - underfloorHeatingSystem.ufhRoom[1].TSup_nominal -Additional warnings of this type will not be written. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[1].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[2].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[3].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[4].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[5].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[6].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[7].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[8].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[9].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplFlo[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatToRad.mo at line 13, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].twoStar_RadEx.radCalcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].radCalcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 11, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 8, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.calcMethod) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].calcMethod was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 20, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: For variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation - declared in class AixLib.ThermalZones.HighOrder.Components.Types, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Utilities/HeatTransfer/HeatConvInside.mo at line 22, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv. -Type inconsistent definition equation: - underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation = underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation; -Warning: The types of the operands in (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].heatConv.surfaceOrientation) = (underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation) -are Enumeration and Integer, but they must be compatible. -Variable underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1].surfaceOrientation was declared in class AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.RadiativeConvectiveHeatTransfer, /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo at line 40, and used in component underfloorHeatingSystem.ufhRoom[10].circuits[1].radConSplCei[1]. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (2) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. EN_ISO_6946_Appendix_A) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Bernd_Glueck) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. ASHRAE140_2017) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in (1) == (AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface. Custom_hCon) -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_wall_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 1 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_rad_temp -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.EN_ISO_6946_Appendix_A -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Custom_hCon -are Integer and Enumeration, but they must be compatible. -Warning: The types of the operands in 2 = AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.ASHRAE140_2017 -are Integer and Enumeration, but they must be compatible. -Error: The following parameters don't have any value: - underfloorHeatingSystem.m_flow_nominal - underfloorHeatingSystem.raiseErrorForMaxVelocity - underfloorHeatingSystem.sheathingMaterial.lambda - underfloorHeatingSystem.thicknessSheathing - underfloorHeatingSystem.ufhRoom[1].circuits[1].length - underfloorHeatingSystem.ufhRoom[1].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[1].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[1].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[1].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[2].circuits[1].length - underfloorHeatingSystem.ufhRoom[2].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[2].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[2].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[2].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[2].thicknessSheathing - underfloorHeatingSystem.ufhRoom[3].circuits[1].length - underfloorHeatingSystem.ufhRoom[3].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[3].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[3].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[3].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[3].thicknessSheathing - underfloorHeatingSystem.ufhRoom[4].circuits[1].length - underfloorHeatingSystem.ufhRoom[4].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[4].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[4].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[4].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[4].thicknessSheathing - underfloorHeatingSystem.ufhRoom[5].circuits[1].length - underfloorHeatingSystem.ufhRoom[5].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[5].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[5].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[5].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[5].thicknessSheathing - underfloorHeatingSystem.ufhRoom[6].circuits[1].length - underfloorHeatingSystem.ufhRoom[6].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[6].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[6].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[6].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[6].thicknessSheathing - underfloorHeatingSystem.ufhRoom[7].circuits[1].length - underfloorHeatingSystem.ufhRoom[7].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[7].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[7].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[7].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[7].thicknessSheathing - underfloorHeatingSystem.ufhRoom[8].circuits[1].length - underfloorHeatingSystem.ufhRoom[8].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[8].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[8].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[8].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[8].thicknessSheathing - underfloorHeatingSystem.ufhRoom[9].circuits[1].length - underfloorHeatingSystem.ufhRoom[9].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[9].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[9].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[9].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[9].thicknessSheathing - underfloorHeatingSystem.ufhRoom[10].circuits[1].length - underfloorHeatingSystem.ufhRoom[10].circuits[1].thicknessSheathing - underfloorHeatingSystem.ufhRoom[10].EN_1264.pipeMaterial.lambda - underfloorHeatingSystem.ufhRoom[10].EN_1264.sheathingMaterial.lambda - underfloorHeatingSystem.ufhRoom[10].raiseErrorForMaxVelocity - underfloorHeatingSystem.ufhRoom[10].thicknessSheathing - underfloorHeatingSystem.use_vmax - -The DAE has 12371 scalar unknowns and 12371 scalar equations. -After eliminating unused variables: - wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.thermFloor.T - wholeHouseBuildingEnvelope.upperFloor_Building.Children2.thermFloor.T - -Warning: Some connector variables are removed from the simulation problem, -since they are not used in the model. -Warning: There was an attempt to connect to thermFloor of wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom connector, as an outside connector - but the other part was disabled. That is a likely cause of a singularity -Warning: There was an attempt to connect to thermFloor of wholeHouseBuildingEnvelope.upperFloor_Building.Children2 connector, as an outside connector - but the other part was disabled. That is a likely cause of a singularity -Warning: Connector variables that are removed: -wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.thermFloor.T -wholeHouseBuildingEnvelope.upperFloor_Building.Children2.thermFloor.T -Warning: WARNINGS have been issued. -Error: ERRORS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux: -Error: Component Ceiling = << Empty >>, - but previously Ceiling = if wallTypeCeiling.n == 3 then true else false. - The components are not identical. - For element Ceiling found at - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 5 - Conflict with element from - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 15 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 2 -Error: ERRORS have been issued. - - -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple: -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling -Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns -Original declaration of R_lambdaIns: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns -Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling -Original declaration of R_lambdaCeiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling -Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster -Original declaration of R_lambdaPlaster: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster -Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling -Original declaration of alpha_Ceiling: - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 - Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling -Check is assuming: underfloorHeatingSystem.pipeMaterial.lambda = 0 -Check is assuming: underfloorHeatingSystem.ufhRoom[1].thicknessSheathing = 0 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Check is assuming: underfloorHeatingSystem.ufhRoom[1].circuits[1].length = 0 -Warning: Non-literal value. -In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. -Ignoring nominal attribute. -In class Modelica.Units.SI. - Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 -Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 -Error: Unmatched sizes in connect(underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor); - -The first argument, underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, is a connector with sizes [1] -and the second, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor, is a connector with sizes [100]. -The model contained invalid connect statements. -Check aborted. -Warning: WARNINGS have been issued. -Error: ERRORS have been issued. - - Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.OFD.OFD_UFH: Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. @@ -3436,14 +379,263 @@ Warning: WARNINGS have been issued. Error: ERRORS have been issued. -Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA -Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA: -Warning: Index 1 of wallTypeFloor.d[2] is 2, which is outside of range 1 to 1. -Warning: Failed to expand the variable R_lambdaB -and its definition equation: -wallTypeFloor.d[2]/wallTypeFloor.lambda[2] -Failure to expand could be due to unknown sizes, which is not an error -if the sizes are given when using the component. +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingSystem: +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: distributor.volSup.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: distributor.volRet.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: ufhRoom.circuits.ufhEle.vol.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: nZones = 1 +Check is assuming: dOut = fill(0, 1) +Check is assuming: A = fill(0, 1) +Check is assuming: Spacing = fill(0, 1) +Warning: Current version of the Modelica translator can only handle +array of components with fixed size. +But component distributor.volSup.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 +But component distributor.volSup.dynBal.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 +But component distributor.volRet.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 32 +But component distributor.volRet.dynBal.ports had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 73 +But component distributor.portsCirSup had non-fixed array dimensions [n]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 66 +But component distributor.portsCirRet had non-fixed array dimensions [n]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo, line 77 +But component ufhRoom[1].ports_a had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 +But component ufhRoom[1].ports_b had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 +But component ufhRoom[1].circuits had non-fixed array dimensions [nCircuits]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 +But component ufhRoom[1].theColConFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColRadFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColRadCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component ufhRoom[1].theColConCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +All variables used in size expressions must be declared as constants or parameters. +Unspecified size for array of records distributor.volSup.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volSup.dynBal.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volRet.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.volRet.dynBal.ports; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.portsCirSup; using default size for check. This must be specified before using the model. +Unspecified size for array of records distributor.portsCirRet; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].ports_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].ports_b; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].circuits; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColConFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColRadFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColRadCei.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ufhRoom[1].theColConCei.port_a; using default size for check. This must be specified before using the model. +Warning: Non-literal value. +In nominal attribute for port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for TFlow.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TFlow.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for TFlow.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TFlow.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for TReturn.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TReturn.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for TReturn.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class TReturn.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.dynBal.hOut. +Ignoring nominal attribute. +In class Modelica.Blocks.Interfaces. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 +Used in component distributor.volSup.dynBal. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.dynBal.hOut. +Ignoring nominal attribute. +In class Modelica.Blocks.Interfaces. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Blocks/Interfaces.mo, line 2 +Used in component distributor.volRet.dynBal. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/MixingVolumes/BaseClasses/PartialMixingVolume.mo, line 73 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volSup.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volSup.dynBal.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volSup.dynBal.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volRet.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for distributor.volRet.dynBal.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class distributor.volRet.dynBal.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].ufhEle[1].vol.ports[2].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].val.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.val.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].val.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.val.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.resPip.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class ufhRoom.circuits.resPip.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Check is assuming: ufhRoom[1].circuits[1].length = 0 +Check is assuming: thicknessPipe = fill(0, 1) +Warning: Non-literal value. +In nominal attribute for ufhRoom[1].circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +The model contained invalid expressions. Check of class aborted. Warning: WARNINGS have been issued. @@ -3536,3 +728,243 @@ Check aborted. Warning: WARNINGS have been issued. Error: ERRORS have been issued. + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA: +Warning: Index 1 of wallTypeFloor.d[2] is 2, which is outside of range 1 to 1. +Warning: Failed to expand the variable R_lambdaB +and its definition equation: +wallTypeFloor.d[2]/wallTypeFloor.lambda[2] +Failure to expand could be due to unknown sizes, which is not an error +if the sizes are given when using the component. +Check of class aborted. +Warning: WARNINGS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.Examples.SimpleRoom.OneRoomSimple: +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: underfloorHeatingSystem.pipeMaterial.lambda = 0 +Check is assuming: underfloorHeatingSystem.ufhRoom[1].thicknessSheathing = 0 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].val.m_flow. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.val.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.m_flow. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Check is assuming: underfloorHeatingSystem.ufhRoom[1].circuits[1].length = 0 +Warning: Non-literal value. +In nominal attribute for underfloorHeatingSystem.ufhRoom[1].circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class underfloorHeatingSystem.ufhRoom.circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +Error: Unmatched sizes in connect(underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor); + +The first argument, underfloorHeatingSystem.ufhRoom[1].circuits[1].discretizedFloorTemperatureAnalysis.port_a, is a connector with sizes [1] +and the second, underfloorHeatingSystem.ufhRoom[1].circuits[1].ufhEle.heaPorFloor, is a connector with sizes [100]. +The model contained invalid connect statements. +Check aborted. +Warning: WARNINGS have been issued. +Error: ERRORS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom: +Component type specifier BaseProperties is a partial type + It must be redeclared before being used. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/Interfaces/ConservationEquation.mo, line 81 + Component context: circuits.ufhEle.vol.dynBal.medium + Component declared as BaseProperties medium in Modelica.Media.Interfaces.PartialMedium +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 13 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.alpha_Ceiling +Warning: Modifier for final component R_lambdaIns. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 148 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaIns +Original declaration of R_lambdaIns: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 35 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaIns +Warning: Modifier for final component R_lambdaCeiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 162 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaCeiling +Original declaration of R_lambdaCeiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 37 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaCeiling +Warning: Modifier for final component R_lambdaPlaster. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 163 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.R_lambdaPlaster +Original declaration of R_lambdaPlaster: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 40 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.K_H_TypeA.R_lambdaPlaster +Warning: Modifier for final component alpha_Ceiling. This is not legal Modelica. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 149 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.UnderfloorHeatingRoom.EN_1264.alpha_Ceiling +Original declaration of alpha_Ceiling: + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo, line 12 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.TablesAndParameters.qG_TypeA.alpha_Ceiling +Check is assuming: dOut = 0 +Check is assuming: A = 0 +Check is assuming: spacing = 0 +Warning: Current version of the Modelica translator can only handle +array of components with fixed size. +But component ports_a had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 41 +But component ports_b had non-fixed array dimensions [nPorts]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo, line 47 +But component circuits had non-fixed array dimensions [nCircuits]. + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo, line 115 +But component theColConFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColRadFlo.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColRadCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +But component theColConCei.port_a had non-fixed array dimensions [m]. + File: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Thermal/HeatTransfer/Components/ThermalCollector.mo, line 4 +All variables used in size expressions must be declared as constants or parameters. +Unspecified size for array of records ports_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records ports_b; using default size for check. This must be specified before using the model. +Unspecified size for array of records circuits; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColConFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColRadFlo.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColRadCei.port_a; using default size for check. This must be specified before using the model. +Unspecified size for array of records theColConCei.port_a; using default size for check. This must be specified before using the model. +Warning: Non-literal value. +In nominal attribute for circuits[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].vol.ports[1].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for circuits[1].ufhEle[1].vol.ports[2].h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.ufhEle.vol.ports.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Vessels.mo, line 711 +Warning: Non-literal value. +In nominal attribute for circuits[1].val.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.val.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].val.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.val.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.port_a.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.resPip.port_a.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 25 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.port_b.h_outflow. +Ignoring nominal attribute. +In class Modelica.Media.Interfaces.Types. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Media/package.mo, line 3921 +Used in base-class circuits.resPip.port_b.FluidPort. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Fluid/Interfaces.mo, line 45 +Check is assuming: circuits[1].length = 0 +Check is assuming: thicknessPipe = 0 +Warning: Non-literal value. +In nominal attribute for circuits[1].resPip.dp. +Ignoring nominal attribute. +In class Modelica.Units.SI. + Near file: /opt/dymola-2022-x86_64/Modelica/Library/Modelica 4.0.0/Units.mo, line 237 +Used in base-class circuits.resPip.PartialTwoPortInterface. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/BaseClasses/PartialResistance.mo, line 3 +The model contained invalid expressions. +Check of class aborted. +Warning: WARNINGS have been issued. + + +Error in model: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux +Check of AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux: +Error: Component Ceiling = << Empty >>, + but previously Ceiling = if wallTypeCeiling.n == 3 then true else false. + The components are not identical. + For element Ceiling found at + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 5 + Conflict with element from + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo, line 15 + Context: AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.EN1264.HeatFlux + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo, line 2 +Error: ERRORS have been issued. + diff --git a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-check_log.txt b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-check_log.txt index 6d60648eff..bc02ef9438 100644 --- a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-check_log.txt +++ b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-check_log.txt @@ -1,15 +1,4 @@ -Error in model: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad -Check of AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad: -Error: Class or component 'initDynamicsAir' not found in WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 51 - Component context: wholeHouseBuildingEnvelope - Component declared as WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized - Attempted modification in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 2 -Error: ERRORS have been issued. - - Error in model: AixLib.ThermalZones.HighOrder.Examples.OFD_1Jan Check of AixLib.ThermalZones.HighOrder.Examples.OFD_1Jan: Warning: Base class Medium is not transitively non-replaceable, @@ -253,3 +242,14 @@ Check aborted. Warning: WARNINGS have been issued. Error: ERRORS have been issued. + +Error in model: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad +Check of AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad: +Error: Class or component 'initDynamicsAir' not found in WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 51 + Component context: wholeHouseBuildingEnvelope + Component declared as WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized + Attempted modification in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 2 +Error: ERRORS have been issued. + diff --git a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-error_log.txt b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-error_log.txt index 6d60648eff..bc02ef9438 100644 --- a/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-error_log.txt +++ b/docs/issue890_HOMProject_FloorHeating/Dymola_check/AixLib.ThermalZones/AixLib.ThermalZones-error_log.txt @@ -1,15 +1,4 @@ -Error in model: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad -Check of AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad: -Error: Class or component 'initDynamicsAir' not found in WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope - File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 51 - Component context: wholeHouseBuildingEnvelope - Component declared as WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized - Attempted modification in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad. - Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 2 -Error: ERRORS have been issued. - - Error in model: AixLib.ThermalZones.HighOrder.Examples.OFD_1Jan Check of AixLib.ThermalZones.HighOrder.Examples.OFD_1Jan: Warning: Base class Medium is not transitively non-replaceable, @@ -253,3 +242,14 @@ Check aborted. Warning: WARNINGS have been issued. Error: ERRORS have been issued. + +Error in model: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad +Check of AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad: +Error: Class or component 'initDynamicsAir' not found in WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope + File: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 51 + Component context: wholeHouseBuildingEnvelope + Component declared as WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized + Attempted modification in AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.OFDHeatLoad. + Near file: /builds/EBC/EBC_all/github_ci/AixLib/AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo, line 2 +Error: ERRORS have been issued. + diff --git a/docs/issue890_HOMProject_FloorHeating/naming_violations.txt b/docs/issue890_HOMProject_FloorHeating/naming_violations.txt index 66f2943206..be84dba31c 100644 --- a/docs/issue890_HOMProject_FloorHeating/naming_violations.txt +++ b/docs/issue890_HOMProject_FloorHeating/naming_violations.txt @@ -1,900 +1,888 @@ -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingElement.mo -1: Name 'length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length "Length of pipe" annotation (Dialog(group="Panel Heating")); - -2: Name 'nPipeLay' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: parameter Integer nPipeLay=if withSheathing then 2 else 1 "Number of pipe layers"; - -3: Missing documentation. Affected line: final parameter Modelica.Units.SI.Time tau=VWat*(rho_default*dis)/ m_flow_nominal; - -4: Name 'APipeInnSuf' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: final parameter Modelica.Units.SI.Area APipeInnSuf=Modelica.Constants.pi*dInn*length "Surface area inside the pipe"; - -5: Name 'hPipeInnTurb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe, Turb. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer hPipeInnTurb=2200 "Coefficient of heat transfer at the inner surface of pipe due to turbulent flow"; - -6: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare final package Medium = Medium, final energyDynamics=energyDynamics, final massDynamics=massDynamics, final p_start=p_start, final T_start=T_start, final X_start=X_start, final C_start=C_start, final C_nominal=C_nominal, final mSenFac=mSenFac, final allowFlowReversal=false, final V=VWat, final nPorts=2, final m_flow_nominal=m_flow_nominal) annotation (Placement(transformation(extent={{-10,0},{10,20}}))); - -7: Name 'nLayFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer nLayFloor( final A=A, final T_start=fill((T_start), (wallTypeFloor.n)), final wallRec=wallTypeFloor, final energyDynamics=energyDynamicsWalls) "N-Layer floor model" annotation ( Placement(transformation( extent={{-12,-12},{12,12}}, rotation=90, origin={50,70}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo +1: Name 'T_Fmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, Fmax. Affected line: parameter Modelica.Units.SI.Temperature T_Fmax "maximum surface temperature"; -8: Name 'heaPorFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a heaPorFloor "Upward heat flow to heated room" annotation (Placement(transformation( extent={{-8,92},{8,108}}), iconTransformation(extent={{-10,32},{10,52}}))); +2: Name 'T_Room' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.Temperature T_Room = 20 + 273.15 "Room temperature"; -9: Name 'pipeHeaCon' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe. Affected line: AixLib.Utilities.HeatTransfer.CylindricHeatConduction pipeHeaCon[nPipeLay]( final d_out=if withSheathing then {dOut, dOut + thicknessSheathing} else {dOut}, final lambda=if withSheathing then {pipeMaterial.lambda,sheathingMaterial.lambda} else {pipeMaterial.lambda}, final d_in=if withSheathing then {dInn, dOut} else {dInn}, each final nParallel=1, each final length=length) "Cylindric heat conduction through pipe" annotation ( Placement(transformation( extent={{10,-10},{-10,10}}, rotation=270, origin={-30,60}))); +3: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling = 5.8824 "Coefficient of heat transfer at Ceiling Surface"; -10: Missing documentation, Name 'heatConvPipeInside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Conv, Pipe, Inside. Affected line: AixLib.Utilities.HeatTransfer.HeatConv heatConvPipeInside(hCon=hPipeInnTurb, A=APipeInnSuf) annotation (Placement(transformation( extent={{-12,-12},{12,12}}, rotation=270, origin={-30,30}))); +4: Missing documentation, Name 'f_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: f_, G. Affected line: final parameter Real f_G = if s_u/T <= 0.173 then 1 else (q_Gmax - (q_Gmax - phi * B_G * (dT_HG375 / phi) ^(n_G) * 0.375 / T) * e^(-20 * (s_u / T - 0.173)^2)) / (phi * B_G * (dT_HG375 / phi) ^(n_G) * 0.375 / T); +5: Missing documentation. Affected line: final parameter Real phi = ((T_Fmax - T_Room) / d_T0)^(1.1); -AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL1IwS1Lf1At1Ro1.mo -1: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +6: Missing documentation, Name 'd_T0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: d_, T0. Affected line: final parameter Modelica.Units.SI.TemperatureDifference d_T0 = 9; -2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +7: Missing documentation, Name 'B_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: B_, G. Affected line: final parameter Real B_G = if s_u / lambda_E <= 0.0792 then tableA4.y else tableA5.y; -3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +8: Missing documentation, Name 'n_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: n_, G. Affected line: final parameter Real n_G = if s_u / lambda_E <= 0.0792 then tableA6.y else tableA7.y; -4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +9: Name 'q_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, G. Affected line: final parameter Modelica.Units.SI.HeatFlux q_G = if T <= 0.375 then phi * B_G * (dT_HG /phi)^(n_G) else phi * B_G * (dT_HG / phi) ^(n_G) * 0.375 / T * f_G "specific limiting heat flux"; -5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +10: Name 'q_Gmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Gmax. Affected line: parameter Modelica.Units.SI.HeatFlux q_Gmax "Maxium possible heat flux with given surface temperature and room temperature"; -6: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); +11: Name 'dT_HG375' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, G375. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HG375 = phi * (B_G / (B * product_ai))^(1/(1-n_G)) "maximum temperature difference at Spacing = 0.375 m"; -7: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +12: Name 'dT_HG' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, G. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HG = if T <= 0.375 then phi * (B_G / (B * product_ai))^(1/(1-n_G)) else phi * ( B_G / (B * product_ai))^(1/(1-n_G)) * f_G "maximum temperature difference between heating medium and room"; -8: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); +13: Name 'dT_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.TemperatureDifference dT_H "logarithmic temperature difference between heating medium and room"; -9: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -10: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PipeMaterials/PipeMaterialDefinition.mo +1: Missing documentation. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda; -11: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -12: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/SimpleRoom/OneRoomSimple.mo +1: Missing documentation, Name 'MediumAir' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: package MediumAir = AixLib.Media.Air; -13: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +2: Missing documentation, Name 'MediumWater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium, Water. Affected line: package MediumWater = AixLib.Media.Water; -14: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); +3: Missing documentation, Name 'area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: area. Affected line: parameter Modelica.Units.SI.Area area=20; -15: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-62,-20},{-52,38}}))); +4: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{-10,12},{10,32}}))); -16: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.vertical_wall, U_door=U_door_OD2, eps_door=eps_door_OD2, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={-29,59}, extent={{-5.00001,-29},{5.00001,29}}, rotation=270))); +5: Missing documentation, Name 'fixedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow(Q_flow=-1000) annotation (Placement(transformation(extent={{-40,74},{-20,94}}))); -17: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,4.00001}, extent={{-4.99999,-30},{5,30}}, rotation=180))); +6: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = MediumWater, nZones=1, dis=dis, Q_flow_nominal=-1.*{fixedHeatFlow.Q_flow}, A={area}, wallTypeFloor={ UnderfloorHeating.BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH()}, Ceiling={false}, wallTypeCeiling={UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy()}, Spacing={0.35}, thicknessPipe={0.002}, dOut={0.017}, withSheathing=false) annotation (Placement(transformation(extent={{-32,-64},{18,-34}}))); -18: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={32,-59}, extent={{-4.99998,-28},{4.99998,28}}, rotation=90))); +7: Missing documentation, Name 'thermalConductor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor[dis]( each G=area/dis*10.8) annotation (Placement(transformation(extent={{-4,-12},{-24,8}}))); -19: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={22,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); +8: Missing documentation, Name 'fixedHeatFlow1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow1(Q_flow=0) annotation (Placement(transformation(extent={{58,-100},{38,-80}}))); -20: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); +9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[1](each k=1) annotation (Placement(transformation(extent={{-100,-26},{-86,-12}}))); -21: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={55,59}, extent={{-2.99995,-17},{2.99997,17}}, rotation=270))); +10: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.MassFlowSource_T boundary( redeclare package Medium = MediumWater, m_flow=underfloorHeatingSystem.m_flow_nominal, T=underfloorHeatingSystem.T_Vdes, nPorts=1) annotation (Placement(transformation(extent={{-98,-58},{-78,-38}}))); -22: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); +11: Missing documentation. Affected line: AixLib.Fluid.Sources.Boundary_pT bou(redeclare package Medium = MediumWater, nPorts=1) annotation (Placement(transformation(extent={{74,-60},{54,-40}}))); -23: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); -24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PressureLoss/GetPressureLossOfUFHValve.mo +1: Name 'dp_Pipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: input Modelica.Units.SI.PressureDifference dp_Pipe "Pressure Drop in Pipe"; -25: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); +2: Name 'preDrop' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Drop. Affected line: output Modelica.Units.SI.PressureDifference preDrop "Pressure drop for the given input"; -26: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,60},{100,80}}))); +3: Name 'table_internal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Real table_internal "Table with offset for the different Kv-Values"; -27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); +4: Name 'offset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: offset. Affected line: Real offset "Output of the table"; -28: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor if not use_UFH annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); +AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow1IwL2IwS1Gr1Uf1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeatingSystemParameters.mo -1: Name 'withSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Sheathing. Affected line: parameter Boolean withSheathing = false "=false if pipe has no Sheathing" annotation (Dialog(group = "Panel Heating"), choices(checkBox=true)); +2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -2: Name 'thicknessSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness, Sheathing. Affected line: parameter Modelica.Units.SI.Thickness thicknessSheathing "Thickness of pipe sheathing" annotation (Dialog(group="Panel Heating")); +3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -3: Name 'pipeMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition pipeMaterial "Pipe Material" annotation (Dialog(group="Panel Heating"), choicesAllMatching=true); +4: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); -4: Name 'sheathingMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sheathing, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition sheathingMaterial "Sheathing Material" annotation ( Dialog(group="Panel Heating", enable=withSheathing), choicesAllMatching=true); +5: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -5: Name 'energyDynamicsWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: energy, Dynamics, Walls. Affected line: parameter Modelica.Fluid.Types.Dynamics energyDynamicsWalls= Modelica.Fluid.Types.Dynamics.DynamicFreeInitial "Type of energy balance for wall capacities: dynamic (3 initialization options) or steady state" annotation(Evaluate=true, Dialog(tab="Dynamics")); +6: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -6: Name 'raiseErrorForMaxVelocity' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: raise, Error, Velocity. Affected line: parameter Boolean raiseErrorForMaxVelocity "=true to raise error if v > v_max (0.5 m/s)" annotation(Dialog(tab="Advanced")); +7: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +8: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeatingParameters.mo -1: Name 'thicknessPipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness, Pipe. Affected line: parameter Modelica.Units.SI.Thickness thicknessPipe "Thickness of pipe wall" annotation (Dialog(group="Panel Heating")); +9: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -2: Name 'wallTypeFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Floor. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeFloor "Wall type for floor" annotation (Dialog(group="Room Specifications"), choicesAllMatching=true); +10: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-14},{-50,42}}))); -3: Name 'wallTypeCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Ceiling. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeCeiling "Wall type for ceiling" annotation (Dialog(group="Room Specifications", enable = Ceiling), choicesAllMatching=true); +11: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={23,59}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); +12: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,23}, extent={{-3,-15},{3,15}}, rotation=180))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/GroundFloorBuildingEnvelope.mo -1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); +13: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={25,-59}, extent={{-5.00002,-29},{5.00001,29}}, rotation=90))); -2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.60 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +14: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_low_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-31,60}, extent={{2,-9},{-2,9}}, rotation=90))); -3: Documentation too short, Name 'length1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length1=3.3 "l1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.groundPlate_upp_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); -4: Documentation too short, Name 'length2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length2=2.44 "l2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +16: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); -5: Documentation too short, Name 'length3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length3. Affected line: parameter Modelica.Units.SI.Length length3=1.33 "l3 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +17: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{34,-104},{54,-84}}))); -6: Documentation too short, Name 'length4' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length4. Affected line: parameter Modelica.Units.SI.Length length4=3.3 "l4 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +18: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,20},{100,40}}))); -7: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement( transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation( extent={{-109.5,-70},{-89.5,-50}}))); -8: Name 'windowarea_12' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_1. Affected line: parameter Modelica.Units.SI.Area windowarea_12=1.73 " Area Window12 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +20: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,50},{-89.5,70}}))); -9: Name 'windowarea_22' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_2. Affected line: parameter Modelica.Units.SI.Area windowarea_22=1.73 " Area Window22" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +21: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling if not use_UFH annotation (Placement(transformation(extent={{80,60},{100,80}}))); -10: Name 'windowarea_41' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_4. Affected line: parameter Modelica.Units.SI.Area windowarea_41=1.4 " Area Window41 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +22: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); -11: Name 'windowarea_51' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_51=3.46 " Area Window51" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +23: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); -12: Name 'windowarea_52' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_52=1.73 " Area Window52 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{20,80},{40,100}}))); -13: Name 'door_width_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_3. Affected line: parameter Modelica.Units.SI.Length door_width_31=1.01 "Width Door31" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); -14: Name 'door_height_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_3. Affected line: parameter Modelica.Units.SI.Length door_height_31=2.25 "Height Door31 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo +1: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization" annotation (Dialog(enable=radCalcMethod == 4)); -15: Name 'door_width_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_4. Affected line: parameter Modelica.Units.SI.Length door_width_42=1.25 "Width Door42" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); +2: Name 'radCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Calc, Method. Affected line: parameter Integer radCalcMethod=1 "Calculation method for radiation heat transfer" annotation ( Evaluate=true, Dialog(group = "Radiation exchange equation", compact=true), choices( choice=1 "No approx", choice=2 "Linear approx at wall temp", choice=3 "Linear approx at rad temp", choice=4 "Linear approx at constant T_ref", radioButtons=true)); -16: Name 'door_height_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_4. Affected line: parameter Modelica.Units.SI.Length door_height_42=2.25 "Height Door42 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +3: Name 'calcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calc, Method. Affected line: parameter Integer calcMethod=2 "Calculation method for convective heat transfer coefficient" annotation ( Dialog(descriptionLabel=true), choices( choice=1 "EN ISO 6946 Appendix A >>Flat Surfaces<<", choice=2 "By Bernd Glueck", choice=3 "Custom hCon (constant)", choice=4 "ASHRAE140-2017", radioButtons=true), Evaluate=true); -17: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); +4: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.HeatTransfer.HeatToRad twoStar_RadEx( final eps=eps, final T_ref=T_ref, final use_A_in=false, final A=A, final radCalcMethod=radCalcMethod) annotation (Placement(transformation(extent={{-10,30},{10,50}})));Utilities.HeatTransfer.HeatConvInside heatConv( final dT_small=dT_small, final A=A, final hCon_const=hCon_const, final calcMethod=calcMethod, final surfaceOrientation=surfaceOrientation) annotation (Placement(transformation( origin={-2,-40}, extent={{-12,-12},{12,12}}, rotation=180))); -18: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); +5: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a annotation (Placement(transformation(extent={{-110,-10},{-90, 10}}))); -19: Name 'Tset_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Hobby. Affected line: parameter Modelica.Units.SI.Temperature Tset_Hobby=295.15 "Tset_hobby" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -20: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/Tables/CombiTable2DParameter.mo +1: Missing documentation, Name 'tableID;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: input Modelica.Blocks.Types.ExternalCombiTable2D tableID; -21: Name 'Tset_WC' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, W. Affected line: parameter Modelica.Units.SI.Temperature Tset_WC=291.15 "Tset_WC" annotation ( Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +2: Missing documentation, Name 'u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u1. Affected line: input Real u1; -22: Name 'Tset_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Kitchen. Affected line: parameter Modelica.Units.SI.Temperature Tset_Kitchen=295.15 "Tset_kitchen" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +3: Missing documentation, Name 'u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u2. Affected line: input Real u2; -23: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 Livingroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length2, room_width=room_width, room_height=room_height, room_length=length1 + length2 + thickness_IWsimple, final solar_absorptance_OW=solar_absorptance_OW, windowarea_OW1=windowarea_11, windowarea_OW2=windowarea_12, withDoor1=false, withDoor2=false, withWindow1=true, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Livingroom, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,12},{-40,76}})));Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 Hobby( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length1, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, windowarea_OW2=windowarea_22, withDoor1=false, withDoor2=false, withWindow1=false, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Hobby, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{84,28},{46,76}})));Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 WC_Storage( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length4, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_41, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withDoor2=true, door_width_OD2=door_width_42, door_height_OD2=door_height_42, withWindow2=false, withDoor1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_WC, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{82,-36},{44,-84}})));Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 Kitchen( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final Type_Win=Type_Win, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length3 + length4 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_51, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withWindow2=true, windowarea_OW2=windowarea_52, room_lengthb=length3, withDoor1=false, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Kitchen, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,-20},{-44,-84}})));Rooms.OFD.Ow1IwL2IwS1Gr1Uf1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, room_length=length2 + length3 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withDoor1=true, door_width_OD1=door_width_31, door_height_OD1=door_height_31, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length3, withWindow1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{82,-28},{42,10}})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,60})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,26})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-4}))); +4: Name 'tableAvailable' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Available. Affected line: input Real tableAvailable "Dummy input to ensure correct sorting of function calls"; -24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-130,12},{-100,42}}))); +5: Missing documentation. Affected line: output Real y; -25: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-130,-18},{-100,12}}))); +6: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: external"C" y = ModelicaStandardTables_CombiTable2D_getValue(tableID, u1, u2) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});annotation (derivative(noDerivative=tableAvailable) = getDerTableValue);end getTableValue; -26: Missing documentation, Name 'thermCeiling_Livingroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Livingroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Livingroom if not use_UFH annotation (Placement(transformation(extent={{-100,100},{-84,118}}))); +7: Name 'getDerTableValue' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Table, Value. Affected line: function getDerTableValue "Derivative of interpolated 2-dim. table defined by matrix" extends Modelica.Icons.Function; -27: Missing documentation, Name 'thermCeiling_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Hobby. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Hobby if not use_UFH annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); +8: Missing documentation, Name 'der_u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u1. Affected line: input Real der_u1; -28: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor if not use_UFH annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); +9: Missing documentation, Name 'der_u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u2. Affected line: input Real der_u2; -29: Missing documentation, Name 'thermCeiling_WCStorage' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, W, Storage. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_WCStorage if not use_UFH annotation (Placement(transformation(extent={{20,100},{38,118}}))); +10: Missing documentation, Name 'der_y;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_y. Affected line: output Real der_y; -30: Missing documentation, Name 'thermCeiling_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Kitchen. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Kitchen if not use_UFH annotation (Placement(transformation(extent={{62,100},{80,118}}))); +11: Documentation too short, Name 'external' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: external. Affected line: external"C" der_y = ModelicaStandardTables_CombiTable2D_getDerValue(tableID, u1, u2, der_u1, der_u2) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});end getDerTableValue; -31: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,100},{120,120}}))); +12: Name 'table' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: parameter Real table[:, :] "Table matrix (grid u1 = first column, grid u2 = first row; e.g., table=[0,0;0,1])" annotation (Dialog(group="Table data definition")); -32: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] if not use_UFH "HeatPort to force a ground temperature for the ground level's floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}))); +13: Name 'tableID' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: final parameter Modelica.Blocks.Types.ExternalCombiTable2D tableID= Modelica.Blocks.Types.ExternalCombiTable2D( "NoName", "NoName", table, Modelica.Blocks.Types.Smoothness.LinearSegments) "External table object"; -33: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28})));Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); +14: Missing documentation, Name 'u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u1. Affected line: parameter Real u1; -34: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[5](redeclare final package Medium = Medium) "Inlet for ventilation" annotation (Placement( transformation(extent={{94,-78},{114,-58}}), iconTransformation(extent={ {94,-70},{108,-56}}))); +15: Missing documentation, Name 'u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u2. Affected line: parameter Real u2; -35: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[5](redeclare final package Medium = Medium) "Outlet of Ventilation" annotation (Placement( transformation(extent={{94,-94},{114,-74}}), iconTransformation(extent={ {94,-94},{108,-80}}))); +16: Missing documentation. Affected line: final parameter Real y = getTableValue(tableID, u1, u2, 1.0); -36: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/SimpleRoom/OneRoomSimple_qu.mo +1: Missing documentation, Name 'MediumAir' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: package MediumAir = AixLib.Media.Air; -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/UpperFloorBuildingEnvelope.mo -1: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2.28 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +2: Missing documentation, Name 'MediumWater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium, Water. Affected line: package MediumWater = AixLib.Media.Water; -2: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2.60 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +3: Missing documentation, Name 'area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: area. Affected line: parameter Modelica.Units.SI.Area area=20; -3: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=1 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +4: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{-10,44},{10,64}}))); -4: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2.21 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +5: Missing documentation, Name 'fixedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow(Q_flow=-1000) annotation (Placement(transformation(extent={{-40,74},{-20,94}}))); -5: Documentation too short, Name 'length5' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length5. Affected line: parameter Modelica.Units.SI.Length length5=3.3 "l5 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +6: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = MediumWater, nZones=1, dis=dis, Q_flow_nominal=-1.*{fixedHeatFlow.Q_flow}, A={area}, wallTypeFloor={ UnderfloorHeating.BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH()}, Ceiling={true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.CEpartition_EnEV2009_SM_loHalf_UFH()}, Spacing={0.35}, thicknessPipe={0.002}, dOut={0.017}, withSheathing=false) annotation (Placement(transformation(extent={{-32,-32},{18,-2}}))); -6: Documentation too short, Name 'length6' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length6. Affected line: parameter Modelica.Units.SI.Length length6=2.44 "l6 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +7: Missing documentation, Name 'thermalConductor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor[dis](each G= area/dis*10.8) annotation (Placement(transformation(extent={{-4,20},{-24,40}}))); -7: Documentation too short, Name 'length7' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length7. Affected line: parameter Modelica.Units.SI.Length length7=1.33 "l7 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +8: Missing documentation, Name 'fixedHeatFlow1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow1(Q_flow=-232) annotation (Placement(transformation(extent={{58,-100},{38,-80}}))); -8: Documentation too short, Name 'length8' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length8. Affected line: parameter Modelica.Units.SI.Length length8=3.3 "l8 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[1](each k=1) annotation (Placement(transformation(extent={{-100,6},{-86,20}}))); -9: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +10: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.MassFlowSource_T boundary( redeclare package Medium = MediumWater, use_m_flow_in=true, use_T_in=true, nPorts=1) annotation (Placement(transformation(extent={{-98,-26},{-78,-6}}))); -10: Name 'windowarea_63' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_63. Affected line: parameter Modelica.Units.SI.Area windowarea_63=1.73 " Area Window63 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +11: Missing documentation. Affected line: AixLib.Fluid.Sources.Boundary_pT bou(redeclare package Medium = MediumWater, nPorts=1) annotation (Placement(transformation(extent={{74,-28},{54,-8}}))); -11: Name 'windowarea_72' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_7. Affected line: parameter Modelica.Units.SI.Area windowarea_72=1.73 " Area Window72" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +12: Missing documentation, Name 'thermalConductor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor1 [dis](each G= area/dis*5.8824) annotation (Placement(transformation(extent={{18,-76},{-2,-56}}))); -12: Name 'windowarea_73' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_73. Affected line: parameter Modelica.Units.SI.Area windowarea_73=1.73 " Area Window73 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +13: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol1( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{36,-76},{56,-56}}))); -13: Name 'windowarea_92' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_9. Affected line: parameter Modelica.Units.SI.Area windowarea_92=1.73 " Area Window51" annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -14: Name 'windowarea_102' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_10. Affected line: parameter Modelica.Units.SI.Area windowarea_102=1.73 " Area Window102" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +AixLib/ThermalZones/HighOrder/Components/Walls/BaseClasses/ConvNLayerClearanceStar.mo +1: Name 'l' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l. Affected line: parameter Modelica.Units.SI.Length l "Length" annotation (Dialog(group="Geometry")); -15: Name 'windowarea_103' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_103. Affected line: parameter Modelica.Units.SI.Area windowarea_103=1.73 " Area Window103 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +2: Name 'clearance' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: clearance. Affected line: parameter Modelica.Units.SI.Area clearance=0 "Area of clearance" annotation (Dialog(group="Geometry")); -16: Name 'Tset_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bedroom. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bedroom=295.15 "Tset_bedroom" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +3: Name 'use_condLayers' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_cond, Layers. Affected line: parameter Boolean use_condLayers = true "Use conductive wall layers" annotation(Dialog(group = "Structure of wall layers")); -17: Name 'Tset_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children1=295.15 "Tset_children1" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +4: Name 'wallType' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallType constrainedby AixLib.DataBase.Walls.WallBaseDataDefinition "Type of wall" annotation(Dialog(group = "Structure of wall layers", enable=use_condLayers), choicesAllMatching = true, Placement(transformation(extent={{48,-98},{68,-78}}))); -18: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +5: Name 'calcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface calcMethod= AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck "Calculation method for convective heat transfer coefficient at inside surface" annotation (Dialog( group="Convection", descriptionLabel=true)); -19: Name 'Tset_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bath. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bath=297.15 "Tset_Bath" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +6: Name 'radCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer radCalcMethod= AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx "Calculation method for radiation heat transfer" annotation ( Evaluate=true, Dialog(group = "Radiation", compact=true)); -20: Name 'Tset_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children2=295.15 "Tset_children2" annotation (Dialog( group="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +7: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization" annotation (Dialog(group="Radiation", enable=radCalcMethod == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_constant_T_ref)); -21: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); +8: Name 'T0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T0. Affected line: parameter Modelica.Units.SI.Temperature T0= Modelica.Units.Conversions.from_degC(16) "Initial temperature" annotation (Dialog(group="Thermal")); -22: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); +9: Missing documentation, Name 'radPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Port. Affected line: AixLib.Utilities.Interfaces.RadPort radPort annotation (Placement(transformation(extent={{90,52},{110,72}}))); -23: Missing documentation, Name 'RoofS' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof, S. Affected line: AixLib.Utilities.Interfaces.SolarRad_in RoofS annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,44}))); +10: Missing documentation, Name 'twoStar_RadEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Star_, Ex. Affected line: AixLib.Utilities.HeatTransfer.HeatToRad twoStar_RadEx( final A=A, final eps=wallType.eps, final radCalcMethod=radCalcMethod, final T_ref=T_ref) annotation (Placement(transformation(extent={{54,30},{74,50}}))); -24: Missing documentation, Name 'RoofN' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof, N. Affected line: AixLib.Utilities.Interfaces.SolarRad_in RoofN annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,76}))); +11: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a annotation ( Placement(transformation(extent={{-110,-10},{-90,10}}), iconTransformation(extent={{-110,-10},{-90,10}}))); -25: Missing documentation, Name 'thermFloor_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bedroom[dis] annotation (Placement(transformation(extent={{-66,-122},{-46,-102}}))); +12: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b port_b annotation ( Placement(transformation(extent={{90,-10},{110,10}}), iconTransformation( extent={{90,-10},{110,10}}))); -26: Missing documentation, Name 'thermFloor_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children1[dis] annotation (Placement(transformation(extent={{-42,-120},{-22,-100}}))); +13: Missing documentation, Name 'simpleNLayer' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: simple, N, Layer. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer simpleNLayer( final A=A, each final T_start=fill(T0, n), final wallRec=wallType, final energyDynamics=energyDynamics) annotation (Placement(transformation(extent={{-14,-12},{12,12}}))); -27: Missing documentation, Name 'thermFloor_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Corridor[dis] annotation (Placement(transformation(extent={{-10,-120},{10,-100}}))); +14: Missing documentation, Name 'port_b1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: port_b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b port_b1 annotation ( Placement(transformation(extent={{-10,88},{10,108}}), iconTransformation( extent={{-12,88},{8,108}}))); -28: Missing documentation, Name 'thermFloor_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bath[dis] annotation (Placement(transformation(extent={{20,-120},{40,-100}}))); +15: Missing documentation. Affected line: parameter Modelica.Units.SI.Area A = h * l - clearance annotation(Dialog(enable = false)); -29: Missing documentation, Name 'thermFloor_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children2[dis] annotation (Placement(transformation(extent={{60,-120},{80,-100}}))); -30: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo +1: Name 'wallTypeCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Ceiling. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeCeiling "Wall type for ceiling" annotation (Dialog(group="Room Specifications", enable = Ceiling), choicesAllMatching=true); -31: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.Ow2IwL2IwS1Lf1At1Ro1 Bedroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5 + length6 + thickness_IWsimple, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length6, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_62, withWindow3=true, windowarea_RO=windowarea_63, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Bedroom, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-82,14},{-42,78}})));Rooms.Ow2IwL1IwS1Lf1At1Ro1 Children1( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_72, withWindow3=true, windowarea_RO=windowarea_73, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Children1, final T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,28},{44,76}})));Rooms.Ow2IwL1IwS1Lf1At1Ro1 Bath( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, room_length=length8, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_92, withDoor2=false, door_width_OD2=0, door_height_OD2=0, withWindow2=true, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Bath, final T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{84,-36},{46,-84}})));Rooms.Ow2IwL2IwS1Lf1At1Ro1 Children2( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length7 + length8 + thickness_IWsimple, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_102, withWindow3=true, windowarea_RO=windowarea_103, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length7, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Children2, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent= {{-84,-20},{-44,-84}})));Rooms.Ow1IwL2IwS1Lf1At1Ro1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, final solar_absorptance_OW=solar_absorptance_OW, room_length=length6 + length7 + thickness_IWsimple, room_lengthb=length7, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-28},{42,10}}))); +2: Name 'sheathingMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sheathing, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition sheathingMaterial "Sheathing Material" annotation (Dialog(group="Panel Heating", enable=withSheathing), choicesAllMatching=true); -32: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,6}))); +3: Name 'pipeMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition pipeMaterial "Pipe Material" annotation (Dialog(group="Panel Heating"), choicesAllMatching=true); -33: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-24}))); +4: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling= 5.8824 "Coefficient of heat transfer at floor surface"; -34: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-54}))); +5: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling = if wallTypeCeiling.n == 3 then true else false "false if ground plate is under panel heating" annotation (Dialog(group="Room Specifications"), choices(checkBox=true)); -35: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-84}))); +6: Name 'lambda_R' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_R = pipeMaterial.lambda "Coefficient of heat transfer of pipe material"; -36: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-148,18},{-118,48}}))); +7: Missing documentation, Name 'lambda_R0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_, R0. Affected line: constant Modelica.Units.SI.ThermalConductivity lambda_R0 = 0.35; -37: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-148,-26},{-118,4}}), iconTransformation(extent={{-130,-26},{-100,4}}))); +8: Name 's_R' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_. Affected line: parameter Modelica.Units.SI.Thickness s_R "thickness of pipe wall"; -38: Missing documentation, Name 'thermCeiling_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bedroom annotation (Placement(transformation(extent={{-98,100},{-82,118}}))); +9: Missing documentation, Name 's_R0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_, R0. Affected line: constant Modelica.Units.SI.Thickness s_R0 = 0.002; -39: Missing documentation, Name 'thermCeiling_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children1 annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); +10: Name 'withSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Sheathing. Affected line: parameter Boolean withSheathing = true "false if pipe has no Sheathing" annotation (choices(checkBox=true)); -40: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); +11: Name 'D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: D. Affected line: parameter Modelica.Units.SI.Diameter D = d_a "Outer diameter of pipe including Sheathing" annotation (Dialog(enable = withSheathing)); -41: Missing documentation, Name 'thermCeiling_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bath annotation (Placement(transformation(extent={{20,100},{38,118}}))); +12: Missing documentation, Name 'd_M' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: d_, M. Affected line: final parameter Modelica.Units.SI.Diameter d_M = if withSheathing then D else 0; -42: Missing documentation, Name 'thermCeiling_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children2 annotation (Placement(transformation(extent={{60,100},{78,118}}))); +13: Name 'lambda_M' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_, M. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_M = sheathingMaterial.lambda "Thermal Conductivity for Sheathing" annotation (Dialog(enable = withSheathing)); -43: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,-120},{120,-100}}))); +14: Name 'lambda_E' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_E=wallTypeFloor.lambda[1] "Thermal conductivity of floor screed"; -44: Missing documentation, Name 'heatStarToCombHeaters' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Heaters. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28}))); +15: Name 'R_lambdaB0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, B0. Affected line: parameter Modelica.Units.SI.ThermalInsulance R_lambdaB0=if wallTypeFloor.n == 2 then wallTypeFloor.d[2]/wallTypeFloor.lambda[2] else 0 "Thermal resistance of flooring"; -45: Name 'portConvRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Conv, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); +16: Name 'R_lambdaB' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, B. Affected line: parameter Modelica.Units.SI.ThermalInsulance R_lambdaB = if R_lambdaB0 < 0.1 then 0.1 else R_lambdaB0 "Thermal resistance of flooring used for dimensioning"; +17: Name 'R_lambdaIns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaIns= wallTypeCeiling.d[1]/wallTypeCeiling.lambda[1] "Thermal resistance of thermal insulation"; -AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL2IwS1Lf1At1Ro1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +18: Name 'R_alphaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_alpha, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_alphaCeiling = if Ceiling then 1/alpha_Ceiling else 0 "Thermal resistance at the ceiling"; -2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +19: Name 'R_lambdaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaCeiling=if Ceiling then wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] else (wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] + wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] + wallTypeCeiling.d[4]/wallTypeCeiling.lambda[4]) "Thermal resistance of ceiling"; -3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +20: Name 'R_lambdaPlaster' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Plaster. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaPlaster=if Ceiling then wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] else 0 "Thermal resistance of plaster"; -4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +21: Name 'B' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: B. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer B = if withSheathing == false then if lambda_R == 0.35 and s_R == 0.002 then 6.7 else if T <= 0.375 then (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_a / (d_a - 2 * s_R0))))^(-1) else (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * 0.375 * ( 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_a / (d_a - 2 * s_R0))))^(-1) else if T <= 0.375 then (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_M) * log(d_M / d_a) + 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_M / (d_M - 2 * s_R0))))^(-1) else (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_M) * log(d_M / d_a) + 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_M / (d_M - 2 * s_R0))))^(-1) "system dependent coefficient" annotation (Dialog(enable = false)); -5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +22: Name 'alpha_Floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Floor. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Floor = 10.8 "Coefficient of heat transfer at floor surface"; -6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +23: Missing documentation, Name 'lambda_u0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u0. Affected line: constant Modelica.Units.SI.ThermalConductivity lambda_u0 = 1; -7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); +24: Missing documentation, Name 's_u0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_u0. Affected line: constant Modelica.Units.SI.Diameter s_u0 = 0.045; -8: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); +25: Missing documentation, Name 'a_B' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_, B. Affected line: final parameter Real a_B = (1 / alpha_Floor + s_u0 / lambda_u0) / (1 / alpha_Floor + s_u0 / lambda_E + R_lambdaB); -9: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +26: Missing documentation, Name 'a_T' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_. Affected line: final parameter Real a_T = determine_aT.y; -10: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); +27: Missing documentation. Affected line: final parameter Real a_u = determine_au.y; -11: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +28: Missing documentation, Name 'a_D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_, D. Affected line: final parameter Real a_D = determine_aD.y; -12: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +29: Missing documentation, Name 'm_T' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_. Affected line: final parameter Real m_T = if T <= 0.375 then 1 - T / 0.075 else 1 - 0.375 / 0.075; -13: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +30: Missing documentation. Affected line: final parameter Real m_u = 100 * (0.045 - s_u); -14: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +31: Missing documentation, Name 'm_D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_, D. Affected line: final parameter Real m_D = 250 * (D - 0.02); -15: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +32: Name 'product_ai' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: product_ai. Affected line: final parameter Real product_ai = a_B * a_T^(m_T) * a_u^(m_u) * a_D^(m_D) "product of powers for parameters of floor heating"; -16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-88,-24},{-78,32}}))); +33: Missing documentation, Name 'K_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer K_H = if s_u > s_uStar and s_u > 0.065 then 1 / ( (1 / K_HStar) + ((s_u - s_uStar) / lambda_E)) else if T > 0.375 then B * product_ai * 0.375 / T else B * product_ai; -17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={-25,58}, extent={{-6,-33},{6,33}}, rotation=270))); +34: Missing documentation, Name 's_uStar' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Star. Affected line: protected final parameter Modelica.Units.SI.Thickness s_uStar = if T > 0.2 then (0.5 * T) else 0.1; -18: Missing documentation, Name 'inside_wall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={60,19}, extent={{-2,-15},{2,15}}, rotation=180))); +35: Missing documentation, Name 'K_HStar' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_, Star. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer K_HStar = B * a_B * a_T^(m_T) * a_u^(100*(0.045-s_uStar)) * a_D^(m_D); -19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={28,-60}, extent={{-4.00002,-26},{4.00001,26}}, rotation=90))); +36: Missing documentation. Affected line: import Modelica.Math.log; -20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); -21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final solar_absorptance=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor) if not use_UFH annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo +1: Name 'nCircuits' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Circuits. Affected line: final parameter Integer nCircuits(min=1) = integer(ceil(length/lengthMax)) "Number of circuits in one zone"; -22: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO) annotation (Placement(transformation( origin={59,59}, extent={{-3.00001,-17},{3.00002,17}}, rotation=270))); +2: Name 'lengthMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length lengthMax=120 "Maximum Length for one Circuit" annotation (Dialog(group="Panel Heating")); -23: Missing documentation, Name 'inside_wall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={60,-19}, extent={{-2,-15},{2,15}}, rotation=180))); +3: Name 'q_flow_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q. Affected line: final parameter Modelica.Units.SI.HeatFlux q_flow_nominal=Q_flow_nominal/A "Area specific heat flow rate "; -24: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); +4: Name 'dpPipe_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: parameter Modelica.Units.SI.PressureDifference dpPipe_nominal=100*length "Nominal pressure drop in every heating circuit" annotation (Dialog(group="Pressure Drop")); -25: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); +5: Name 'dpValve_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Valve. Affected line: parameter Modelica.Units.SI.PressureDifference dpValve_nominal=0 "Pressure Difference set in regulating valve for pressure equalization" annotation (Dialog(group= "Pressure Drop")); -26: Missing documentation, Name 'thermInsideWall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1a annotation (Placement(transformation(extent={{80,0},{100,20}}))); +6: Name 'dpFixed_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Fixed. Affected line: parameter Modelica.Units.SI.PressureDifference dpFixed_nominal=0 "Additional pressure drop for every heating circuit, e.g. for distributor" annotation (Dialog(group="Pressure Drop")); -27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-119.5,20},{-99.5,40}}), iconTransformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); +7: Name 'q_Gmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Gmax. Affected line: final parameter Modelica.Units.SI.HeatFlux q_Gmax=8.92*(TSurMax - TZone_nominal)^(1.1) "Maximum possible heat flux with given surface temperature and room temperature"; -28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); +8: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling "false if ground plate is under panel heating" annotation (Dialog(group="Room Specifications"), choices(checkBox=true)); -29: Missing documentation, Name 'thermInsideWall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); +9: Name 'spacing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: spacing. Affected line: parameter Modelica.Units.SI.Distance spacing "Spacing between tubes" annotation (Dialog(group="Panel Heating")); -30: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); +10: Name 'length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: final parameter Modelica.Units.SI.Length length=A/spacing "Possible pipe length for given panel heating area"; -31: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-126,-74},{-99.5,-48}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); +11: Name 'InsulationThickness' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Insulation, Thickness. Affected line: final parameter Modelica.Units.SI.Thickness InsulationThickness= wallTypeCeiling.d[1] "Thickness of thermal insulation"; +12: Name 'lambda_ins' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_ins. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_ins= wallTypeCeiling.lambda[1] "Thermal conductivity of thermal insulation"; -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/GroundFloorBuildingEnvelope.mo -1: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.60 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +13: Name 'R_lambdaIns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaIns= InsulationThickness/lambda_ins "Thermal resistance of thermal insulation"; -2: Documentation too short, Name 'length1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length1=3.3 "l1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +14: Name 'CoverThickness' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cover, Thickness. Affected line: final parameter Modelica.Units.SI.Thickness CoverThickness=wallTypeFloor.d[1] "thickness of cover above pipe"; -3: Documentation too short, Name 'length2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length2=2.44 "l2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +15: Name 'lambda_u' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_u=wallTypeFloor.lambda[1] "Thermal conductivity of wall layers above panel heating without flooring (coverage)"; -4: Documentation too short, Name 'length3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length3. Affected line: parameter Modelica.Units.SI.Length length3=1.33 "l3 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +16: Name 'lambda_E' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_E=lambda_u "Thermal conductivity of cover"; -5: Documentation too short, Name 'length4' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length4. Affected line: parameter Modelica.Units.SI.Length length4=3.3 "l4 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +17: Name 'R_lambdaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaCeiling=if Ceiling then wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] else (wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] + wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] + wallTypeCeiling.d[4]/wallTypeCeiling.lambda[4]) "Thermal resistance of ceiling"; -6: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +18: Name 'R_lambdaPlaster' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Plaster. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaPlaster=if Ceiling then wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] else 0 "Thermal resistance of plaster"; -7: Name 'windowarea_12' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_1. Affected line: parameter Modelica.Units.SI.Area windowarea_12=1.73 " Area Window12 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +19: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling = 5.8824 "Coefficient of heat transfer at Ceiling Surface"; -8: Name 'windowarea_22' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_2. Affected line: parameter Modelica.Units.SI.Area windowarea_22=1.73 " Area Window22" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +20: Name 'R_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_U=EN_1264.R_U "Thermal resistance of wall layers under panel heating"; -9: Name 'windowarea_41' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_4. Affected line: parameter Modelica.Units.SI.Area windowarea_41=1.4 " Area Window41 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +21: Name 'R_O' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_, O. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_O=EN_1264.R_O "Thermal resistance of wall layers above panel heating"; -10: Name 'windowarea_51' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_51=3.46 " Area Window51" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +22: Name 'sigma_i' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sigma_i. Affected line: final parameter Modelica.Units.SI.TemperatureDifference sigma_i=TSup_nominal - TRet_nominal "Temperature spread for room (max = 5 for room with highest heat load)" annotation (Dialog(group="Room Specifications")); -11: Name 'windowarea_52' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_52=1.73 " Area Window52 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +23: Name 'm_flow_PanelHeating' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_, Panel, Heating. Affected line: final parameter Modelica.Units.SI.MassFlowRate m_flow_PanelHeating=A* q_flow_nominal/(sigma_i*Cp_Medium)*(1 + (R_O/R_U) + (TZone_nominal - TZoneBel_nominal)/ (q_flow_nominal*R_U)) "nominal mass flow rate"; -12: Name 'door_width_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_3. Affected line: parameter Modelica.Units.SI.Length door_width_31=1.01 "Width Door31" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); +24: Name 'm_flow_Circuit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_, Circuit. Affected line: final parameter Modelica.Units.SI.MassFlowRate m_flow_Circuit= m_flow_PanelHeating/nCircuits "Nominal mass flow rate in each heating circuit"; -13: Name 'door_height_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_3. Affected line: parameter Modelica.Units.SI.Length door_height_31=2.25 "Height Door31 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +25: Name 'K_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_. Affected line: final parameter Real K_H=EN_1264.K_H "Specific parameter for dimensioning according to EN 1264 that shows the relation between temperature difference and heat flux"; -14: Name 'door_width_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_4. Affected line: parameter Modelica.Units.SI.Length door_width_42=1.25 "Width Door42" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); +26: Name 'q_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, G. Affected line: final parameter Modelica.Units.SI.HeatFlux q_G=EN_1264.q_G "specific limiting heat flux"; -15: Name 'door_height_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_4. Affected line: parameter Modelica.Units.SI.Length door_height_42=2.25 "Height Door42 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +27: Name 'dT_Hi' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, Hi. Affected line: parameter Modelica.Units.SI.TemperatureDifference dT_Hi "Nominal temperature difference between heating medium" annotation (Dialog(group="Panel Heating")); -16: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); +28: Missing documentation, Name 'dT_HU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HU= UnderfloorHeating.BaseClasses.logDT({TSup_nominal,TRet_nominal,TZoneBel_nominal}); -17: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); +29: Name 'R_add' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_add. Affected line: final parameter Modelica.Units.SI.ThermalResistance R_add=1/(K_H*(1 + R_O/R_U* dT_Hi/dT_HU)*A + A*(TZone_nominal - TZoneBel_nominal)/(R_U*dT_HU)) - 1/(A/R_O + A/R_U* dT_Hi/dT_HU) - R_pipe - 1/(2200*Modelica.Constants.pi*dInn*length) "additional thermal resistance"; -18: Name 'Tset_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Hobby. Affected line: parameter Modelica.Units.SI.Temperature Tset_Hobby=295.15 "Tset_hobby" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +30: Name 'R_pipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_pipe. Affected line: final parameter Modelica.Units.SI.ThermalResistance R_pipe=if withSheathing then (log(dOut + thicknessSheathing/dOut))/(2*sheathingMaterial.lambda* Modelica.Constants.pi*length) + (log(dOut/dInn))/(2*pipeMaterial.lambda*Modelica.Constants.pi*length) else (log(dOut/dInn))/(2*pipeMaterial.lambda*Modelica.Constants.pi*length) "thermal resistance through pipe layers"; -19: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +31: Name 'use_vmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_vmax. Affected line: parameter Integer use_vmax(min=1, max=2) "Output if v > v_max (0.5 m/s)" annotation (choices(choice=1 "Warning", choice=2 "Error")); -20: Name 'Tset_WC' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, W. Affected line: parameter Modelica.Units.SI.Temperature Tset_WC=291.15 "Tset_WC" annotation ( Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +32: Missing documentation, Name 'calculateVol' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calculate. Affected line: parameter Integer calculateVol annotation (Dialog(group="Panel Heating", descriptionLabel=true), choices( choice=1 "Calculate Water Volume with inner diameter", choice=2 "Calculate Water Volume with time constant", radioButtons=true)); -21: Name 'Tset_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Kitchen. Affected line: parameter Modelica.Units.SI.Temperature Tset_Kitchen=295.15 "Tset_kitchen" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +33: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeatingCircuit circuits[nCircuits]( each final energyDynamics=energyDynamics, each final massDynamics=massDynamics, each final p_start=p_start, each final T_start=T_start, each final X_start=X_start, each final C_start=C_start, each final C_nominal=C_nominal, each final mSenFac=mSenFac, each final dp_Pipe=dpPipe_nominal, each final dp_Valve=dpValve_nominal, each final dpFixed_nominal=dpFixed_nominal, each final TSurMax=TSurMax, each final TRoom_nominal=TZone_nominal, each final pipeMaterial=pipeMaterial, each final thicknessPipe=thicknessPipe, each final dOut=dOut, each final withSheathing=withSheathing, each final sheathingMaterial=sheathingMaterial, redeclare each final package Medium = Medium, each final A=A/nCircuits, each final dis=dis, each final raiseErrorForMaxVelocity=raiseErrorForMaxVelocity, each final spacing=spacing, each m_flow_nominal=m_flow_Circuit, each final wallTypeFloor=wallTypeFloor, each final wallTypeCeiling=wallTypeCeiling, each R_x=R_add*nCircuits) "Underloor heating circuits" annotation (Placement(transformation(extent={{-20,-20},{20,20}})));BaseClasses.EN1264.HeatFlux EN_1264( lambda_E=lambda_E, wallTypeFloor=wallTypeFloor, wallTypeCeiling=wallTypeCeiling, R_lambdaIns=R_lambdaIns, alpha_Ceiling=alpha_Ceiling, T_U=TZoneBel_nominal, d_a=dOut, lambda_R=pipeMaterial.lambda, s_R=thicknessPipe, withSheathing=withSheathing, lambda_M=sheathingMaterial.lambda, s_u=CoverThickness, T_Fmax=TSurMax, T_Room=TZone_nominal, q_Gmax=q_Gmax, dT_H=dT_Hi, Ceiling=Ceiling, R_lambdaCeiling=R_lambdaCeiling, R_lambdaPlaster=R_lambdaPlaster, D=dOut + thicknessSheathing, T=spacing) annotation (Placement(transformation(extent={{-100,-60},{-60,-40}}))); -22: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.Ow2IwL2IwS1Gr1Uf1 Livingroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length2, room_width=room_width, room_height=room_height, room_length=length1 + length2 + thickness_IWsimple, final solar_absorptance_OW=solar_absorptance_OW, windowarea_OW1=windowarea_11, windowarea_OW2=windowarea_12, withDoor1=false, withDoor2=false, withWindow1=true, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Livingroom, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-84,12},{-40,76}})));Rooms.Ow2IwL1IwS1Gr1Uf1 Hobby( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length1, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, windowarea_OW2=windowarea_22, withDoor1=false, withDoor2=false, withWindow1=false, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Hobby, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{84,28},{46,76}})));Rooms.Ow2IwL1IwS1Gr1Uf1 WC_Storage( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length4, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_41, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withDoor2=true, door_width_OD2=door_width_42, door_height_OD2=door_height_42, withWindow2=false, withDoor1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_WC, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-36},{44,-84}})));Rooms.Ow2IwL2IwS1Gr1Uf1 Kitchen( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length3 + length4 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_51, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withWindow2=true, windowarea_OW2=windowarea_52, room_lengthb=length3, withDoor1=false, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Kitchen, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent= {{-84,-20},{-44,-84}})));Rooms.Ow1IwL2IwS1Gr1Uf1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, room_length=length2 + length3 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withDoor1=true, door_width_OD1=door_width_31, door_height_OD1=door_height_31, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length3, withWindow1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-28},{42,10}}))); +34: Name 'portRadFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portRadFloor "Radiative heat port of floor" annotation (Placement(transformation(extent={{-50,90},{-30,110}}))); -23: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88}))); +35: Name 'portConFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portConFloor "Convective heat port of floor" annotation (Placement(transformation(extent={{30,90},{50,110}}))); -24: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,60}))); +36: Name 'TFloorMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMax[nCircuits](unit="K", displayUnit="degC") "Maximum floor temperature" annotation (Placement(transformation(extent={{100,78},{120,98}}))); -25: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,26}))); +37: Name 'TFloorMea' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMea[nCircuits](unit="K", displayUnit="degC") "Mean floor temperature" annotation (Placement(transformation(extent={{100,38},{120,58}}))); -26: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-16}))); +38: Name 'TFloorMin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMin[nCircuits](unit="K", displayUnit="degC") "Minimal floor temperature" annotation (Placement(transformation(extent={{100,58},{120,78}}))); -27: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-130,12},{-100,42}}))); +39: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); -28: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-130,-18},{-100,12}}))); +40: Name 'Cp_Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: parameter Modelica.Units.SI.SpecificHeatCapacity Cp_Medium=Medium.specificHeatCapacityCp(sta_default) "Specific Heat capacity of medium"; -29: Missing documentation, Name 'thermCeiling_Livingroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Livingroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Livingroom[dis] annotation (Placement(transformation(extent={{-100,100},{-84,118}}))); -30: Missing documentation, Name 'thermCeiling_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Hobby. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Hobby[dis] annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/WholeHouseBuildingEnvelope.mo +1: Name 'AirExchangeCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor. Affected line: parameter Real AirExchangeCorridor=2 "Air exchange corridors in 1/h " annotation (Dialog(group="Air Exchange Corridors", descriptionLabel=true)); -31: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor[dis] annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); +2: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.1 "Solar absoptance roof " annotation (Dialog(tab="Outer walls", group="Solar absorptance", descriptionLabel=true)); -32: Missing documentation, Name 'thermCeiling_WCStorage' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, W, Storage. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_WCStorage[dis] annotation (Placement(transformation(extent={{20,100},{38,118}}))); +3: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors=2.5 "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); -33: Missing documentation, Name 'thermCeiling_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Kitchen. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Kitchen[dis] annotation (Placement(transformation(extent={{62,100},{80,118}}))); +4: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); -34: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,100},{120,120}}))); +5: Name 'TDynVentHobby_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Hobby_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentHobby_set = 295.15 "Hobby set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -35: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5*dis] "HeatPort to force a ground temperature for the ground level's floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}))); +6: Name 'TDynVentCorridorGF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, G, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorGF_set = 291.15 "Corridor (GF) set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -36: Missing documentation, Name 'heatStarToCombHeaters' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Heaters. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28}))); +7: Name 'TDynVentWCStorage_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, W, Storage_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentWCStorage_set = 291.15 "WC / Storage room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -37: Name 'portConvRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Conv, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); +8: Name 'TDynVentKitchen_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Kitchen_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentKitchen_set = 295.15 "Kitchen set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -38: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); +9: Name 'TDynVentBedroom_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bedroom_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBedroom_set = 295.15 "Bedroom set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +10: Name 'TDynVentChildren1_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children1_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren1_set = 295.15 "Children 1 room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Sheathing_Materials/SheathingMaterialDefinition.mo -1: Missing documentation. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda; +11: Name 'TDynVentCorridorUF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorUF_set = 291.15 "Corridor (UF) set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +12: Name 'TDynVentBath_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bath_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBath_set = 297.15 "Bathroom set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/qG_TypeA.mo -1: Name 'T_Fmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, Fmax. Affected line: parameter Modelica.Units.SI.Temperature T_Fmax "maximum surface temperature"; +13: Name 'TDynVentChildren2_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children2_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren2_set = 295.15 "Children 2 room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -2: Name 'T_Room' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.Temperature T_Room = 20 + 273.15 "Room temperature"; +14: Name 'TDynVentAttic_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Attic_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentAttic_set = 288.15 "Attic set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); -3: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling = 5.8824 "Coefficient of heat transfer at Ceiling Surface"; +15: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-112,90},{-92,110}}))); -4: Missing documentation, Name 'f_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: f_, G. Affected line: final parameter Real f_G = if s_u/T <= 0.173 then 1 else (q_Gmax - (q_Gmax - phi * B_G * (dT_HG375 / phi) ^(n_G) * 0.375 / T) * e^(-20 * (s_u / T - 0.173)^2)) / (phi * B_G * (dT_HG375 / phi) ^(n_G) * 0.375 / T); +16: Missing documentation, Name 'groundFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.GroundFloorBuildingEnvelope groundFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, dis=dis, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final Tset_Livingroom=TDynVentLivingroom_set, final Tset_Hobby=TDynVentHobby_set, final Tset_Corridor=TDynVentCorridorGF_set, final Tset_WC=TDynVentWCStorage_set, final Tset_Kitchen=TDynVentKitchen_set, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-20,-74},{20,-26}}))); -5: Missing documentation. Affected line: final parameter Real phi = ((T_Fmax - T_Room) / d_T0)^(1.1); +17: Missing documentation, Name 'upperFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: upper, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.UpperFloorBuildingEnvelope upperFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final withDynamicVentilation=withDynamicVentilation, dis=dis, final solar_absorptance_RO=solar_absorptance_RO, final Tset_Bedroom=TDynVentBedroom_set, final Tset_Children1=TDynVentChildren1_set, final Tset_Corridor=TDynVentCorridorUF_set, final Tset_Bath=TDynVentBath_set, final Tset_Children2=TDynVentChildren2_set, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-24,-12},{22,34}}))); -6: Missing documentation, Name 'd_T0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: d_, T0. Affected line: final parameter Modelica.Units.SI.TemperatureDifference d_T0 = 9; +18: Missing documentation, Name 'attic_2Ro_5Rooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: attic_, Ro_5, Rooms. Affected line: AixLib.ThermalZones.HighOrder.Rooms.OFD.Attic_Ro2Lf5 attic_2Ro_5Rooms( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=TDynVentAttic_set, final solar_absorptance_RO=solar_absorptance_RO, length=10.64, width=4.75, roof_width1=3.36, roof_width2=3.36, room1_length=5.875, room2_length=3.215, room3_length=3.92, room4_length=3.215, room5_length=4.62, room1_width=2.28, room2_width=2.28, room3_width=2.28, room4_width=2.28, room5_width=2.28, alfa=1.5707963267949) annotation (Placement(transformation(extent={{-22,44},{22,82}}))); -7: Missing documentation, Name 'B_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: B_, G. Affected line: final parameter Real B_G = if s_u / lambda_E <= 0.0792 then tableA4.y else tableA5.y; +19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement( transformation(extent={{-128,66},{-100,94}}),iconTransformation(extent={{-120,60},{-100,80}}))); -8: Missing documentation, Name 'n_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: n_, G. Affected line: final parameter Real n_G = if s_u / lambda_E <= 0.0792 then tableA6.y else tableA7.y; +20: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-128,42},{-100,70}}), iconTransformation(extent={{-120,40},{-100,60}}))); -9: Name 'q_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, G. Affected line: final parameter Modelica.Units.SI.HeatFlux q_G = if T <= 0.375 then phi * B_G * (dT_HG /phi)^(n_G) else phi * B_G * (dT_HG / phi) ^(n_G) * 0.375 / T * f_G "specific limiting heat flux"; +21: Missing documentation, Name 'SolarRadiationPort_RoofS' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof, S. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofS annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,58}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,60}))); -10: Name 'q_Gmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Gmax. Affected line: parameter Modelica.Units.SI.HeatFlux q_Gmax "Maxium possible heat flux with given surface temperature and room temperature"; +22: Missing documentation, Name 'SolarRadiationPort_RoofN' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof, N. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofN annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}))); -11: Name 'dT_HG375' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, G375. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HG375 = phi * (B_G / (B * product_ai))^(1/(1-n_G)) "maximum temperature difference at Spacing = 0.375 m"; +23: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,18}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,30}))); -12: Name 'dT_HG' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, G. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HG = if T <= 0.375 then phi * (B_G / (B * product_ai))^(1/(1-n_G)) else phi * ( B_G / (B * product_ai))^(1/(1-n_G)) * f_G "maximum temperature difference between heating medium and room"; +24: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-18}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,0}))); -13: Name 'dT_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.TemperatureDifference dT_H "logarithmic temperature difference between heating medium and room"; +25: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-56}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-30}))); +26: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-60}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PressureLoss/GetPressureLossOfUFHValve.mo -1: Name 'dp_Pipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: input Modelica.Units.SI.PressureDifference dp_Pipe "Pressure Drop in Pipe"; +27: Missing documentation, Name 'varAirExchange' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange. Affected line: AixLib.ThermalZones.HighOrder.Components.DryAir.VarAirExchange varAirExchange( final V=0.5*(upperFloor_Building.Corridor.airload.V + groundFloor_Building.Corridor.airload.V), final c=cAir, final rho=denAir) annotation (Placement( transformation( extent={{-5,5},{5,-5}}, rotation=270, origin={39,-21}))); -2: Name 'preDrop' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Drop. Affected line: output Modelica.Units.SI.PressureDifference preDrop "Pressure drop for the given input"; +28: Missing documentation, Name 'AirExchangeCorridor_Source' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor_, Source. Affected line: Modelica.Blocks.Sources.Constant AirExchangeCorridor_Source(final k=AirExchangeCorridor) annotation (Placement(transformation(extent={{56,-16},{50,-10}}))); -3: Name 'table_internal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Real table_internal "Table with offset for the different Kv-Values"; +29: Name 'heatingToRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heating, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb heatingToRooms[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-112,-30},{-92,-10}}), iconTransformation(extent={{-110,-38},{-90,-18}}))); -4: Name 'offset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: offset. Affected line: Real offset "Output of the table"; +30: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] "HeatPorts to force ground temperature(s) for the ground floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}), iconTransformation(extent={{-10,-110},{10,-90}}))); +31: Missing documentation, Name 'groPlateLowPart' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Plate, Part. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer groPlateLowPart[5]( final A={groundFloor_Building.Livingroom.floor[1].Wall.A*dis, groundFloor_Building.Hobby.floor[1].Wall.A*dis,groundFloor_Building.Corridor.floor[ 1].Wall.A*dis,groundFloor_Building.WC_Storage.floor[1].Wall.A*dis, groundFloor_Building.Kitchen.floor[1].Wall.A*dis}, each final T_start=fill(TWalls_start, wallTypes.groundPlate_low_half.n), each final wallRec=wallTypes.groundPlate_low_half, each final energyDynamics=energyDynamicsWalls) if not (use_UFH) annotation ( Placement(transformation( extent={{-4,-18},{4,18}}, rotation=-90, origin={0,-86}))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL1IwS1Gr1Uf1.mo -1: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +32: Missing documentation, Name 'heatStarToCombAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Attic. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombAttic annotation (Placement(transformation( extent={{6,-5},{-6,5}}, rotation=180, origin={-36,51}))); -2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +33: Name 'uppFloDown' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Down. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a uppFloDown[5*dis] "Heat port floor of upper floor" annotation (Placement(transformation( extent={{-110,18},{-90,38}}), iconTransformation(extent={{-110,14},{-90, 34}}))); -3: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +34: Name 'groFloUp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Up. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groFloUp[5*dis] "Heat port ceiling of ground floor" annotation (Placement(transformation( extent={{-110,-4},{-90,16}}), iconTransformation(extent={{-110,-10},{-90, 10}}))); -4: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); +35: Name 'groFloDown' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Down. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groFloDown[5*dis] "Heat port floor of ground floor (towards ground plate)" annotation ( Placement(transformation(extent={{-112,-78},{-92,-58}}), iconTransformation(extent={{-110,-66},{-90,-46}}))); -5: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +36: Name 'groPlateUp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Plate, Up. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groPlateUp[5] "Heat port ground plate towards ground floor" annotation (Placement( transformation(extent={{-112,-100},{-92,-80}}), iconTransformation( extent={{-110,-90},{-90,-70}}))); -6: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); +37: Missing documentation, Name 'thermalCollectorGroundPlate' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Collector, Ground, Plate. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalCollector thermalCollectorGroundPlate[5](each m= 1) if use_UFH annotation (Placement(transformation(extent={{-32,-98},{-20,-86}}))); -7: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -8: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow1IwL2IwS1Lf1At1Ro1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -11: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -12: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -14: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); -15: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +8: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=if withWindow3 then true else false)); -16: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +9: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-12},{-50,46}}))); -17: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-60,-22},{-50,42}}))); +10: Missing documentation, Name 'inner_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inner_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inner_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={-14,58}, extent={{-3.99997,-22},{3.99999,22}}, rotation=270))); -18: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={19,57}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); +11: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,19}, extent={{-3,-15},{3,15}}, rotation=180))); -19: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={58,5}, extent={{-6,-35},{6,35}}, rotation=180))); +12: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={20,-60}, extent={{-4,-24},{4,24}}, rotation=90))); -20: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={16,-60}, extent={{-4,-24},{4,24}}, rotation=90))); +13: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); -21: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); +14: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); -22: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each outside=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-29,-65}, extent={{-3.00001,-15},{2.99998,15}}, rotation=90))); +15: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,-20}, extent={{-2.99998,-16},{2.99998,16}}, rotation=180))); -23: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); +16: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.vertical_wall, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={58,59}, extent={{-2.99997,-16},{2.99999,16}}, rotation=270))); -24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); +17: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); -25: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); +18: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,0},{100,20}}))); -26: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); -27: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={50.5,99}, extent={{-10,-10},{10,10}}, rotation=270))); +20: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); -28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); +21: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); -29: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); +22: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor if not use_UFH annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); +23: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); -AixLib/Systems/BuildingEnergySystem/BuildingEnergySystem.mo -1: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: BoundaryConditions.WeatherData.Old.WeatherTRY.Weather Weather( Latitude=49.5, Longitude=8.5, GroundReflection=0.2, tableName="wetter", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, SOD=AixLib.DataBase.Weather.SurfaceOrientation.SurfaceOrientationData_N_E_S_W_RoofN_Roof_S(), Wind_dir=false, Wind_speed=true, Air_temp=true, fileName="modelica://AixLib/Resources/WeatherData/TRY2010_12_Jahr_Modelica-Library.txt", WeatherData(tableOnFile=false, table=weatherDataDay.weatherData)) annotation (Placement(transformation(extent={{340,156},{268,204}})));ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope OFD( redeclare DataBase.Walls.Collections.OFD.WSchV1995Heavy wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare DataBase.WindowsDoors.Simple.WindowSimple_WSchV1995 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, withDynamicVentilation=true, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{200,-58}, {334,86}}))); +24: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); -2: Missing documentation, Name 'tempOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Outside. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature tempOutside annotation (Placement(transformation(extent={{10.375,-10.375},{-10.375,10.375}}, rotation=90, origin={189.625,129.625}))); +25: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{-20,80},{0,100}}), iconTransformation(extent={{-20,80},{0,100}}))); -3: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: HeatPumpSystems.HeatPumpSystem heatPumpSystem( redeclare package Medium_con = Medium_sin, redeclare package Medium_eva = Medium_sou, dataTable=AixLib.DataBase.HeatPump.EN255.Vitocal350BWH113(), use_deFro=false, massDynamics=Modelica.Fluid.Types.Dynamics.DynamicFreeInitial, energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial, refIneFre_constant=0.01, dpEva_nominal=0, deltaM_con=0.1, use_opeEnvFroRec=true, tableUpp=[-100,100; 100,100], minIceFac=0, use_chiller=true, calcPel_deFro=100, minRunTime(displayUnit="min"), minLocTime(displayUnit="min"), use_antLeg=false, use_refIne=true, initType=Modelica.Blocks.Types.Init.InitialOutput, minTimeAntLeg(displayUnit="min") = 900, scalingFactor=1, use_tableData=false, dpCon_nominal=0, use_conCap=true, CCon=3000, use_evaCap=true, CEva=3000, Q_flow_nominal=5000, cpEva=4180, cpCon=4180, use_secHeaGen=false, redeclare model TSetToNSet = Controls.HeatPump.BaseClasses.OnOffHP (hys=5), use_sec=true, QCon_nominal=10000, P_el_nominal=2500, redeclare model PerDataHea = AixLib.DataBase.HeatPump.PerformanceData.LookUpTable2D ( smoothness=Modelica.Blocks.Types.Smoothness.LinearSegments, dataTable= AixLib.DataBase.HeatPump.EN255.Vitocal350BWH113( tableP_ele=[0,-5.0,0.0,5.0,10.0,15.0; 35,3750,3750,3750,3750,3833;45,4833,4917,4958,5042,5125; 55,5583,5667,5750,5833,5958; 65,7000, 7125,7250,7417,7583]), printAsserts=false, extrapolation=false), redeclare function HeatingCurveFunction = Controls.SetPoints.Functions.HeatingCurveFunction (TDesign=328.15), use_minRunTime=true, use_minLocTime=true, use_runPerHou=true, pre_n_start=true, redeclare Fluid.Movers.Data.Pumps.Wilo.Stratos80slash1to12 perEva, redeclare Fluid.Movers.Data.Pumps.Wilo.Stratos25slash1to4 perCon, TCon_nominal=313.15, TCon_start=313.15, TEva_start=283.15, use_revHP=false, VCon=0.004, VEva=0.004) annotation (Placement(transformation(extent={{-280,-46},{-214,46}}))); -4: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Fluid.Storage.BufferStorage bufferStorage( redeclare package Medium = Medium, useHeatingCoil1=false, useHeatingCoil2=false, useHeatingRod=false, n=5, hConIn=100, hConOut=10, redeclare final model HeatTransfer = AixLib.Fluid.Storage.BaseClasses.HeatTransferBuoyancyWetter) annotation (Placement(transformation(extent={{-106,-30},{-74,10}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/Tables/CombiTable1DParameter.mo +1: Missing documentation, Name 'tableID;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: input Modelica.Blocks.Types.ExternalCombiTable1D tableID; -5: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Fluid.Sources.Boundary_pT sin( nPorts=1, redeclare package Medium = Medium_sou, p=200000, T=281.15) "Fluid sink on source side" annotation (Placement(transformation(extent={{-322,-64},{-302,-44}})));Fluid.Sources.Boundary_pT sou( use_T_in=true, nPorts=1, redeclare package Medium = Medium_sou) "Fluid source on source side" annotation (Placement(transformation(extent={{-172,-62},{-192,-42}}))); +2: Missing documentation, Name 'icol;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: icol. Affected line: input Integer icol; -6: Missing documentation, Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = Modelica.Media.Interfaces.PartialMedium annotation (choicesAllMatching=true); +3: Missing documentation. Affected line: input Real u; -7: Missing documentation, Name 'tempOutside1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Outside. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature tempOutside1(T=290.15) annotation (Placement(transformation(extent={{10.375,-10.375},{-10.375,10.375}}, rotation=180, origin={-100.375,-96.375}))); +4: Name 'tableAvailable' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Available. Affected line: input Real tableAvailable "Dummy input to ensure correct sorting of function calls"; -8: Missing documentation, Name 'tempGround' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Ground. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature tempGround[5](T=282.65) annotation (Placement(transformation( extent={{10.375,-10.375},{-10.375,10.375}}, rotation=180, origin={231.625,-86.375}))); +5: Missing documentation. Affected line: output Real y; -9: Missing documentation, Name 'NaturalVentilation' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Natural, Ventilation. Affected line: Modelica.Blocks.Sources.CombiTimeTable NaturalVentilation( columns={2,3,4,5,7}, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableOnFile=false, table=VentilationProfile.Profile) annotation(Placement(transformation(extent={{10,10}, {-10,-10}}, rotation=180, origin={151,51}))); +6: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: external"C" y = ModelicaStandardTables_CombiTable1D_getValue(tableID, icol, u) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});annotation (derivative(noDerivative=tableAvailable) = getDerTableValue);end getTableValue; +7: Name 'getDerTableValue' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Table, Value. Affected line: function getDerTableValue "Derivative of interpolated 1-dim. table defined by matrix" extends Modelica.Icons.Function; -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo -1: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling "false if ground plate is under panel heating" annotation (choices(checkBox=true)); +8: Missing documentation, Name 'der_u;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u. Affected line: input Real der_u; -2: Name 'lambda_u' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_u = lambda_E "Thermal conductivity of wall layers above panel heating without flooring (coverage)"; +9: Missing documentation, Name 'der_y;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_y. Affected line: output Real der_y; -3: Name 'T_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.Temperature T_U=293.15 "Nominal Room Temperature lying under panel heating" annotation (Dialog(group="Room Specifications")); +10: Documentation too short, Name 'external' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: external. Affected line: external"C" der_y = ModelicaStandardTables_CombiTable1D_getDerValue(tableID, icol, u, der_u) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});end getDerTableValue; -4: Name 'R_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_U = if Ceiling then R_lambdaIns + R_lambdaCeiling + R_lambdaPlaster + R_alphaCeiling else R_lambdaIns + R_lambdaCeiling + R_lambdaPlaster "Thermal resistance of wall layers under panel heating"; +11: Name 'table' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: parameter Real table[:, :] "Table matrix (grid = first column; e.g., table=[0,2])" annotation (Dialog(group="Table data definition",enable=not tableOnFile)); -5: Name 'R_O' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_, O. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_O = 1 / alpha_Floor + R_lambdaB + s_u / lambda_u "Thermal resistance of wall layers above panel heating"; +12: Name 'columns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: columns. Affected line: final parameter Integer columns[:]=2:size(table, 2) "Columns of table to be interpolated" annotation (Dialog(group="Table data interpretation")); -6: Missing documentation, Name 'q_max' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q. Affected line: final parameter Modelica.Units.SI.HeatFlux q_max = K_H * dT_H; +13: Name 'tableID' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: final parameter Modelica.Blocks.Types.ExternalCombiTable1D tableID= Modelica.Blocks.Types.ExternalCombiTable1D( "NoName", "NoName", table, columns, Modelica.Blocks.Types.Smoothness.LinearSegments) "External table object"; -7: Missing documentation, Name 'q_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_. Affected line: final parameter Modelica.Units.SI.HeatFlux q_U = 1 / R_U * (R_O * q_max + T_Room - T_U); +14: Missing documentation. Affected line: final parameter Integer n= 1; +15: Missing documentation. Affected line: parameter Real u; -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/WholeHouseBuildingEnvelope.mo -1: Name 'AirExchangeCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor. Affected line: parameter Real AirExchangeCorridor=2 "Air exchange corridors in 1/h " annotation (Dialog(group="Air Exchange Corridors", descriptionLabel=true)); +16: Missing documentation. Affected line: final parameter Real y = getTableValue(tableID, n, u, 1.0); -2: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.1 "Solar absoptance roof " annotation (Dialog(tab="Outer walls", group="Solar absorptance", descriptionLabel=true)); -3: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors=2.5 "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/GroundFloorBuildingEnvelope.mo +1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); -4: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); +2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.60 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -5: Name 'TDynVentHobby_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Hobby_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentHobby_set = 295.15 "Hobby set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +3: Documentation too short, Name 'length1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length1=3.3 "l1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -6: Name 'TDynVentCorridorGF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, G, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorGF_set = 291.15 "Corridor (GF) set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +4: Documentation too short, Name 'length2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length2=2.44 "l2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -7: Name 'TDynVentWCStorage_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, W, Storage_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentWCStorage_set = 291.15 "WC / Storage room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +5: Documentation too short, Name 'length3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length3. Affected line: parameter Modelica.Units.SI.Length length3=1.33 "l3 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -8: Name 'TDynVentKitchen_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Kitchen_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentKitchen_set = 295.15 "Kitchen set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +6: Documentation too short, Name 'length4' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length4. Affected line: parameter Modelica.Units.SI.Length length4=3.3 "l4 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Name 'TDynVentBedroom_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bedroom_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBedroom_set = 295.15 "Bedroom set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +7: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Name 'TDynVentChildren1_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children1_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren1_set = 295.15 "Children 1 room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +8: Name 'windowarea_12' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_1. Affected line: parameter Modelica.Units.SI.Area windowarea_12=1.73 " Area Window12 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -11: Name 'TDynVentCorridorUF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorUF_set = 291.15 "Corridor (UF) set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +9: Name 'windowarea_22' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_2. Affected line: parameter Modelica.Units.SI.Area windowarea_22=1.73 " Area Window22" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -12: Name 'TDynVentBath_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bath_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBath_set = 297.15 "Bathroom set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +10: Name 'windowarea_41' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_4. Affected line: parameter Modelica.Units.SI.Area windowarea_41=1.4 " Area Window41 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -13: Name 'TDynVentChildren2_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children2_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren2_set = 295.15 "Children 2 room set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +11: Name 'windowarea_51' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_51=3.46 " Area Window51" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -14: Name 'TDynVentAttic_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Attic_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentAttic_set = 288.15 "Attic set temperature for dyn. vent." annotation (Dialog(tab="Dynamic ventilation", enable=withDynamicVentilation)); +12: Name 'windowarea_52' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_52=1.73 " Area Window52 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -15: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-112,90},{-92,110}}))); +13: Name 'door_width_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_3. Affected line: parameter Modelica.Units.SI.Length door_width_31=1.01 "Width Door31" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); -16: Missing documentation, Name 'groundFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.GroundFloorBuildingEnvelope groundFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, dis=dis, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final Tset_Livingroom=TDynVentLivingroom_set, final Tset_Hobby=TDynVentHobby_set, final Tset_Corridor=TDynVentCorridorGF_set, final Tset_WC=TDynVentWCStorage_set, final Tset_Kitchen=TDynVentKitchen_set, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-20,-74},{20,-26}}))); +14: Name 'door_height_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_3. Affected line: parameter Modelica.Units.SI.Length door_height_31=2.25 "Height Door31 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -17: Missing documentation, Name 'upperFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: upper, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.UpperFloorBuildingEnvelope upperFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final withDynamicVentilation=withDynamicVentilation, dis=dis, final solar_absorptance_RO=solar_absorptance_RO, final Tset_Bedroom=TDynVentBedroom_set, final Tset_Children1=TDynVentChildren1_set, final Tset_Corridor=TDynVentCorridorUF_set, final Tset_Bath=TDynVentBath_set, final Tset_Children2=TDynVentChildren2_set, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-24,-12},{22,34}}))); +15: Name 'door_width_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_4. Affected line: parameter Modelica.Units.SI.Length door_width_42=1.25 "Width Door42" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); -18: Missing documentation, Name 'attic_2Ro_5Rooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: attic_, Ro_5, Rooms. Affected line: AixLib.ThermalZones.HighOrder.Rooms.OFD.Attic_Ro2Lf5 attic_2Ro_5Rooms( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=TDynVentAttic_set, final solar_absorptance_RO=solar_absorptance_RO, length=10.64, width=4.75, roof_width1=3.36, roof_width2=3.36, room1_length=5.875, room2_length=3.215, room3_length=3.92, room4_length=3.215, room5_length=4.62, room1_width=2.28, room2_width=2.28, room3_width=2.28, room4_width=2.28, room5_width=2.28, alfa=1.5707963267949) annotation (Placement(transformation(extent={{-22,44},{22,82}}))); +16: Name 'door_height_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_4. Affected line: parameter Modelica.Units.SI.Length door_height_42=2.25 "Height Door42 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement( transformation(extent={{-128,66},{-100,94}}),iconTransformation(extent={{-120,60},{-100,80}}))); +17: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); -20: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-128,42},{-100,70}}), iconTransformation(extent={{-120,40},{-100,60}}))); +18: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); -21: Missing documentation, Name 'SolarRadiationPort_RoofS' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof, S. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofS annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,58}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,60}))); +19: Name 'Tset_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Hobby. Affected line: parameter Modelica.Units.SI.Temperature Tset_Hobby=295.15 "Tset_hobby" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -22: Missing documentation, Name 'SolarRadiationPort_RoofN' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof, N. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofN annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}))); +20: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -23: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,18}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,30}))); +21: Name 'Tset_WC' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, W. Affected line: parameter Modelica.Units.SI.Temperature Tset_WC=291.15 "Tset_WC" annotation ( Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); -24: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-18}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,0}))); +22: Name 'Tset_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Kitchen. Affected line: parameter Modelica.Units.SI.Temperature Tset_Kitchen=295.15 "Tset_kitchen" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -25: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-56}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-30}))); +23: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 Livingroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length2, room_width=room_width, room_height=room_height, room_length=length1 + length2 + thickness_IWsimple, final solar_absorptance_OW=solar_absorptance_OW, windowarea_OW1=windowarea_11, windowarea_OW2=windowarea_12, withDoor1=false, withDoor2=false, withWindow1=true, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Livingroom, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,12},{-40,76}})));Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 Hobby( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length1, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, windowarea_OW2=windowarea_22, withDoor1=false, withDoor2=false, withWindow1=false, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Hobby, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{84,28},{46,76}})));Rooms.OFD.Ow2IwL1IwS1Gr1Uf1 WC_Storage( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length4, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_41, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withDoor2=true, door_width_OD2=door_width_42, door_height_OD2=door_height_42, withWindow2=false, withDoor1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_WC, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{82,-36},{44,-84}})));Rooms.OFD.Ow2IwL2IwS1Gr1Uf1 Kitchen( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final Type_Win=Type_Win, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, room_length=length3 + length4 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_51, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withWindow2=true, windowarea_OW2=windowarea_52, room_lengthb=length3, withDoor1=false, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Kitchen, T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,-20},{-44,-84}})));Rooms.OFD.Ow1IwL2IwS1Gr1Uf1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, room_length=length2 + length3 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withDoor1=true, door_width_OD1=door_width_31, door_height_OD1=door_height_31, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length3, withWindow1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{82,-28},{42,10}})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,60})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,26})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-4}))); -26: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-60}))); +24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-130,12},{-100,42}}))); -27: Missing documentation, Name 'varAirExchange' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange. Affected line: AixLib.ThermalZones.HighOrder.Components.DryAir.VarAirExchange varAirExchange( final V=0.5*(upperFloor_Building.Corridor.airload.V + groundFloor_Building.Corridor.airload.V), final c=cAir, final rho=denAir) annotation (Placement( transformation( extent={{-5,5},{5,-5}}, rotation=270, origin={39,-21}))); +25: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-130,-18},{-100,12}}))); -28: Missing documentation, Name 'AirExchangeCorridor_Source' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor_, Source. Affected line: Modelica.Blocks.Sources.Constant AirExchangeCorridor_Source(final k=AirExchangeCorridor) annotation (Placement(transformation(extent={{56,-16},{50,-10}}))); +26: Missing documentation, Name 'thermCeiling_Livingroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Livingroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Livingroom if not use_UFH annotation (Placement(transformation(extent={{-100,100},{-84,118}}))); -29: Name 'heatingToRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heating, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb heatingToRooms[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-112,-30},{-92,-10}}), iconTransformation(extent={{-110,-38},{-90,-18}}))); +27: Missing documentation, Name 'thermCeiling_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Hobby. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Hobby if not use_UFH annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); -30: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] "HeatPorts to force ground temperature(s) for the ground floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}), iconTransformation(extent={{-10,-110},{10,-90}}))); +28: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor if not use_UFH annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); -31: Missing documentation, Name 'groPlateLowPart' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Plate, Part. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer groPlateLowPart[5]( final A={groundFloor_Building.Livingroom.floor[1].Wall.A*dis, groundFloor_Building.Hobby.floor[1].Wall.A*dis,groundFloor_Building.Corridor.floor[ 1].Wall.A*dis,groundFloor_Building.WC_Storage.floor[1].Wall.A*dis, groundFloor_Building.Kitchen.floor[1].Wall.A*dis}, each final T_start=fill(TWalls_start, wallTypes.groundPlate_low_half.n), each final wallRec=wallTypes.groundPlate_low_half, each final energyDynamics=energyDynamicsWalls) if not (use_UFH) annotation ( Placement(transformation( extent={{-4,-18},{4,18}}, rotation=-90, origin={0,-86}))); +29: Missing documentation, Name 'thermCeiling_WCStorage' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, W, Storage. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_WCStorage if not use_UFH annotation (Placement(transformation(extent={{20,100},{38,118}}))); -32: Missing documentation, Name 'heatStarToCombAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Attic. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombAttic annotation (Placement(transformation( extent={{6,-5},{-6,5}}, rotation=180, origin={-36,51}))); +30: Missing documentation, Name 'thermCeiling_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Kitchen. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Kitchen if not use_UFH annotation (Placement(transformation(extent={{62,100},{80,118}}))); -33: Name 'uppFloDown' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Down. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a uppFloDown[5*dis] "Heat port floor of upper floor" annotation (Placement(transformation( extent={{-110,18},{-90,38}}), iconTransformation(extent={{-110,14},{-90, 34}}))); +31: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,100},{120,120}}))); -34: Name 'groFloUp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Up. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groFloUp[5*dis] "Heat port ceiling of ground floor" annotation (Placement(transformation( extent={{-110,-4},{-90,16}}), iconTransformation(extent={{-110,-10},{-90, 10}}))); +32: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] if not use_UFH "HeatPort to force a ground temperature for the ground level's floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}))); -35: Name 'groFloDown' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Down. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groFloDown[5*dis] "Heat port floor of ground floor (towards ground plate)" annotation ( Placement(transformation(extent={{-112,-78},{-92,-58}}), iconTransformation(extent={{-110,-66},{-90,-46}}))); +33: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28})));Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); -36: Name 'groPlateUp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Plate, Up. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groPlateUp[5] "Heat port ground plate towards ground floor" annotation (Placement( transformation(extent={{-112,-100},{-92,-80}}), iconTransformation( extent={{-110,-90},{-90,-70}}))); +34: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[5](redeclare final package Medium = Medium) "Inlet for ventilation" annotation (Placement( transformation(extent={{94,-78},{114,-58}}), iconTransformation(extent={ {94,-70},{108,-56}}))); -37: Missing documentation, Name 'thermalCollectorGroundPlate' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Collector, Ground, Plate. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalCollector thermalCollectorGroundPlate[5](each m= 1) if use_UFH annotation (Placement(transformation(extent={{-32,-98},{-20,-86}}))); +35: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[5](redeclare final package Medium = Medium) "Outlet of Ventilation" annotation (Placement( transformation(extent={{94,-94},{114,-74}}), iconTransformation(extent={ {94,-94},{108,-80}}))); +36: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH.mo -1: Missing documentation, Name 'nZones' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Zones. Affected line: parameter Integer nZones = 11; -2: Missing documentation, Name 'nHeatedRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heated, Rooms. Affected line: parameter Integer nHeatedRooms = 10; +AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL1IwS1Gr1Uf1.mo +1: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -3: Missing documentation. Affected line: parameter Integer dis=10; +2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -4: Missing documentation, Name 'Spacing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Spacing. Affected line: parameter Modelica.Units.SI.Distance Spacing[nHeatedRooms] = fill(0.2, 10); +3: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); -5: Missing documentation. Affected line: parameter Modelica.Units.SI.Diameter dOut[nHeatedRooms] = fill(0.017, 10); +4: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -6: Missing documentation. Affected line: parameter Modelica.Units.SI.Diameter d[nHeatedRooms] = fill(0.018, 10); +5: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); -7: Name 'constAirEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ex. Affected line: Modelica.Blocks.Sources.Constant constAirEx[nZones](k={0.5,0.5,0,0.5,0.5,0.5,0.5,0,0.5,0.5,0}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,6},{-50,26}}))); +6: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -8: Missing documentation, Name 'constWind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind. Affected line: Modelica.Blocks.Sources.Constant constWind(k=0) annotation (Placement(transformation(extent={{-70,36},{-50,56}}))); +7: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constAmb(k=261.15) annotation (Placement(transformation(extent={{-70,70},{-50,90}}))); +8: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -10: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow groundTemp[5](Q_flow= fill(0, 5)) annotation (Placement(transformation(extent={{-54,-96},{-42,-84}}))); +9: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -11: Missing documentation, Name 'heatStarToComb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToComb[nZones] annotation (Placement(transformation( extent={{8,-6},{-8,6}}, rotation=0, origin={-36,-12}))); +10: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -12: Missing documentation, Name 'prescribedAmbTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedAmbTemperature annotation (Placement(transformation(extent={{-40,58},{-28,70}}))); +11: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -13: Missing documentation. Affected line: AixLib.Utilities.Sources.PrescribedSolarRad varRad(n=6) annotation (Placement(transformation(extent={{70,60},{50,80}}))); +12: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -14: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constSun[6](k=fill(0, 6)) annotation (Placement(transformation(extent={{100,70},{80,90}}))); +13: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -15: Missing documentation, Name 'wholeHouseBuildingEnvelope' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: whole, House, Building, Envelope. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=true, redeclare BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, dis=dis, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); +14: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -16: Missing documentation, Name 'prescribedHeatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlowRad[nZones] annotation (Placement(transformation(extent={{-60,-16}, {-48,-4}}))); +15: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -17: Name 'adiabaticRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: adiabatic, Rooms. Affected line: Modelica.Blocks.Sources.Constant adiabaticRadRooms[nZones](k=fill(0, nZones)) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-90,-18}, {-74,-2}}))); +16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, eps_door=eps_door_OD1, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-22},{-50,42}}))); -18: Missing documentation, Name 'fixedHeatFlowAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Attic. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlowAttic[1](Q_flow={0}) annotation (Placement(transformation(extent={{-62,-26}, {-52,-16}}))); +17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={19,57}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); -19: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = AixLib.Media.Water, nZones=10, dis=dis, Q_flow_nominal={638,1078,502,341,783,766,506,196,443,658}, A={wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Children1.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Bath.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Children2.AFloor}, calculateVol=2, wallTypeFloor=fill( BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH(), 10), Ceiling={false,false,false,false,false,true,true,true,true,true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.Ceiling[ 1].Wall.wallType}, TZoneBel_nominal={293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15, 293.15}, Spacing=fill(0.2, 10), pipeMaterial=BaseClasses.PipeMaterials.PERTpipe(), thicknessPipe=fill(0.002, 10), dOut=fill(0.017, 10), withSheathing=false) annotation (Placement(transformation(extent={{-68,-66},{-44,-52}}))); +18: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={58,5}, extent={{-6,-35},{6,35}}, rotation=180))); -20: Missing documentation, Name 'm_flow_specification1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_specification. Affected line: AixLib.Fluid.Sources.MassFlowSource_T m_flow_specification1( redeclare package Medium = AixLib.Media.Water, m_flow=underfloorHeatingSystem.m_flow_nominal, T=underfloorHeatingSystem.T_Vdes, nPorts=1) annotation (Placement(transformation(extent={{-98,-66},{-82,-50}}))); +19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={16,-60}, extent={{-4,-24},{4,24}}, rotation=90))); -21: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.Boundary_pT boundary(redeclare package Medium = AixLib.Media.Water, nPorts=1) annotation (Placement(transformation(extent={{-12,-64},{-24,-52}}))); +20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_low_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); -22: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[sum(underfloorHeatingSystem.ufhRoom.nCircuits)](each k=1) annotation (Placement(transformation( extent={{-6,-6},{6,6}}, rotation=0, origin={-86,-36}))); +21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.groundPlate_upp_half, wall_length=room_length, wall_height=room_width, withWindow=false, outside=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-29,-65}, extent={{-3.00001,-15},{2.99998,15}}, rotation=90))); +22: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow1IwL2IwS1Lf1At1Ro1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +23: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); -2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +25: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={50.5,99}, extent={{-10,-10},{10,10}}, rotation=270))); -4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +26: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling if not use_UFH annotation (Placement(transformation(extent={{80,60},{100,80}}))); -5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +27: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); -6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/UpperFloorBuildingEnvelope.mo +1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); -8: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2.28 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=if withWindow3 then true else false)); +3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2.60 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-60,-12},{-50,46}}))); +4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=1 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -11: Missing documentation, Name 'inner_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inner_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inner_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={-14,58}, extent={{-3.99997,-22},{3.99999,22}}, rotation=270))); +5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2.21 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -12: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,19}, extent={{-3,-15},{3,15}}, rotation=180))); +6: Documentation too short, Name 'length5' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length5. Affected line: parameter Modelica.Units.SI.Length length5=3.3 "l5 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={20,-60}, extent={{-4,-24},{4,24}}, rotation=90))); +7: Documentation too short, Name 'length6' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length6. Affected line: parameter Modelica.Units.SI.Length length6=2.44 "l6 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -14: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=3) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); +8: Documentation too short, Name 'length7' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length7. Affected line: parameter Modelica.Units.SI.Length length7=1.33 "l7 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width_long, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); +9: Documentation too short, Name 'length8' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length8. Affected line: parameter Modelica.Units.SI.Length length8=3.3 "l8 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -16: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-20}, extent={{-2.99998,-16},{2.99998,16}}, rotation=180))); +10: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -17: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, ISOrientation=1) annotation (Placement(transformation( origin={58,59}, extent={{-2.99997,-16},{2.99999,16}}, rotation=270))); +11: Name 'windowarea_63' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_63. Affected line: parameter Modelica.Units.SI.Area windowarea_63=1.73 " Area Window63 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -18: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); +12: Name 'windowarea_72' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_7. Affected line: parameter Modelica.Units.SI.Area windowarea_72=1.73 " Area Window72" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -19: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,0},{100,20}}))); +13: Name 'windowarea_73' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_73. Affected line: parameter Modelica.Units.SI.Area windowarea_73=1.73 " Area Window73 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); +14: Name 'windowarea_92' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_9. Affected line: parameter Modelica.Units.SI.Area windowarea_92=1.73 " Area Window51" annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -21: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +15: Name 'windowarea_102' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_10. Affected line: parameter Modelica.Units.SI.Area windowarea_102=1.73 " Area Window102" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -22: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); +16: Name 'windowarea_103' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_103. Affected line: parameter Modelica.Units.SI.Area windowarea_103=1.73 " Area Window103 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -23: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation(extent={{-16,-104},{4,-84}}))); +17: Name 'Tset_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bedroom. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bedroom=295.15 "Tset_bedroom" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); -24: Missing documentation, Name 'SolarRadiationPort_Roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); +18: Name 'Tset_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children1=295.15 "Tset_children1" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -25: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); +19: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -26: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{-20,80},{0,100}}), iconTransformation(extent={{-20,80},{0,100}}))); +20: Name 'Tset_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bath. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bath=297.15 "Tset_Bath" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +21: Name 'Tset_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children2=295.15 "Tset_children2" annotation (Dialog( group="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomFourWalls.mo -1: Name 'room_length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_length. Affected line: parameter Modelica.Units.SI.Length room_length=6 "length" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +22: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); -2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.7 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +23: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); -3: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=8 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +24: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in RoofS annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,64})));Utilities.Interfaces.SolarRad_in RoofN annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88}))); -4: Name 'Win_Area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Win_, Area. Affected line: parameter Modelica.Units.SI.Area Win_Area=12 "Window area " annotation ( Dialog( group="Windows", descriptionLabel=true)); +25: Missing documentation, Name 'thermFloor_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bedroom if not use_UFH annotation (Placement(transformation(extent={{-66,-120},{-46,-100}}))); -5: Name 'use_shortWaveRadIn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_short, Wave. Affected line: parameter Boolean use_shortWaveRadIn=true "Use bus connector for incoming shortwave radiation" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation")); +26: Missing documentation, Name 'thermFloor_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children1 if not use_UFH annotation (Placement(transformation(extent={{-42,-120},{-22,-100}}))); -6: Name 'use_shortWaveRadOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_short, Wave. Affected line: parameter Boolean use_shortWaveRadOut=true "Use bus connector for outgoing shortwave radiation" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable=use_shortWaveRadIn)); +27: Missing documentation, Name 'thermFloor_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Corridor if not use_UFH annotation (Placement(transformation(extent={{-10,-120},{10,-100}}))); -7: Name 'use_dynamicShortWaveRadMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_dynamic, Short, Wave, Method. Affected line: parameter Boolean use_dynamicShortWaveRadMethod=false "True = dynamic as holistic approach, false = static approach to obtain the same values as provided in tables of the ASHREA" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn)); +28: Missing documentation, Name 'thermFloor_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bath if not use_UFH annotation (Placement(transformation(extent={{20,-120},{40,-100}}))); -8: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: parameter Components.Types.selectorCoefficients absInnerWallSurf=AixLib.ThermalZones.HighOrder.Components.Types.selectorCoefficients.abs06 "Coefficients for interior solar absorptance of wall surface abs={0.6, 0.9, 0.1}" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn and not use_dynamicShortWaveRadMethod)); +29: Missing documentation, Name 'thermFloor_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children2 if not use_UFH annotation (Placement(transformation(extent={{60,-120},{80,-100}}))); -9: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter ThermalZones.HighOrder.Components.Types.CoeffTableEastWestWindow coeffTableSolDistrFractions constrainedby AixLib.ThermalZones.HighOrder.Components.Types.PartialCoeffTable(final abs=absInnerWallSurf) "Record holding the values to reproduce the tables" annotation (choicesAllMatching=true, Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn and not use_dynamicShortWaveRadMethod), Placement(transformation(extent={{78,78},{98,98}}))); +30: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.OFD.Ow2IwL2IwS1Lf1At1Ro1 Bedroom( final denAir=denAir, final cAir=cAir, final use_UFH=use_UFH, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5 + length6 + thickness_IWsimple, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length6, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_62, withWindow3=true, windowarea_RO=windowarea_63, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Bedroom, T0_air=T0_air, nPorts=2, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-82,14},{-42,78}})));Rooms.OFD.Ow2IwL1IwS1Lf1At1Ro1 Children1( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_72, withWindow3=true, windowarea_RO=windowarea_73, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Children1, T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{78,28}, {40,76}})));Rooms.OFD.Ow2IwL1IwS1Lf1At1Ro1 Bath( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, room_length=length8, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_92, withDoor2=false, door_width_OD2=0, door_height_OD2=0, withWindow2=true, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Bath, T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{80,-36}, {42,-84}})));Rooms.OFD.Ow2IwL2IwS1Lf1At1Ro1 Children2( final denAir=denAir, final cAir=cAir, final use_UFH=use_UFH, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length7 + length8 + thickness_IWsimple, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_102, withWindow3=true, windowarea_RO=windowarea_103, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length7, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Children2, T0_air=T0_air, nPorts=2, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,-20},{-44,-84}})));Rooms.OFD.Ow1IwL2IwS1Lf1At1Ro1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, final solar_absorptance_OW=solar_absorptance_OW, room_length=length6 + length7 + thickness_IWsimple, room_lengthb=length7, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, nPorts=2, final use_UFH=use_UFH, redeclare final package Medium = Medium) annotation (Placement(transformation(extent={{78,-28},{ 38,10}})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,40})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,16})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-10})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-36}))); -10: Missing documentation, Name 'wallSouth' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, South. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallSouth( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, wall_length=room_width, solar_absorptance=solar_absorptance_OW, calcMethodOut=calcMethodOut, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, wall_height=room_height, surfaceType=AixLib.DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster()) annotation (Placement(transformation( extent={{-5,-35},{5,35}}, rotation=90, origin={18,-68}))); +31: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-130,10},{-100,40}}))); -11: Missing documentation, Name 'wallWest' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, West. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallWest( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-5,-27},{5,27}}, rotation=0, origin={-83,13}))); +32: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-130,-26},{-100,4}}), iconTransformation(extent={{-130,-26},{-100,4}}))); -12: Missing documentation, Name 'wallEast' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, East. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallEast( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-5,-27},{5,27}}, rotation=180, origin={69,13}))); +33: Missing documentation, Name 'thermCeiling_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bedroom annotation (Placement(transformation(extent={{-98,100},{-82,118}}))); -13: Missing documentation, Name 'wallNorth' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, North. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallNorth( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, wall_length=room_width, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{5.00001,-30},{-5.00001,30}}, rotation=90, origin={18,69}))); +34: Missing documentation, Name 'thermCeiling_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children1 annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); -14: Missing documentation, Name 'ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall ceiling( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_width, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-2,-12},{2,12}}, rotation=270, origin={-42,80}))); +35: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); -15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, outside=false, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_width, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, solar_absorptance=solar_absorptance_OW, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-2.00031,-12},{2.00003,12}}, rotation=90, origin={-42,-68}))); +36: Missing documentation, Name 'thermCeiling_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bath annotation (Placement(transformation(extent={{20,100},{38,118}}))); -16: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort[5] "N,E,S,W,Hor" annotation (Placement(transformation(extent={{-120,46},{-100,66}}), iconTransformation(extent={{-120,46},{-100,66}}))); +37: Missing documentation, Name 'thermCeiling_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children2 annotation (Placement(transformation(extent={{60,100},{78,118}}))); -17: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort annotation (Placement(transformation(extent={{-116,28},{-100,44}}), iconTransformation(extent={{-120,-16},{-100,4}}))); +38: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,-120},{120,-100}}))); -18: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.HeatTransfer.SolarRadInRoom solarRadInRoom( final use_dynamicMethod=use_dynamicShortWaveRadMethod, final nWalls=4, final nWin=nWin, final nFloors=1, final nCei=1, final floor_length=room_length, final floor_width=room_height, final staticCoeffTable=coeffTableSolDistrFractions) if use_shortWaveRadIn and nWin > 0 annotation (Placement(transformation(extent={{-50,26},{-30,46}}))); +39: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28})));Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); -19: Documentation too short, Name 'transShoWaveRadWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: trans, Wave. Affected line: Modelica.Blocks.Interfaces.RealOutput transShoWaveRadWin(final quantity="Power", final unit="W") if use_shortWaveRadOut annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={60,-110}))); +40: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[5](redeclare final package Medium = Medium) "Inlet for ventilation" annotation (Placement( transformation(extent={{94,-78},{114,-58}}), iconTransformation(extent={ {94,-70},{108,-56}}))); -20: Missing documentation, Name 'multiSum' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: multi. Affected line: Modelica.Blocks.Math.MultiSum multiSum(nu=nWin) if use_shortWaveRadOut annotation (Placement(transformation( extent={{2,-2},{-2,2}}, rotation=90, origin={60,-96}))); +41: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[5](redeclare final package Medium = Medium) "Outlet of Ventilation" annotation (Placement( transformation(extent={{94,-94},{114,-74}}), iconTransformation(extent={ {94,-94},{108,-80}}))); -21: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected Utilities.Interfaces.ShortRadSurf shortRadSurf[nWin] if use_shortWaveRadOut annotation (Placement(transformation(extent={{58,-92}, {62,-88}}), iconTransformation(extent={{58,-92}, {62,-88}}))); +42: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); -22: Missing documentation, Name 'usesWindow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: uses, Window. Affected line: protected parameter Boolean usesWindow[4] = {wallEast.withWindow, wallSouth.withWindow, wallWest.withWindow, wallNorth.withWindow}; -23: Missing documentation, Name 'usesWindowInt' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: uses, Window. Affected line: parameter Integer usesWindowInt[4] = {if usesWindow[i] then 1 else 0 for i in 1:size(usesWindow, 1)}; +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Sheathing_Materials/SheathingMaterialDefinition.mo +1: Missing documentation. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda; -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL1IwS1Lf1At1Ro1.mo -1: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingElement.mo +1: Name 'length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length "Length of pipe" annotation (Dialog(group="Panel Heating")); -2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +2: Name 'nPipeLay' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: parameter Integer nPipeLay=if withSheathing then 2 else 1 "Number of pipe layers"; -3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +3: Missing documentation. Affected line: final parameter Modelica.Units.SI.Time tau=VWat*(rho_default*dis)/ m_flow_nominal; -4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +4: Name 'APipeInnSuf' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: final parameter Modelica.Units.SI.Area APipeInnSuf=Modelica.Constants.pi*dInn*length "Surface area inside the pipe"; -5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +5: Name 'hPipeInnTurb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe, Turb. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer hPipeInnTurb=2200 "Coefficient of heat transfer at the inner surface of pipe due to turbulent flow"; -6: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +6: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare final package Medium = Medium, final energyDynamics=energyDynamics, final massDynamics=massDynamics, final p_start=p_start, final T_start=T_start, final X_start=X_start, final C_start=C_start, final C_nominal=C_nominal, final mSenFac=mSenFac, final allowFlowReversal=false, final V=VWat, final nPorts=2, final m_flow_nominal=m_flow_nominal) annotation (Placement(transformation(extent={{-10,0},{10,20}}))); -7: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); +7: Name 'nLayFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer nLayFloor( final A=A, final T_start=fill((T_start), (wallTypeFloor.n)), final wallRec=wallTypeFloor, final energyDynamics=energyDynamicsWalls) "N-Layer floor model" annotation ( Placement(transformation( extent={{-12,-12},{12,12}}, rotation=90, origin={50,70}))); -8: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +8: Name 'heaPorFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a heaPorFloor "Upward heat flow to heated room" annotation (Placement(transformation( extent={{-8,92},{8,108}}), iconTransformation(extent={{-10,32},{10,52}}))); -9: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); +9: Name 'pipeHeaCon' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe. Affected line: AixLib.Utilities.HeatTransfer.CylindricHeatConduction pipeHeaCon[nPipeLay]( final d_out=if withSheathing then {dOut, dOut + thicknessSheathing} else {dOut}, final lambda=if withSheathing then {pipeMaterial.lambda,sheathingMaterial.lambda} else {pipeMaterial.lambda}, final d_in=if withSheathing then {dInn, dOut} else {dInn}, each final nParallel=1, each final length=length) "Cylindric heat conduction through pipe" annotation ( Placement(transformation( extent={{10,-10},{-10,10}}, rotation=270, origin={-30,60}))); -10: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +10: Missing documentation, Name 'heatConvPipeInside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Conv, Pipe, Inside. Affected line: AixLib.Utilities.HeatTransfer.HeatConv heatConvPipeInside(hCon=hPipeInnTurb, A=APipeInnSuf) annotation (Placement(transformation( extent={{-12,-12},{12,12}}, rotation=270, origin={-30,30}))); -11: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -12: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL1IwS1Lf1At1Ro1.mo +1: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -14: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -15: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); +4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-62,-20},{-52,38}}))); +5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), ISOrientation=1, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={-29,59}, extent={{-5.00001,-29},{5.00001,29}}, rotation=270))); +6: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); -18: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,4.00001}, extent={{-4.99999,-30},{5,30}}, rotation=180))); +7: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={32,-59}, extent={{-4.99998,-28},{4.99998,28}}, rotation=90))); +8: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); -20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=3) annotation (Placement(transformation( origin={22,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); +9: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width_long, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); +10: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -22: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO) annotation (Placement(transformation( origin={55,59}, extent={{-2.99995,-17},{2.99997,17}}, rotation=270))); +11: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -23: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); +12: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); +13: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -25: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); +14: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); -26: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +15: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-62,-20},{-52,38}}))); -27: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); +16: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.vertical_wall, U_door=U_door_OD2, eps_door=eps_door_OD2, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={-29,59}, extent={{-5.00001,-29},{5.00001,29}}, rotation=270))); -28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,60},{100,80}}))); +17: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,4.00001}, extent={{-4.99999,-30},{5,30}}, rotation=180))); -29: Missing documentation, Name 'SolarRadiationPort_Roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); +18: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={32,-59}, extent={{-4.99998,-28},{4.99998,28}}, rotation=90))); -30: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor[dis] annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); +19: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={22,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); +20: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo -1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); +21: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={55,59}, extent={{-2.99995,-17},{2.99997,17}}, rotation=270))); -2: Name 'AirExchangeCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor. Affected line: parameter Real AirExchangeCorridor=2 "Air exchange corridors in 1/h " annotation (Dialog(group="Air Exchange Corridors", descriptionLabel=true)); +22: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); -3: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.1 "Solar absoptance roof " annotation (Dialog(tab="Outer walls", group="Solar absorptance", descriptionLabel=true)); +23: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); -4: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors=2.5 "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); +24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -5: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); +25: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); -6: Name 'TDynVentHobby_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Hobby_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentHobby_set=295.15 "Hobby set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +26: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,60},{100,80}}))); -7: Name 'TDynVentCorridorGF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, G, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorGF_set=291.15 "Corridor (GF) set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); -8: Name 'TDynVentWCStorage_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, W, Storage_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentWCStorage_set=291.15 "WC / Storage room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +28: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor if not use_UFH annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); -9: Name 'TDynVentKitchen_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Kitchen_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentKitchen_set=295.15 "Kitchen set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -10: Name 'TDynVentBedroom_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bedroom_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBedroom_set=295.15 "Bedroom set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomParams.mo +1: Name 'use_UFH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: F. Affected line: parameter Boolean use_UFH = false "If underfloor heating, conductive wall layers in floor and ceiling are disabled" annotation(Dialog(group = "Structure of wall layers")); -11: Name 'TDynVentChildren1_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children1_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren1_set=295.15 "Children 1 room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +2: Name 'wallTypes' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Types. Affected line: replaceable parameter AixLib.DataBase.Walls.Collections.BaseDataMultiWalls wallTypes constrainedby AixLib.DataBase.Walls.Collections.BaseDataMultiWalls "Types of walls (contains multiple records)" annotation(Dialog(group = "Structure of wall layers"), choicesAllMatching = true, Placement(transformation(extent={{-8,82},{8,98}}))); -12: Name 'TDynVentCorridorUF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorUF_set=291.15 "Corridor (UF) set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +3: Name 'energyDynamicsWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: energy, Dynamics, Walls. Affected line: parameter Modelica.Fluid.Types.Dynamics energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.DynamicFreeInitial "Type of energy balance for wall capacities: dynamic (3 initialization options) or steady state" annotation(Evaluate=true, Dialog(tab="Dynamics")); -13: Name 'TDynVentBath_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bath_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBath_set=297.15 "Bathroom set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +4: Documentation too short, Name 'T0_air' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T0_air. Affected line: parameter Modelica.Units.SI.Temperature T0_air=295.11 "Air" annotation (Dialog(tab="Initialization", group="Air volume of room")); -14: Name 'TDynVentChildren2_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children2_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren2_set=295.15 "Children 2 room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +5: Name 'TWalls_start' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Walls. Affected line: parameter Modelica.Units.SI.Temperature TWalls_start= Modelica.Units.Conversions.from_degC(16) "Initial temperature of all walls" annotation (Dialog(tab="Initialization", group="Walls")); -15: Name 'TDynVentAttic_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Attic_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentAttic_set=288.15 "Attic set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); +6: Name 'radLongCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Long, Calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer radLongCalcMethod=AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx "Calculation method for longwave radiation heat transfer" annotation ( Evaluate=true, Dialog(tab="Inner walls", group="Longwave radiation", compact=true)); -16: Name 'useVentAirPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Port. Affected line: parameter Boolean useVentAirPort = false "Use air port for ventialtion" annotation (Dialog(tab= "Dynamic ventilation")); +7: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization of longwave radiation" annotation (Dialog( tab="Inner walls", group="Longwave radiation", enable=radLongCalcMethod == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_constant_T_ref)); -17: Missing documentation, Name 'groundFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.GroundFloorBuildingEnvelope groundFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, redeclare package Medium = Medium, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final Tset_Livingroom=TDynVentLivingroom_set, final Tset_Hobby=TDynVentHobby_set, final Tset_Corridor=TDynVentCorridorGF_set, final Tset_WC=TDynVentWCStorage_set, final Tset_Kitchen=TDynVentKitchen_set, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-20,-74},{20,-26}}))); +8: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.WindowsDoors.Simple.OWBaseDataDefinition_Simple Type_Win "Window parametrization" annotation (Dialog(tab="Outer walls", group="Windows"), choicesAllMatching = true); -18: Missing documentation, Name 'upperFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: upper, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.UpperFloorBuildingEnvelope upperFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final withDynamicVentilation=withDynamicVentilation, redeclare package Medium = Medium, final solar_absorptance_RO=solar_absorptance_RO, final Tset_Bedroom=TDynVentBedroom_set, final Tset_Children1=TDynVentChildren1_set, final Tset_Corridor=TDynVentCorridorUF_set, final Tset_Bath=TDynVentBath_set, final Tset_Children2=TDynVentChildren2_set, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-26,-12}, {20,34}}))); +9: Name 'CorrSolarGainWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Corr, Solar. Affected line: replaceable model CorrSolarGainWin = AixLib.ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.PartialCorG constrainedby AixLib.ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.PartialCorG "Correction model for solar irradiance as transmitted radiation" annotation (choicesAllMatching=true, Dialog(tab="Outer walls", group="Windows", enable = withWindow and outside)); -19: Missing documentation, Name 'attic_2Ro_5Rooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: attic_, Ro_5, Rooms. Affected line: AixLib.ThermalZones.HighOrder.Rooms.OFD.Attic_Ro2Lf5 attic_2Ro_5Rooms( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=TDynVentAttic_set, final solar_absorptance_RO=solar_absorptance_RO, length=10.64, width=4.75, roof_width1=3.36, roof_width2=3.36, room1_length=5.875, room2_length=3.215, room3_length=3.92, room4_length=3.215, room5_length=4.62, room1_width=2.28, room2_width=2.28, room3_width=2.28, room4_width=2.28, room5_width=2.28, nPorts=2, alfa=1.5707963267949, replaceable package Medium = Medium) annotation (Placement(transformation(extent={{-22,44},{22,82}}))); +10: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.Surfaces.RoughnessForHT.PolynomialCoefficients_ASHRAEHandbook surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster() "Surface type of outside wall" annotation (Dialog(tab="Outer walls", group="Heat convection", enable=(calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals))); -20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement( transformation(extent={{-128,66},{-100,94}}),iconTransformation(extent={{-120,60},{-100,80}}))); +11: Name 'ratioSunblind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Sunblind. Affected line: parameter Real ratioSunblind(min=0.0, max=1.0) = 0.8 "Sunblind factor. 1 means total blocking of irradiation, 0 no sunblind" annotation(Dialog(tab="Outer walls", group = "Sunblind", enable=use_sunblind)); -21: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-128,42},{-100,70}}), iconTransformation(extent={{-120,40},{-100,60}}))); +12: Name 'solIrrThreshold' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold. Affected line: parameter Modelica.Units.SI.Irradiance solIrrThreshold(min=0.0) = 350 "Threshold for global solar irradiation on this surface to enable sunblinding (see also TOutAirLimit)" annotation (Dialog( tab="Outer walls", group="Sunblind", enable=use_sunblind)); -22: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofS annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,64}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,64})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofN annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,38}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,38})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,12}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,12})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-14}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-14})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-38}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-38}))); +13: Name 'TOutAirLimit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Limit. Affected line: parameter Modelica.Units.SI.Temperature TOutAirLimit=293.15 "Temperature at which sunblind closes (see also solIrrThreshold)" annotation (Dialog( tab="Outer walls", group="Sunblind", enable=use_sunblind)); -23: Missing documentation, Name 'varAirExchange' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange. Affected line: AixLib.ThermalZones.HighOrder.Components.DryAir.VarAirExchange varAirExchange( final V=0.5*(upperFloor_Building.Corridor.airload.V + groundFloor_Building.Corridor.airload.V), final c=cAir, final rho=denAir) annotation (Placement( transformation( extent={{-5,5},{5,-5}}, rotation=270, origin={39,-21}))); +14: Name 'e' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: e. Affected line: parameter Real e=0.03 "Coefficient of windshield" annotation (Dialog(tab="Infiltration acc. to EN 12831 (airtightness)", enable=use_infiltEN12831)); -24: Missing documentation, Name 'AirExchangeCorridor_Source' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor_, Source. Affected line: Modelica.Blocks.Sources.Constant AirExchangeCorridor_Source(final k=AirExchangeCorridor) annotation (Placement(transformation(extent={{56,-16},{50,-10}}))); +15: Name 'HeatingLimit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heating, Limit. Affected line: parameter Modelica.Units.SI.Temperature HeatingLimit=288.15 "Outside temperature at which the heating activates" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); -25: Name 'heatingToRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heating, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb heatingToRooms[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-112,-30},{-92,-10}}), iconTransformation(extent={{-110,-38},{-90,-18}}))); +16: Name 'Max_VR' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Max_. Affected line: parameter Real Max_VR=10 "Maximal ventilation rate" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); -26: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] if not use_UFH "HeatPorts to force ground temperature(s) for the ground floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}), iconTransformation(extent={{-10,-110},{10,-90}}))); +17: Name 'Diff_toTempset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Diff_to, Tempset. Affected line: parameter Modelica.Units.SI.TemperatureDifference Diff_toTempset=2 "Difference to set temperature" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); -27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Components.Walls.BaseClasses.SimpleNLayer groPlateLowPart[5]( final A={groundFloor_Building.Livingroom.floor.Wall.A,groundFloor_Building.Hobby.floor.Wall.A, groundFloor_Building.Corridor.floor.Wall.A,groundFloor_Building.WC_Storage.floor.Wall.A, groundFloor_Building.Kitchen.floor.Wall.A}, each final T_start=fill(TWalls_start, wallTypes.groundPlate_low_half.n), each final wallRec=wallTypes.groundPlate_low_half, each final energyDynamics=energyDynamicsWalls) if not (use_UFH) annotation (Placement(transformation( extent={{-4,-18},{4,18}}, rotation=-90, origin={0,-86})));Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombAttic annotation (Placement(transformation( extent={{6,-5},{-6,5}}, rotation=180, origin={-36,51}))); +18: Documentation too short, Name 'Tset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset. Affected line: parameter Modelica.Units.SI.Temperature Tset=295.15 "Tset" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); -28: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[11](redeclare final package Medium = Medium) if useVentAirPort "Inlet for ventilation" annotation ( Placement(transformation(extent={{90,-78},{110,-58}}), iconTransformation( extent={{94,-70},{108,-56}}))); -29: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[11](redeclare final package Medium = Medium) if useVentAirPort "Outlet of Ventilation" annotation (Placement( transformation(extent={{90,-98},{110,-78}}), iconTransformation(extent={ {96,-92},{110,-78}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/RadConvToSingle.mo +1: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portCon annotation (Placement(transformation(extent={{-110,50},{-90,70}}))); -30: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-112,90},{-92,110}}))); +2: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portRad annotation (Placement(transformation(extent={{-110,-72},{ -90,-52}}))); AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingSystem.mo @@ -963,518 +951,540 @@ AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingSyste 32: Name 'rho_default' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: rho_default. Affected line: parameter Modelica.Units.SI.Density rho_default=Medium.density(sta_default) "Density, used to compute fluid volume"; -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/RadiativeConvectiveHeatTransfer.mo -1: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization" annotation (Dialog(enable=radCalcMethod == 4)); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL1IwS1Gr1Uf1.mo +1: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -2: Name 'radCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Calc, Method. Affected line: parameter Integer radCalcMethod=1 "Calculation method for radiation heat transfer" annotation ( Evaluate=true, Dialog(group = "Radiation exchange equation", compact=true), choices( choice=1 "No approx", choice=2 "Linear approx at wall temp", choice=3 "Linear approx at rad temp", choice=4 "Linear approx at constant T_ref", radioButtons=true)); +2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -3: Name 'calcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calc, Method. Affected line: parameter Integer calcMethod=2 "Calculation method for convective heat transfer coefficient" annotation ( Dialog(descriptionLabel=true), choices( choice=1 "EN ISO 6946 Appendix A >>Flat Surfaces<<", choice=2 "By Bernd Glueck", choice=3 "Custom hCon (constant)", choice=4 "ASHRAE140-2017", radioButtons=true), Evaluate=true); +3: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); -4: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.HeatTransfer.HeatToRad twoStar_RadEx( final eps=eps, final T_ref=T_ref, final use_A_in=false, final A=A, final radCalcMethod=radCalcMethod) annotation (Placement(transformation(extent={{-10,30},{10,50}})));Utilities.HeatTransfer.HeatConvInside heatConv( final dT_small=dT_small, final A=A, final hCon_const=hCon_const, final calcMethod=calcMethod, final surfaceOrientation=surfaceOrientation) annotation (Placement(transformation( origin={-2,-40}, extent={{-12,-12},{12,12}}, rotation=180))); +4: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); -5: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a annotation (Placement(transformation(extent={{-110,-10},{-90, 10}}))); +5: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +6: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); -AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow1IwL2IwS1Lf1At1Ro1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +7: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +8: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +9: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +10: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +11: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +12: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); +13: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -8: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=if withWindow3 then true else false)); +14: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -9: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-12},{-50,46}}))); +15: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -10: Missing documentation, Name 'inner_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inner_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inner_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={-14,58}, extent={{-3.99997,-22},{3.99999,22}}, rotation=270))); +16: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -11: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,19}, extent={{-3,-15},{3,15}}, rotation=180))); +17: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-60,-22},{-50,42}}))); -12: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={20,-60}, extent={{-4,-24},{4,24}}, rotation=90))); +18: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={19,57}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); -13: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); +19: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={58,5}, extent={{-6,-35},{6,35}}, rotation=180))); -14: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); +20: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={16,-60}, extent={{-4,-24},{4,24}}, rotation=90))); -15: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,-20}, extent={{-2.99998,-16},{2.99998,16}}, rotation=180))); +21: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); -16: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.vertical_wall, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={58,59}, extent={{-2.99997,-16},{2.99999,16}}, rotation=270))); +22: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each outside=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-29,-65}, extent={{-3.00001,-15},{2.99998,15}}, rotation=90))); -17: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); +23: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); -18: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,0},{100,20}}))); +24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); -19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); +25: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -20: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +26: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); -21: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); +27: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={50.5,99}, extent={{-10,-10},{10,10}}, rotation=270))); -22: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor if not use_UFH annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); +28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); -23: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); +29: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); -24: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); -25: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{-20,80},{0,100}}), iconTransformation(extent={{-20,80},{0,100}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH_WODis.mo +1: Missing documentation, Name 'nZones' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Zones. Affected line: parameter Integer nZones = 11; +2: Missing documentation, Name 'nHeatedRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heated, Rooms. Affected line: parameter Integer nHeatedRooms = 10; -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/Tables/CombiTable2DParameter.mo -1: Missing documentation, Name 'tableID;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: input Modelica.Blocks.Types.ExternalCombiTable2D tableID; +3: Missing documentation. Affected line: parameter Integer dis=1; -2: Missing documentation, Name 'u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u1. Affected line: input Real u1; +4: Missing documentation, Name 'Spacing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Spacing. Affected line: parameter Modelica.Units.SI.Distance Spacing[nHeatedRooms] = fill(0.2, 10); -3: Missing documentation, Name 'u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u2. Affected line: input Real u2; +5: Missing documentation. Affected line: parameter Modelica.Units.SI.Diameter dOut[nHeatedRooms] = fill(0.017, 10); -4: Name 'tableAvailable' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Available. Affected line: input Real tableAvailable "Dummy input to ensure correct sorting of function calls"; +6: Missing documentation. Affected line: parameter Modelica.Units.SI.Diameter d[nHeatedRooms] = fill(0.018, 10); -5: Missing documentation. Affected line: output Real y; +7: Name 'constAirEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ex. Affected line: Modelica.Blocks.Sources.Constant constAirEx[nZones](k={0.5,0.5,0,0.5,0.5,0.5,0.5,0,0.5,0.5,0}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,6},{-50,26}}))); -6: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: external"C" y = ModelicaStandardTables_CombiTable2D_getValue(tableID, u1, u2) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});annotation (derivative(noDerivative=tableAvailable) = getDerTableValue);end getTableValue; +8: Missing documentation, Name 'constWind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind. Affected line: Modelica.Blocks.Sources.Constant constWind(k=0) annotation (Placement(transformation(extent={{-70,36},{-50,56}}))); -7: Name 'getDerTableValue' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Table, Value. Affected line: function getDerTableValue "Derivative of interpolated 2-dim. table defined by matrix" extends Modelica.Icons.Function; +9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constAmb(k=261.15) annotation (Placement(transformation(extent={{-70,70},{-50,90}}))); -8: Missing documentation, Name 'der_u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u1. Affected line: input Real der_u1; +10: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow groundTemp[5](Q_flow= fill(0, 5)) annotation (Placement(transformation(extent={{-6,-6},{6,6}}, rotation=180, origin={64,-70}))); -9: Missing documentation, Name 'der_u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u2. Affected line: input Real der_u2; +11: Missing documentation, Name 'heatStarToComb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToComb[nZones] annotation (Placement(transformation( extent={{8,-6},{-8,6}}, rotation=0, origin={-36,-12}))); -10: Missing documentation, Name 'der_y;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_y. Affected line: output Real der_y; +12: Missing documentation, Name 'prescribedAmbTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedAmbTemperature annotation (Placement(transformation(extent={{-40,58},{-28,70}}))); -11: Documentation too short, Name 'external' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: external. Affected line: external"C" der_y = ModelicaStandardTables_CombiTable2D_getDerValue(tableID, u1, u2, der_u1, der_u2) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});end getDerTableValue; +13: Missing documentation. Affected line: AixLib.Utilities.Sources.PrescribedSolarRad varRad(n=6) annotation (Placement(transformation(extent={{70,60},{50,80}}))); + +14: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constSun[6](k=fill(0, 6)) annotation (Placement(transformation(extent={{100,70},{80,90}}))); + +15: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=true, redeclare BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); + +16: Missing documentation, Name 'prescribedHeatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlowRad[nZones] annotation (Placement(transformation(extent={{-60,-16}, {-48,-4}}))); + +17: Name 'adiabaticRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: adiabatic, Rooms. Affected line: Modelica.Blocks.Sources.Constant adiabaticRadRooms[nZones](k=fill(0, nZones)) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-90,-18}, {-74,-2}}))); + +18: Missing documentation, Name 'fixedHeatFlowAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Attic. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlowAttic[1](Q_flow={0}) annotation (Placement(transformation(extent={{-62,-26}, {-52,-16}}))); + +19: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = AixLib.Media.Water, m_flow_nominal=0.1, thicknessSheathing=0.005, sheathingMaterial(lambda=0.15), nZones=10, dis=dis, Q_flow_nominal={638,1078,502,341,783,766,506,196,443,658}, A={ wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.room_width, wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Children1.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Children1.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Bath.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Bath.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Children2.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Children2.room_width_long}, calculateVol=2, use_vmax=1, wallTypeFloor=fill( BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH(), 10), Ceiling={false,false,false,false,false,true,true,true,true,true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.wallTypes.IW_hori_low_half}, TZoneBel_nominal={293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15, 293.15,293.15}, Spacing=fill(0.2, 10), pipeMaterial=BaseClasses.PipeMaterials.PERTpipe(), thicknessPipe=fill(0.002, 10), dOut=fill(0.017, 10), withSheathing=true, ufhRoom( thicknessSheathing=0.005, TSup_nominal(displayUnit="K") = 308.15, TRet_nominal( displayUnit="K") = 303.15, circuits(thicknessSheathing=0.005, length=80), EN_1264(sheathingMaterial={ AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition( lambda=0.15)}, pipeMaterial={ AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22), AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition( lambda=0.22)}))) annotation (Placement(transformation(extent={{-68,-66},{-50,-50}}))); + +20: Missing documentation, Name 'm_flow_specification1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_specification. Affected line: AixLib.Fluid.Sources.MassFlowSource_T m_flow_specification1( redeclare package Medium = AixLib.Media.Water, m_flow=underfloorHeatingSystem.m_flow_nominal, T=underfloorHeatingSystem.T_Vdes, nPorts=1) annotation (Placement(transformation(extent={{-98,-66},{-82,-50}}))); + +21: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.Boundary_pT boundary(redeclare package Medium = AixLib.Media.Water, nPorts=1) annotation (Placement(transformation(extent={{-12,-64},{-24,-52}}))); + +22: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[underfloorHeatingSystem.nZones](each k =1) annotation (Placement(transformation( extent={{-6,-6},{6,6}}, rotation=0, origin={-86,-36}))); + + +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL1IwS1Lf1At1Ro1.mo +1: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -12: Name 'table' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: parameter Real table[:, :] "Table matrix (grid u1 = first column, grid u2 = first row; e.g., table=[0,0;0,1])" annotation (Dialog(group="Table data definition")); +2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Name 'tableID' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: final parameter Modelica.Blocks.Types.ExternalCombiTable2D tableID= Modelica.Blocks.Types.ExternalCombiTable2D( "NoName", "NoName", table, Modelica.Blocks.Types.Smoothness.LinearSegments) "External table object"; +3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -14: Missing documentation, Name 'u1;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u1. Affected line: parameter Real u1; +4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -15: Missing documentation, Name 'u2;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: u2. Affected line: parameter Real u2; +5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -16: Missing documentation. Affected line: final parameter Real y = getTableValue(tableID, u1, u2, 1.0); +6: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +7: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); -AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow1IwL2IwS1Gr1Uf1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +8: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +9: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); -3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +10: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -4: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); +11: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -5: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +12: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -6: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +13: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -7: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +14: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -8: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +15: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); -9: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-62,-20},{-52,38}}))); -10: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-14},{-50,42}}))); +17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), ISOrientation=1, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={-29,59}, extent={{-5.00001,-29},{5.00001,29}}, rotation=270))); -11: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={23,59}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); +18: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,4.00001}, extent={{-4.99999,-30},{5,30}}, rotation=180))); -12: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,23}, extent={{-3,-15},{3,15}}, rotation=180))); +19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={32,-59}, extent={{-4.99998,-28},{4.99998,28}}, rotation=90))); -13: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={25,-59}, extent={{-5.00002,-29},{5.00001,29}}, rotation=90))); +20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=3) annotation (Placement(transformation( origin={22,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); -14: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_low_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-31,60}, extent={{2,-9},{-2,9}}, rotation=90))); +21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width_long, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); -15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.groundPlate_upp_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); +22: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO) annotation (Placement(transformation( origin={55,59}, extent={{-2.99995,-17},{2.99997,17}}, rotation=270))); -16: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); +23: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); -17: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{34,-104},{54,-84}}))); +24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); -18: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,20},{100,40}}))); +25: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -19: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement( transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation( extent={{-109.5,-70},{-89.5,-50}}))); +26: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); -20: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,50},{-89.5,70}}))); +27: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); -21: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling if not use_UFH annotation (Placement(transformation(extent={{80,60},{100,80}}))); +28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,60},{100,80}}))); -22: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); +29: Missing documentation, Name 'SolarRadiationPort_Roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); -23: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); +30: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor[dis] annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); -24: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{20,80},{40,100}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PressureLoss/GetPressureLossOfUFHDistributor.mo +1: Name 'preDrop' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Drop. Affected line: output Modelica.Units.SI.PressureDifference preDrop "Pressure drop for the given input"; -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/SimpleRoom/OneRoomSimple_qu.mo -1: Missing documentation, Name 'MediumAir' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: package MediumAir = AixLib.Media.Air; +2: Name 'table_internal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Real table_internal "Table with offset for the different number of heating circuit outlets"; -2: Missing documentation, Name 'MediumWater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium, Water. Affected line: package MediumWater = AixLib.Media.Water; +3: Name 'offset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: offset. Affected line: Real offset "Output of the table"; -3: Missing documentation, Name 'area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: area. Affected line: parameter Modelica.Units.SI.Area area=20; -4: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{-10,44},{10,64}}))); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo +1: Missing documentation, Name 'nRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Rooms. Affected line: parameter Integer nRooms = 11; -5: Missing documentation, Name 'fixedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow(Q_flow=-1000) annotation (Placement(transformation(extent={{-40,74},{-20,94}}))); +2: Missing documentation, Name 'nHeatedRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heated, Rooms. Affected line: parameter Integer nHeatedRooms = 10; -6: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = MediumWater, nZones=1, dis=dis, Q_flow_nominal=-1.*{fixedHeatFlow.Q_flow}, A={area}, wallTypeFloor={ UnderfloorHeating.BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH()}, Ceiling={true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.CEpartition_EnEV2009_SM_loHalf_UFH()}, Spacing={0.35}, thicknessPipe={0.002}, dOut={0.017}, withSheathing=false) annotation (Placement(transformation(extent={{-32,-32},{18,-2}}))); +3: Missing documentation. Affected line: parameter Integer dis = wholeHouseBuildingEnvelope.dis; -7: Missing documentation, Name 'thermalConductor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor[dis](each G= area/dis*10.8) annotation (Placement(transformation(extent={{-4,20},{-24,40}}))); +4: Name 'constRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Rooms. Affected line: Modelica.Blocks.Sources.Constant constRooms[nHeatedRooms](k={293.15,293.15,293.15, 293.15,293.15,293.15,293.15,293.15,293.15,293.15}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,-62},{-50,-42}}))); -8: Missing documentation, Name 'fixedHeatFlow1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow1(Q_flow=-232) annotation (Placement(transformation(extent={{58,-100},{38,-80}}))); +5: Name 'constAirEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ex. Affected line: Modelica.Blocks.Sources.Constant constAirEx[nRooms](k={0.5,0.5,0,0.5,0.5,0.5,0.5,0,0.5,0.5,0}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,6},{-50,26}}))); -9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[1](each k=1) annotation (Placement(transformation(extent={{-100,6},{-86,20}}))); +6: Missing documentation, Name 'constWind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind. Affected line: Modelica.Blocks.Sources.Constant constWind(k=0) annotation (Placement(transformation(extent={{-70,36},{-50,56}}))); -10: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.MassFlowSource_T boundary( redeclare package Medium = MediumWater, use_m_flow_in=true, use_T_in=true, nPorts=1) annotation (Placement(transformation(extent={{-98,-26},{-78,-6}}))); +7: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constAmb(k=261.15) annotation (Placement(transformation(extent={{-70,70},{-50,90}}))); -11: Missing documentation. Affected line: AixLib.Fluid.Sources.Boundary_pT bou(redeclare package Medium = MediumWater, nPorts=1) annotation (Placement(transformation(extent={{74,-28},{54,-8}}))); +8: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature groundTemp[5](T=fill( 273.15 + 8.5, 5)) annotation (Placement(transformation(extent={{-54,-96},{-42,-84}}))); -12: Missing documentation, Name 'thermalConductor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor1 [dis](each G= area/dis*5.8824) annotation (Placement(transformation(extent={{18,-76},{-2,-56}}))); +9: Missing documentation, Name 'prescribedTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedTemperature[nHeatedRooms] annotation (Placement(transformation(extent={{-36,-58},{-24,-46}}))); -13: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol1( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{36,-76},{56,-56}}))); +10: Missing documentation, Name 'heatStarToComb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToComb[nRooms] annotation (Placement(transformation( extent={{8,-6},{-8,6}}, rotation=0, origin={-36,-20}))); +11: Missing documentation, Name 'prescribedAmbTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedAmbTemperature annotation (Placement(transformation(extent={{-40,58},{-28,70}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PressureLoss/GetPressureLossOfUFHDistributor.mo -1: Name 'preDrop' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Drop. Affected line: output Modelica.Units.SI.PressureDifference preDrop "Pressure drop for the given input"; +12: Missing documentation. Affected line: AixLib.Utilities.Sources.PrescribedSolarRad varRad(n=6) annotation (Placement(transformation(extent={{70,60},{50,80}}))); -2: Name 'table_internal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: Real table_internal "Table with offset for the different number of heating circuit outlets"; +13: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constSun[6](k=fill(0, 6)) annotation (Placement(transformation(extent={{100,70},{80,90}}))); -3: Name 'offset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: offset. Affected line: Real offset "Output of the table"; +14: Missing documentation, Name 'sumHeatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat, Loads. Affected line: Modelica.Blocks.Sources.RealExpression sumHeatLoads(y=-sum(prescribedTemperature[:].port.Q_flow)) annotation (Placement(transformation(extent={{42,-72},{62,-52}}))); +15: Missing documentation, Name 'heatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Loads. Affected line: Modelica.Blocks.Sources.RealExpression heatLoads[nHeatedRooms](y=-(prescribedTemperature[:].port.Q_flow)) annotation (Placement(transformation(extent={{42,-92},{62,-72}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PipeMaterials/PipeMaterialDefinition.mo -1: Missing documentation. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda; +16: Missing documentation, Name 'totalHeatLoad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: total, Heat, Load. Affected line: Modelica.Blocks.Interfaces.RealOutput totalHeatLoad annotation (Placement(transformation(extent={{88,-72},{108,-52}}))); +17: Missing documentation, Name 'roomHeatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat, Loads. Affected line: Modelica.Blocks.Interfaces.RealOutput roomHeatLoads[nHeatedRooms] annotation (Placement(transformation(extent={{88,-92},{108,-72}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingRoom.mo -1: Name 'nCircuits' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Circuits. Affected line: final parameter Integer nCircuits(min=1) = integer(ceil(length/lengthMax)) "Number of circuits in one zone"; +18: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=false, redeclare Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, initDynamicsAir=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, dis=1, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); -2: Name 'lengthMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length lengthMax=120 "Maximum Length for one Circuit" annotation (Dialog(group="Panel Heating")); +19: Missing documentation, Name 'prescribedHeatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlowRad[nRooms] annotation (Placement(transformation(extent={{-60,-24},{-48,-12}}))); -3: Name 'q_flow_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q. Affected line: final parameter Modelica.Units.SI.HeatFlux q_flow_nominal=Q_flow_nominal/A "Area specific heat flow rate "; +20: Name 'adiabaticRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: adiabatic, Rooms. Affected line: Modelica.Blocks.Sources.Constant adiabaticRadRooms[nRooms](k=fill(0, nRooms)) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-90,-26},{-74,-10}}))); -4: Name 'dpPipe_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Pipe. Affected line: parameter Modelica.Units.SI.PressureDifference dpPipe_nominal=100*length "Nominal pressure drop in every heating circuit" annotation (Dialog(group="Pressure Drop")); +21: Missing documentation, Name 'fixedHeatFlowAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Attic. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlowAttic[1](Q_flow= {0}) annotation (Placement(transformation(extent={{-62,-34},{-52, -24}}))); -5: Name 'dpValve_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Valve. Affected line: parameter Modelica.Units.SI.PressureDifference dpValve_nominal=0 "Pressure Difference set in regulating valve for pressure equalization" annotation (Dialog(group= "Pressure Drop")); -6: Name 'dpFixed_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Fixed. Affected line: parameter Modelica.Units.SI.PressureDifference dpFixed_nominal=0 "Additional pressure drop for every heating circuit, e.g. for distributor" annotation (Dialog(group="Pressure Drop")); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/UpperFloorBuildingEnvelope.mo +1: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2.28 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -7: Name 'q_Gmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Gmax. Affected line: final parameter Modelica.Units.SI.HeatFlux q_Gmax=8.92*(TSurMax - TZone_nominal)^(1.1) "Maximum possible heat flux with given surface temperature and room temperature"; +2: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2.60 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -8: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling "false if ground plate is under panel heating" annotation (Dialog(group="Room Specifications"), choices(checkBox=true)); +3: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=1 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Name 'spacing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: spacing. Affected line: parameter Modelica.Units.SI.Distance spacing "Spacing between tubes" annotation (Dialog(group="Panel Heating")); +4: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2.21 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Name 'length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: final parameter Modelica.Units.SI.Length length=A/spacing "Possible pipe length for given panel heating area"; +5: Documentation too short, Name 'length5' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length5. Affected line: parameter Modelica.Units.SI.Length length5=3.3 "l5 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -11: Name 'InsulationThickness' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Insulation, Thickness. Affected line: final parameter Modelica.Units.SI.Thickness InsulationThickness= wallTypeCeiling.d[1] "Thickness of thermal insulation"; +6: Documentation too short, Name 'length6' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length6. Affected line: parameter Modelica.Units.SI.Length length6=2.44 "l6 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -12: Name 'lambda_ins' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_ins. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_ins= wallTypeCeiling.lambda[1] "Thermal conductivity of thermal insulation"; +7: Documentation too short, Name 'length7' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length7. Affected line: parameter Modelica.Units.SI.Length length7=1.33 "l7 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Name 'R_lambdaIns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaIns= InsulationThickness/lambda_ins "Thermal resistance of thermal insulation"; +8: Documentation too short, Name 'length8' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length8. Affected line: parameter Modelica.Units.SI.Length length8=3.3 "l8 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -14: Name 'CoverThickness' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Cover, Thickness. Affected line: final parameter Modelica.Units.SI.Thickness CoverThickness=wallTypeFloor.d[1] "thickness of cover above pipe"; +9: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -15: Name 'lambda_u' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_u=wallTypeFloor.lambda[1] "Thermal conductivity of wall layers above panel heating without flooring (coverage)"; +10: Name 'windowarea_63' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_63. Affected line: parameter Modelica.Units.SI.Area windowarea_63=1.73 " Area Window63 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -16: Name 'lambda_E' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_E=lambda_u "Thermal conductivity of cover"; +11: Name 'windowarea_72' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_7. Affected line: parameter Modelica.Units.SI.Area windowarea_72=1.73 " Area Window72" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -17: Name 'R_lambdaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaCeiling=if Ceiling then wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] else (wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] + wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] + wallTypeCeiling.d[4]/wallTypeCeiling.lambda[4]) "Thermal resistance of ceiling"; +12: Name 'windowarea_73' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_73. Affected line: parameter Modelica.Units.SI.Area windowarea_73=1.73 " Area Window73 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -18: Name 'R_lambdaPlaster' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Plaster. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaPlaster=if Ceiling then wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] else 0 "Thermal resistance of plaster"; +13: Name 'windowarea_92' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_9. Affected line: parameter Modelica.Units.SI.Area windowarea_92=1.73 " Area Window51" annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -19: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling = 5.8824 "Coefficient of heat transfer at Ceiling Surface"; +14: Name 'windowarea_102' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_10. Affected line: parameter Modelica.Units.SI.Area windowarea_102=1.73 " Area Window102" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -20: Name 'R_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_U=EN_1264.R_U "Thermal resistance of wall layers under panel heating"; +15: Name 'windowarea_103' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_103. Affected line: parameter Modelica.Units.SI.Area windowarea_103=1.73 " Area Window103 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -21: Name 'R_O' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_, O. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_O=EN_1264.R_O "Thermal resistance of wall layers above panel heating"; +16: Name 'Tset_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bedroom. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bedroom=295.15 "Tset_bedroom" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); -22: Name 'sigma_i' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sigma_i. Affected line: final parameter Modelica.Units.SI.TemperatureDifference sigma_i=TSup_nominal - TRet_nominal "Temperature spread for room (max = 5 for room with highest heat load)" annotation (Dialog(group="Room Specifications")); +17: Name 'Tset_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children1=295.15 "Tset_children1" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -23: Name 'm_flow_PanelHeating' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_, Panel, Heating. Affected line: final parameter Modelica.Units.SI.MassFlowRate m_flow_PanelHeating=A* q_flow_nominal/(sigma_i*Cp_Medium)*(1 + (R_O/R_U) + (TZone_nominal - TZoneBel_nominal)/ (q_flow_nominal*R_U)) "nominal mass flow rate"; +18: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -24: Name 'm_flow_Circuit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_, Circuit. Affected line: final parameter Modelica.Units.SI.MassFlowRate m_flow_Circuit= m_flow_PanelHeating/nCircuits "Nominal mass flow rate in each heating circuit"; +19: Name 'Tset_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bath. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bath=297.15 "Tset_Bath" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); -25: Name 'K_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_. Affected line: final parameter Real K_H=EN_1264.K_H "Specific parameter for dimensioning according to EN 1264 that shows the relation between temperature difference and heat flux"; +20: Name 'Tset_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children2=295.15 "Tset_children2" annotation (Dialog( group="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -26: Name 'q_G' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, G. Affected line: final parameter Modelica.Units.SI.HeatFlux q_G=EN_1264.q_G "specific limiting heat flux"; +21: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); -27: Name 'dT_Hi' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_, Hi. Affected line: parameter Modelica.Units.SI.TemperatureDifference dT_Hi "Nominal temperature difference between heating medium" annotation (Dialog(group="Panel Heating")); +22: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); -28: Missing documentation, Name 'dT_HU' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: final parameter Modelica.Units.SI.TemperatureDifference dT_HU= UnderfloorHeating.BaseClasses.logDT({TSup_nominal,TRet_nominal,TZoneBel_nominal}); +23: Missing documentation, Name 'RoofS' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof, S. Affected line: AixLib.Utilities.Interfaces.SolarRad_in RoofS annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,44}))); -29: Name 'R_add' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_add. Affected line: final parameter Modelica.Units.SI.ThermalResistance R_add=1/(K_H*(1 + R_O/R_U* dT_Hi/dT_HU)*A + A*(TZone_nominal - TZoneBel_nominal)/(R_U*dT_HU)) - 1/(A/R_O + A/R_U* dT_Hi/dT_HU) - R_pipe - 1/(2200*Modelica.Constants.pi*dInn*length) "additional thermal resistance"; +24: Missing documentation, Name 'RoofN' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Roof, N. Affected line: AixLib.Utilities.Interfaces.SolarRad_in RoofN annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,76}))); -30: Name 'R_pipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_pipe. Affected line: final parameter Modelica.Units.SI.ThermalResistance R_pipe=if withSheathing then (log(dOut + thicknessSheathing/dOut))/(2*sheathingMaterial.lambda* Modelica.Constants.pi*length) + (log(dOut/dInn))/(2*pipeMaterial.lambda*Modelica.Constants.pi*length) else (log(dOut/dInn))/(2*pipeMaterial.lambda*Modelica.Constants.pi*length) "thermal resistance through pipe layers"; +25: Missing documentation, Name 'thermFloor_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bedroom[dis] annotation (Placement(transformation(extent={{-66,-122},{-46,-102}}))); -31: Name 'use_vmax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_vmax. Affected line: parameter Integer use_vmax(min=1, max=2) "Output if v > v_max (0.5 m/s)" annotation (choices(choice=1 "Warning", choice=2 "Error")); +26: Missing documentation, Name 'thermFloor_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children1[dis] annotation (Placement(transformation(extent={{-42,-120},{-22,-100}}))); -32: Missing documentation, Name 'calculateVol' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calculate. Affected line: parameter Integer calculateVol annotation (Dialog(group="Panel Heating", descriptionLabel=true), choices( choice=1 "Calculate Water Volume with inner diameter", choice=2 "Calculate Water Volume with time constant", radioButtons=true)); +27: Missing documentation, Name 'thermFloor_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Corridor[dis] annotation (Placement(transformation(extent={{-10,-120},{10,-100}}))); -33: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeatingCircuit circuits[nCircuits]( each final energyDynamics=energyDynamics, each final massDynamics=massDynamics, each final p_start=p_start, each final T_start=T_start, each final X_start=X_start, each final C_start=C_start, each final C_nominal=C_nominal, each final mSenFac=mSenFac, each final dp_Pipe=dpPipe_nominal, each final dp_Valve=dpValve_nominal, each final dpFixed_nominal=dpFixed_nominal, each final TSurMax=TSurMax, each final TRoom_nominal=TZone_nominal, each final pipeMaterial=pipeMaterial, each final thicknessPipe=thicknessPipe, each final dOut=dOut, each final withSheathing=withSheathing, each final sheathingMaterial=sheathingMaterial, redeclare each final package Medium = Medium, each final A=A/nCircuits, each final dis=dis, each final raiseErrorForMaxVelocity=raiseErrorForMaxVelocity, each final spacing=spacing, each m_flow_nominal=m_flow_Circuit, each final wallTypeFloor=wallTypeFloor, each final wallTypeCeiling=wallTypeCeiling, each R_x=R_add*nCircuits) "Underloor heating circuits" annotation (Placement(transformation(extent={{-20,-20},{20,20}})));BaseClasses.EN1264.HeatFlux EN_1264( lambda_E=lambda_E, wallTypeFloor=wallTypeFloor, wallTypeCeiling=wallTypeCeiling, R_lambdaIns=R_lambdaIns, alpha_Ceiling=alpha_Ceiling, T_U=TZoneBel_nominal, d_a=dOut, lambda_R=pipeMaterial.lambda, s_R=thicknessPipe, withSheathing=withSheathing, lambda_M=sheathingMaterial.lambda, s_u=CoverThickness, T_Fmax=TSurMax, T_Room=TZone_nominal, q_Gmax=q_Gmax, dT_H=dT_Hi, Ceiling=Ceiling, R_lambdaCeiling=R_lambdaCeiling, R_lambdaPlaster=R_lambdaPlaster, D=dOut + thicknessSheathing, T=spacing) annotation (Placement(transformation(extent={{-100,-60},{-60,-40}}))); +28: Missing documentation, Name 'thermFloor_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bath[dis] annotation (Placement(transformation(extent={{20,-120},{40,-100}}))); -34: Name 'portRadFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portRadFloor "Radiative heat port of floor" annotation (Placement(transformation(extent={{-50,90},{-30,110}}))); +29: Missing documentation, Name 'thermFloor_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children2[dis] annotation (Placement(transformation(extent={{60,-120},{80,-100}}))); -35: Name 'portConFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portConFloor "Convective heat port of floor" annotation (Placement(transformation(extent={{30,90},{50,110}}))); +30: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); -36: Name 'TFloorMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMax[nCircuits](unit="K", displayUnit="degC") "Maximum floor temperature" annotation (Placement(transformation(extent={{100,78},{120,98}}))); +31: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.Ow2IwL2IwS1Lf1At1Ro1 Bedroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5 + length6 + thickness_IWsimple, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length6, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_62, withWindow3=true, windowarea_RO=windowarea_63, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Bedroom, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-82,14},{-42,78}})));Rooms.Ow2IwL1IwS1Lf1At1Ro1 Children1( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_72, withWindow3=true, windowarea_RO=windowarea_73, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Children1, final T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,28},{44,76}})));Rooms.Ow2IwL1IwS1Lf1At1Ro1 Bath( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, room_length=length8, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_92, withDoor2=false, door_width_OD2=0, door_height_OD2=0, withWindow2=true, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Bath, final T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{84,-36},{46,-84}})));Rooms.Ow2IwL2IwS1Lf1At1Ro1 Children2( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length7 + length8 + thickness_IWsimple, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_102, withWindow3=true, windowarea_RO=windowarea_103, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length7, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Children2, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent= {{-84,-20},{-44,-84}})));Rooms.Ow1IwL2IwS1Lf1At1Ro1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, final solar_absorptance_OW=solar_absorptance_OW, room_length=length6 + length7 + thickness_IWsimple, room_lengthb=length7, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-28},{42,10}}))); -37: Name 'TFloorMea' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMea[nCircuits](unit="K", displayUnit="degC") "Mean floor temperature" annotation (Placement(transformation(extent={{100,38},{120,58}}))); +32: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,6}))); -38: Name 'TFloorMin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMin[nCircuits](unit="K", displayUnit="degC") "Minimal floor temperature" annotation (Placement(transformation(extent={{100,58},{120,78}}))); +33: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-24}))); -39: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); +34: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-54}))); -40: Name 'Cp_Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: parameter Modelica.Units.SI.SpecificHeatCapacity Cp_Medium=Medium.specificHeatCapacityCp(sta_default) "Specific Heat capacity of medium"; +35: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-84}))); +36: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-148,18},{-118,48}}))); -AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL1IwS1Gr1Uf1.mo -1: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +37: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-148,-26},{-118,4}}), iconTransformation(extent={{-130,-26},{-100,4}}))); -2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +38: Missing documentation, Name 'thermCeiling_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bedroom annotation (Placement(transformation(extent={{-98,100},{-82,118}}))); -3: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); +39: Missing documentation, Name 'thermCeiling_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children1 annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); -4: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +40: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); -5: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); +41: Missing documentation, Name 'thermCeiling_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bath annotation (Placement(transformation(extent={{20,100},{38,118}}))); -6: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +42: Missing documentation, Name 'thermCeiling_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children2 annotation (Placement(transformation(extent={{60,100},{78,118}}))); -7: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +43: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,-120},{120,-100}}))); -8: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +44: Missing documentation, Name 'heatStarToCombHeaters' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Heaters. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28}))); -9: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +45: Name 'portConvRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Conv, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); -10: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -11: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo +1: Name 'ports_b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_b ports_b[nPorts]( redeclare each final package Medium = Medium, m_flow(each max=if allowFlowReversal then +Modelica.Constants.inf else 0), h_outflow(each start = Medium.h_default), p(each start=Medium.p_default)) "Fluid connectors b (positive design flow direction is from port_a to port_b)" annotation (Placement(transformation(extent={{90,40},{110,-40}}))); -12: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -13: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeating.mo +1: Name 'v' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: v. Affected line: final parameter Modelica.Units.SI.Velocity v=V_flow_nominal/(Modelica.Constants.pi/4*dInn^(2)) "velocity of medium in pipe"; -14: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +2: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); -15: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +3: Name 'rho_default' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: rho_default. Affected line: parameter Modelica.Units.SI.Density rho_default=Medium.density(sta_default) "Density, used to compute fluid volume"; -16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, eps_door=eps_door_OD1, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation(extent={{-60,-22},{-50,42}}))); -17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={19,57}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/HeatFlux.mo +1: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling "false if ground plate is under panel heating" annotation (choices(checkBox=true)); -18: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={58,5}, extent={{-6,-35},{6,35}}, rotation=180))); +2: Name 'lambda_u' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u. Affected line: final parameter Modelica.Units.SI.ThermalConductivity lambda_u = lambda_E "Thermal conductivity of wall layers above panel heating without flooring (coverage)"; -19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) annotation (Placement(transformation( origin={16,-60}, extent={{-4,-24},{4,24}}, rotation=90))); +3: Name 'T_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: parameter Modelica.Units.SI.Temperature T_U=293.15 "Nominal Room Temperature lying under panel heating" annotation (Dialog(group="Room Specifications")); -20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_low_half, outside=false, wall_length=room_length, wall_height=room_width, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); +4: Name 'R_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_U = if Ceiling then R_lambdaIns + R_lambdaCeiling + R_lambdaPlaster + R_alphaCeiling else R_lambdaIns + R_lambdaCeiling + R_lambdaPlaster "Thermal resistance of wall layers under panel heating"; -21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final WindowType=Type_Win, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.groundPlate_upp_half, wall_length=room_length, wall_height=room_width, withWindow=false, outside=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin) if not use_UFH annotation (Placement(transformation( origin={-29,-65}, extent={{-3.00001,-15},{2.99998,15}}, rotation=90))); +5: Name 'R_O' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_, O. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_O = 1 / alpha_Floor + R_lambdaB + s_u / lambda_u "Thermal resistance of wall layers above panel heating"; -22: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); +6: Missing documentation, Name 'q_max' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q. Affected line: final parameter Modelica.Units.SI.HeatFlux q_max = K_H * dT_H; -23: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{80,0},{100,20}}))); +7: Missing documentation, Name 'q_U' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_. Affected line: final parameter Modelica.Units.SI.HeatFlux q_U = 1 / R_U * (R_O * q_max + T_Room - T_U); -24: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -25: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={50.5,99}, extent={{-10,-10},{10,10}}, rotation=270))); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow1IwL2IwS1Gr1Uf1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -26: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling if not use_UFH annotation (Placement(transformation(extent={{80,60},{100,80}}))); +2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -27: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); +3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +4: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/K_H_TypeA.mo -1: Name 'wallTypeCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Ceiling. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeCeiling "Wall type for ceiling" annotation (Dialog(group="Room Specifications", enable = Ceiling), choicesAllMatching=true); +5: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); -2: Name 'sheathingMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sheathing, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition sheathingMaterial "Sheathing Material" annotation (Dialog(group="Panel Heating", enable=withSheathing), choicesAllMatching=true); +6: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -3: Name 'pipeMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition pipeMaterial "Pipe Material" annotation (Dialog(group="Panel Heating"), choicesAllMatching=true); +7: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -4: Name 'alpha_Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Ceiling. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Ceiling= 5.8824 "Coefficient of heat transfer at floor surface"; +8: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -5: Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: parameter Boolean Ceiling = if wallTypeCeiling.n == 3 then true else false "false if ground plate is under panel heating" annotation (Dialog(group="Room Specifications"), choices(checkBox=true)); +9: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -6: Name 'lambda_R' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_R = pipeMaterial.lambda "Coefficient of heat transfer of pipe material"; +10: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -7: Missing documentation, Name 'lambda_R0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_, R0. Affected line: constant Modelica.Units.SI.ThermalConductivity lambda_R0 = 0.35; +11: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-60,-14},{-50,42}}))); -8: Name 's_R' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_. Affected line: parameter Modelica.Units.SI.Thickness s_R "thickness of pipe wall"; +12: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={23,59}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); -9: Missing documentation, Name 's_R0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_, R0. Affected line: constant Modelica.Units.SI.Thickness s_R0 = 0.002; +13: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,23}, extent={{-3,-15},{3,15}}, rotation=180))); -10: Name 'withSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Sheathing. Affected line: parameter Boolean withSheathing = true "false if pipe has no Sheathing" annotation (choices(checkBox=true)); +14: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={25,-59}, extent={{-5.00002,-29},{5.00001,29}}, rotation=90))); -11: Name 'D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: D. Affected line: parameter Modelica.Units.SI.Diameter D = d_a "Outer diameter of pipe including Sheathing" annotation (Dialog(enable = withSheathing)); +15: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-31,60}, extent={{2,-9},{-2,9}}, rotation=90))); -12: Missing documentation, Name 'd_M' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: d_, M. Affected line: final parameter Modelica.Units.SI.Diameter d_M = if withSheathing then D else 0; +16: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); -13: Name 'lambda_M' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_, M. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_M = sheathingMaterial.lambda "Thermal Conductivity for Sheathing" annotation (Dialog(enable = withSheathing)); +17: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); -14: Name 'lambda_E' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_. Affected line: parameter Modelica.Units.SI.ThermalConductivity lambda_E=wallTypeFloor.lambda[1] "Thermal conductivity of floor screed"; +18: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{34,-104},{54,-84}}))); -15: Name 'R_lambdaB0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, B0. Affected line: parameter Modelica.Units.SI.ThermalInsulance R_lambdaB0=if wallTypeFloor.n == 2 then wallTypeFloor.d[2]/wallTypeFloor.lambda[2] else 0 "Thermal resistance of flooring"; +19: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,20},{100,40}}))); -16: Name 'R_lambdaB' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, B. Affected line: parameter Modelica.Units.SI.ThermalInsulance R_lambdaB = if R_lambdaB0 < 0.1 then 0.1 else R_lambdaB0 "Thermal resistance of flooring used for dimensioning"; +20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement( transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation( extent={{-109.5,-70},{-89.5,-50}}))); -17: Name 'R_lambdaIns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaIns= wallTypeCeiling.d[1]/wallTypeCeiling.lambda[1] "Thermal resistance of thermal insulation"; +21: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,50},{-89.5,70}}))); -18: Name 'R_alphaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_alpha, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_alphaCeiling = if Ceiling then 1/alpha_Ceiling else 0 "Thermal resistance at the ceiling"; +22: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); -19: Name 'R_lambdaCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Ceiling. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaCeiling=if Ceiling then wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] else (wallTypeCeiling.d[2]/wallTypeCeiling.lambda[2] + wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] + wallTypeCeiling.d[4]/wallTypeCeiling.lambda[4]) "Thermal resistance of ceiling"; +23: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); -20: Name 'R_lambdaPlaster' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: R_lambda, Plaster. Affected line: final parameter Modelica.Units.SI.ThermalInsulance R_lambdaPlaster=if Ceiling then wallTypeCeiling.d[3]/wallTypeCeiling.lambda[3] else 0 "Thermal resistance of plaster"; +24: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); -21: Name 'B' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: B. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer B = if withSheathing == false then if lambda_R == 0.35 and s_R == 0.002 then 6.7 else if T <= 0.375 then (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_a / (d_a - 2 * s_R0))))^(-1) else (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * 0.375 * ( 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_a / (d_a - 2 * s_R0))))^(-1) else if T <= 0.375 then (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_M) * log(d_M / d_a) + 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_M / (d_M - 2 * s_R0))))^(-1) else (1 / B_0 + 1.1 / Modelica.Constants.pi * product_ai * T * ( 1 / (2 * lambda_M) * log(d_M / d_a) + 1 / (2 * lambda_R) * log(d_a / (d_a - 2 * s_R)) - 1 / (2 * lambda_R0) * log(d_M / (d_M - 2 * s_R0))))^(-1) "system dependent coefficient" annotation (Dialog(enable = false)); +25: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{20,80},{40,100}}))); -22: Name 'alpha_Floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: alpha_, Floor. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer alpha_Floor = 10.8 "Coefficient of heat transfer at floor surface"; -23: Missing documentation, Name 'lambda_u0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: lambda_u0. Affected line: constant Modelica.Units.SI.ThermalConductivity lambda_u0 = 1; +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL2IwS1Gr1Uf1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -24: Missing documentation, Name 's_u0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: s_u0. Affected line: constant Modelica.Units.SI.Diameter s_u0 = 0.045; +2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -25: Missing documentation, Name 'a_B' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_, B. Affected line: final parameter Real a_B = (1 / alpha_Floor + s_u0 / lambda_u0) / (1 / alpha_Floor + s_u0 / lambda_E + R_lambdaB); +3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -26: Missing documentation, Name 'a_T' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_. Affected line: final parameter Real a_T = determine_aT.y; +4: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); -27: Missing documentation. Affected line: final parameter Real a_u = determine_au.y; +5: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); -28: Missing documentation, Name 'a_D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: a_, D. Affected line: final parameter Real a_D = determine_aD.y; +6: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -29: Missing documentation, Name 'm_T' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_. Affected line: final parameter Real m_T = if T <= 0.375 then 1 - T / 0.075 else 1 - 0.375 / 0.075; +7: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); -30: Missing documentation. Affected line: final parameter Real m_u = 100 * (0.045 - s_u); +8: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -31: Missing documentation, Name 'm_D' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_, D. Affected line: final parameter Real m_D = 250 * (D - 0.02); +9: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); -32: Name 'product_ai' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: product_ai. Affected line: final parameter Real product_ai = a_B * a_T^(m_T) * a_u^(m_u) * a_D^(m_D) "product of powers for parameters of floor heating"; +10: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -33: Missing documentation, Name 'K_H' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer K_H = if s_u > s_uStar and s_u > 0.065 then 1 / ( (1 / K_HStar) + ((s_u - s_uStar) / lambda_E)) else if T > 0.375 then B * product_ai * 0.375 / T else B * product_ai; +11: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -34: Missing documentation, Name 's_uStar' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Star. Affected line: protected final parameter Modelica.Units.SI.Thickness s_uStar = if T > 0.2 then (0.5 * T) else 0.1; +12: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -35: Missing documentation, Name 'K_HStar' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: K_, Star. Affected line: final parameter Modelica.Units.SI.CoefficientOfHeatTransfer K_HStar = B * a_B * a_T^(m_T) * a_u^(100*(0.045-s_uStar)) * a_D^(m_D); +13: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -36: Missing documentation. Affected line: import Modelica.Math.log; +14: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +15: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialModularPort_ab.mo -1: Name 'ports_b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_b ports_b[nPorts]( redeclare each final package Medium = Medium, m_flow(each max=if allowFlowReversal then +Modelica.Constants.inf else 0), h_outflow(each start = Medium.h_default), p(each start=Medium.p_default)) "Fluid connectors b (positive design flow direction is from port_a to port_b)" annotation (Placement(transformation(extent={{90,40},{110,-40}}))); +16: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +17: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/SimpleRoom/OneRoomSimple.mo -1: Missing documentation, Name 'MediumAir' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: package MediumAir = AixLib.Media.Air; +18: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-58,-16},{-48,42}}))); -2: Missing documentation, Name 'MediumWater' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium, Water. Affected line: package MediumWater = AixLib.Media.Water; +19: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={23,57}, extent={{-4.99998,-27},{5.00001,27}}, rotation=270))); -3: Missing documentation, Name 'area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: area. Affected line: parameter Modelica.Units.SI.Area area=20; +20: Missing documentation, Name 'inside_wall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,22}, extent={{-2.99999,-16},{2.99999,16}}, rotation=180))); -4: Missing documentation. Affected line: AixLib.Fluid.MixingVolumes.MixingVolume vol( redeclare package Medium = MediumAir, m_flow_nominal=0.1, V=area*3) annotation (Placement(transformation(extent={{-10,12},{10,32}}))); +21: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={22,-62}, extent={{-4.00002,-26},{4.00001,26}}, rotation=90))); -5: Missing documentation, Name 'fixedHeatFlow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow(Q_flow=-1000) annotation (Placement(transformation(extent={{-40,74},{-20,94}}))); +22: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); -6: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = MediumWater, nZones=1, dis=dis, Q_flow_nominal=-1.*{fixedHeatFlow.Q_flow}, A={area}, wallTypeFloor={ UnderfloorHeating.BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH()}, Ceiling={false}, wallTypeCeiling={UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy()}, Spacing={0.35}, thicknessPipe={0.002}, dOut={0.017}, withSheathing=false) annotation (Placement(transformation(extent={{-32,-64},{18,-34}}))); +23: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=2) if not use_UFH annotation (Placement(transformation( origin={-27,-62}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); -7: Missing documentation, Name 'thermalConductor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thermal, Conductor. Affected line: Modelica.Thermal.HeatTransfer.Components.ThermalConductor thermalConductor[dis]( each G=area/dis*10.8) annotation (Placement(transformation(extent={{-4,-12},{-24,8}}))); +24: Missing documentation, Name 'inside_wall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); -8: Missing documentation, Name 'fixedHeatFlow1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlow1(Q_flow=0) annotation (Placement(transformation(extent={{58,-100},{38,-80}}))); +25: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); -9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[1](each k=1) annotation (Placement(transformation(extent={{-100,-26},{-86,-12}}))); +26: Missing documentation, Name 'thermInsideWall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1a annotation (Placement(transformation(extent={{80,20},{100,40}}))); -10: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.MassFlowSource_T boundary( redeclare package Medium = MediumWater, m_flow=underfloorHeatingSystem.m_flow_nominal, T=underfloorHeatingSystem.T_Vdes, nPorts=1) annotation (Placement(transformation(extent={{-98,-58},{-78,-38}}))); +27: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); -11: Missing documentation. Affected line: AixLib.Fluid.Sources.Boundary_pT bou(redeclare package Medium = MediumWater, nPorts=1) annotation (Placement(transformation(extent={{74,-60},{54,-40}}))); +28: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +29: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={50.5,101}, extent={{-10,-10},{10,10}}, rotation=270), iconTransformation( extent={{-10,-10},{10,10}}, rotation=270, origin={50.5,99}))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/UpperFloorBuildingEnvelope.mo -1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); +30: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); -2: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2.28 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +31: Missing documentation, Name 'thermInsideWall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); -3: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2.60 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +32: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); -4: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=1 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -5: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2.21 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/GroundFloorBuildingEnvelope.mo +1: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.60 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -6: Documentation too short, Name 'length5' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length5. Affected line: parameter Modelica.Units.SI.Length length5=3.3 "l5 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +2: Documentation too short, Name 'length1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length1=3.3 "l1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -7: Documentation too short, Name 'length6' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length6. Affected line: parameter Modelica.Units.SI.Length length6=2.44 "l6 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +3: Documentation too short, Name 'length2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length. Affected line: parameter Modelica.Units.SI.Length length2=2.44 "l2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -8: Documentation too short, Name 'length7' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length7. Affected line: parameter Modelica.Units.SI.Length length7=1.33 "l7 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +4: Documentation too short, Name 'length3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length3. Affected line: parameter Modelica.Units.SI.Length length3=1.33 "l3 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Documentation too short, Name 'length8' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length8. Affected line: parameter Modelica.Units.SI.Length length8=3.3 "l8 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +5: Documentation too short, Name 'length4' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: length4. Affected line: parameter Modelica.Units.SI.Length length4=3.3 "l4 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +6: Name 'thickness_IWsimple' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness_, Wsimple. Affected line: parameter Modelica.Units.SI.Length thickness_IWsimple=0.145 "thickness IWsimple " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -11: Name 'windowarea_63' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_63. Affected line: parameter Modelica.Units.SI.Area windowarea_63=1.73 " Area Window63 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +7: Name 'windowarea_12' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_1. Affected line: parameter Modelica.Units.SI.Area windowarea_12=1.73 " Area Window12 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -12: Name 'windowarea_72' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_7. Affected line: parameter Modelica.Units.SI.Area windowarea_72=1.73 " Area Window72" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +8: Name 'windowarea_22' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_2. Affected line: parameter Modelica.Units.SI.Area windowarea_22=1.73 " Area Window22" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -13: Name 'windowarea_73' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_73. Affected line: parameter Modelica.Units.SI.Area windowarea_73=1.73 " Area Window73 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +9: Name 'windowarea_41' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_4. Affected line: parameter Modelica.Units.SI.Area windowarea_41=1.4 " Area Window41 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -14: Name 'windowarea_92' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_9. Affected line: parameter Modelica.Units.SI.Area windowarea_92=1.73 " Area Window51" annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +10: Name 'windowarea_51' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_51=3.46 " Area Window51" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); -15: Name 'windowarea_102' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_10. Affected line: parameter Modelica.Units.SI.Area windowarea_102=1.73 " Area Window102" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, joinNext=true)); +11: Name 'windowarea_52' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_5. Affected line: parameter Modelica.Units.SI.Area windowarea_52=1.73 " Area Window52 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -16: Name 'windowarea_103' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_103. Affected line: parameter Modelica.Units.SI.Area windowarea_103=1.73 " Area Window103 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); +12: Name 'door_width_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_3. Affected line: parameter Modelica.Units.SI.Length door_width_31=1.01 "Width Door31" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); -17: Name 'Tset_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bedroom. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bedroom=295.15 "Tset_bedroom" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +13: Name 'door_height_31' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_3. Affected line: parameter Modelica.Units.SI.Length door_height_31=2.25 "Height Door31 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -18: Name 'Tset_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children1=295.15 "Tset_children1" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +14: Name 'door_width_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_4. Affected line: parameter Modelica.Units.SI.Length door_width_42=1.25 "Width Door42" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true)); -19: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +15: Name 'door_height_42' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_4. Affected line: parameter Modelica.Units.SI.Length door_height_42=2.25 "Height Door42 " annotation (Dialog(group="Windows and Doors", descriptionLabel=true)); -20: Name 'Tset_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Bath. Affected line: parameter Modelica.Units.SI.Temperature Tset_Bath=297.15 "Tset_Bath" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); +16: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation ( Dialog( tab="Outer walls", group="Doors")); -21: Name 'Tset_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Children. Affected line: parameter Modelica.Units.SI.Temperature Tset_Children2=295.15 "Tset_children2" annotation (Dialog( group="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); +17: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors(min=0, max=1)=0.95 "Emissivity of inside surface of outer doors" annotation ( Dialog( tab="Outer walls", group="Doors")); -22: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); +18: Name 'Tset_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Hobby. Affected line: parameter Modelica.Units.SI.Temperature Tset_Hobby=295.15 "Tset_hobby" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -23: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); +19: Name 'Tset_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Corridor. Affected line: parameter Modelica.Units.SI.Temperature Tset_Corridor=291.15 "Tset_corridor" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -24: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in RoofS annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,64})));Utilities.Interfaces.SolarRad_in RoofN annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88}))); +20: Name 'Tset_WC' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, W. Affected line: parameter Modelica.Units.SI.Temperature Tset_WC=291.15 "Tset_WC" annotation ( Dialog( tab="Dynamic ventilation", descriptionLabel=true, joinNext=true, enable=withDynamicVentilation)); -25: Missing documentation, Name 'thermFloor_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bedroom if not use_UFH annotation (Placement(transformation(extent={{-66,-120},{-46,-100}}))); +21: Name 'Tset_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset_, Kitchen. Affected line: parameter Modelica.Units.SI.Temperature Tset_Kitchen=295.15 "Tset_kitchen" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=withDynamicVentilation)); -26: Missing documentation, Name 'thermFloor_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children1 if not use_UFH annotation (Placement(transformation(extent={{-42,-120},{-22,-100}}))); +22: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.Ow2IwL2IwS1Gr1Uf1 Livingroom( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length2, room_width=room_width, room_height=room_height, room_length=length1 + length2 + thickness_IWsimple, final solar_absorptance_OW=solar_absorptance_OW, windowarea_OW1=windowarea_11, windowarea_OW2=windowarea_12, withDoor1=false, withDoor2=false, withWindow1=true, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Livingroom, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-84,12},{-40,76}})));Rooms.Ow2IwL1IwS1Gr1Uf1 Hobby( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length1, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, windowarea_OW2=windowarea_22, withDoor1=false, withDoor2=false, withWindow1=false, withWindow2=true, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Hobby, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{84,28},{46,76}})));Rooms.Ow2IwL1IwS1Gr1Uf1 WC_Storage( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length4, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_41, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withDoor2=true, door_width_OD2=door_width_42, door_height_OD2=door_height_42, withWindow2=false, withDoor1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_WC, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-36},{44,-84}})));Rooms.Ow2IwL2IwS1Gr1Uf1 Kitchen( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, room_length=length3 + length4 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withWindow1=true, windowarea_OW1=windowarea_51, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, withWindow2=true, windowarea_OW2=windowarea_52, room_lengthb=length3, withDoor1=false, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, withDynamicVentilation=withDynamicVentilation, HeatingLimit=HeatingLimit, Max_VR=Max_VR, Diff_toTempset=Diff_toTempset, Tset=Tset_Kitchen, final T0_air=T0_air, final U_door_OD2=UValOutDoors, final eps_door_OD2=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent= {{-84,-20},{-44,-84}})));Rooms.Ow1IwL2IwS1Gr1Uf1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, energyDynamicsWalls=energyDynamicsWalls, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final Type_Win=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, dis=dis, withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, room_length=length2 + length3 + thickness_IWsimple, room_width=room_width, room_height=room_height, final solar_absorptance_OW=solar_absorptance_OW, withDoor1=true, door_width_OD1=door_width_31, door_height_OD1=door_height_31, final U_door_OD1=UValOutDoors, final eps_door_OD1=epsOutDoors, room_lengthb=length3, withWindow1=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{82,-28},{42,10}}))); -27: Missing documentation, Name 'thermFloor_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Corridor if not use_UFH annotation (Placement(transformation(extent={{-10,-120},{10,-100}}))); +23: Missing documentation, Name 'North' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: North. Affected line: AixLib.Utilities.Interfaces.SolarRad_in North annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,88}))); -28: Missing documentation, Name 'thermFloor_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Bath if not use_UFH annotation (Placement(transformation(extent={{20,-120},{40,-100}}))); +24: Missing documentation, Name 'East' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: East. Affected line: AixLib.Utilities.Interfaces.SolarRad_in East annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,60}))); -29: Missing documentation, Name 'thermFloor_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor_Children2 if not use_UFH annotation (Placement(transformation(extent={{60,-120},{80,-100}}))); +25: Missing documentation, Name 'South' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: South. Affected line: AixLib.Utilities.Interfaces.SolarRad_in South annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,26}))); -30: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Rooms.OFD.Ow2IwL2IwS1Lf1At1Ro1 Bedroom( final denAir=denAir, final cAir=cAir, final use_UFH=use_UFH, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5 + length6 + thickness_IWsimple, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length6, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_62, withWindow3=true, windowarea_RO=windowarea_63, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Bedroom, T0_air=T0_air, nPorts=2, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-82,14},{-42,78}})));Rooms.OFD.Ow2IwL1IwS1Lf1At1Ro1 Children1( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length5, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_72, withWindow3=true, windowarea_RO=windowarea_73, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Children1, T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{78,28}, {40,76}})));Rooms.OFD.Ow2IwL1IwS1Lf1At1Ro1 Bath( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, room_length=length8, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_92, withDoor2=false, door_width_OD2=0, door_height_OD2=0, withWindow2=true, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Bath, T0_air=T0_air, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, nPorts=2, final use_UFH=use_UFH, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{80,-36}, {42,-84}})));Rooms.OFD.Ow2IwL2IwS1Lf1At1Ro1 Children2( final denAir=denAir, final cAir=cAir, final use_UFH=use_UFH, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final solar_absorptance_OW=solar_absorptance_OW, withWindow2=true, room_length=length7 + length8 + thickness_IWsimple, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, windowarea_OW2=windowarea_102, withWindow3=true, windowarea_RO=windowarea_103, final eps_door_OD2=epsOutDoors, final U_door_OD2=UValOutDoors, room_lengthb=length7, withDoor2=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Children2, T0_air=T0_air, nPorts=2, redeclare package Medium = Medium) annotation (Placement(transformation(extent={{-84,-20},{-44,-84}})));Rooms.OFD.Ow1IwL2IwS1Lf1At1Ro1 Corridor( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=Tset_Corridor, final solar_absorptance_OW=solar_absorptance_OW, room_length=length6 + length7 + thickness_IWsimple, room_lengthb=length7, room_width_long=room_width_long, room_width_short=room_width_short, room_height_long=room_height_long, room_height_short=room_height_short, roof_width=roof_width, final solar_absorptance_RO=solar_absorptance_RO, withWindow3=false, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final T0_air=T0_air, nPorts=2, final use_UFH=use_UFH, redeclare final package Medium = Medium) annotation (Placement(transformation(extent={{78,-28},{ 38,10}})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,40})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,16})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-10})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-36}))); +26: Missing documentation, Name 'West' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: West. Affected line: AixLib.Utilities.Interfaces.SolarRad_in West annotation (Placement( transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={110,-16}))); -31: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-130,10},{-100,40}}))); +27: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-130,12},{-100,42}}))); -32: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-130,-26},{-100,4}}), iconTransformation(extent={{-130,-26},{-100,4}}))); +28: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-130,-18},{-100,12}}))); -33: Missing documentation, Name 'thermCeiling_Bedroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bedroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bedroom annotation (Placement(transformation(extent={{-98,100},{-82,118}}))); +29: Missing documentation, Name 'thermCeiling_Livingroom' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Livingroom. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Livingroom[dis] annotation (Placement(transformation(extent={{-100,100},{-84,118}}))); -34: Missing documentation, Name 'thermCeiling_Children1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children1 annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); +30: Missing documentation, Name 'thermCeiling_Hobby' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Hobby. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Hobby[dis] annotation (Placement(transformation(extent={{-58,100},{-40,118}}))); -35: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); +31: Missing documentation, Name 'thermCeiling_Corridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Corridor[dis] annotation (Placement(transformation(extent={{-20,100},{-2,118}}))); -36: Missing documentation, Name 'thermCeiling_Bath' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Bath. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Bath annotation (Placement(transformation(extent={{20,100},{38,118}}))); +32: Missing documentation, Name 'thermCeiling_WCStorage' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, W, Storage. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_WCStorage[dis] annotation (Placement(transformation(extent={{20,100},{38,118}}))); -37: Missing documentation, Name 'thermCeiling_Children2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Children. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Children2 annotation (Placement(transformation(extent={{60,100},{78,118}}))); +33: Missing documentation, Name 'thermCeiling_Kitchen' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling_, Kitchen. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling_Kitchen[dis] annotation (Placement(transformation(extent={{62,100},{80,118}}))); -38: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,-120},{120,-100}}))); +34: Missing documentation, Name 'thermCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Corridor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCorridor annotation (Placement(transformation(extent={{100,100},{120,120}}))); -39: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28})));Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1(6): Bedroom_UF, 2(7): Child1_UF, 3(8): Corridor_UF, 4(9): Bath_UF, 5(10): Child2_UF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); +35: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5*dis] "HeatPort to force a ground temperature for the ground level's floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}))); -40: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[5](redeclare final package Medium = Medium) "Inlet for ventilation" annotation (Placement( transformation(extent={{94,-78},{114,-58}}), iconTransformation(extent={ {94,-70},{108,-56}}))); +36: Missing documentation, Name 'heatStarToCombHeaters' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb, Heaters. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombHeaters[5] annotation (Placement(transformation( extent={{10,-8},{-10,8}}, rotation=90, origin={0,-28}))); -41: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[5](redeclare final package Medium = Medium) "Outlet of Ventilation" annotation (Placement( transformation(extent={{94,-94},{114,-74}}), iconTransformation(extent={ {94,-94},{108,-80}}))); +37: Name 'portConvRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Conv, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb portConvRadRooms[5] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor, 4: WC_Storage_GF, 5: Kitchen_GF" annotation (Placement(transformation(extent={{-10,-10},{10,10}}))); -42: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); +38: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-114,90},{-94,110}}))); AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL2IwS1Lf1At1Ro1.mo @@ -1545,246 +1555,212 @@ AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDisc 33: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-126,-76},{-99.5,-50}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); -AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomParams.mo -1: Name 'use_UFH' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: F. Affected line: parameter Boolean use_UFH = false "If underfloor heating, conductive wall layers in floor and ceiling are disabled" annotation(Dialog(group = "Structure of wall layers")); - -2: Name 'wallTypes' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Types. Affected line: replaceable parameter AixLib.DataBase.Walls.Collections.BaseDataMultiWalls wallTypes constrainedby AixLib.DataBase.Walls.Collections.BaseDataMultiWalls "Types of walls (contains multiple records)" annotation(Dialog(group = "Structure of wall layers"), choicesAllMatching = true, Placement(transformation(extent={{-8,82},{8,98}}))); - -3: Name 'energyDynamicsWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: energy, Dynamics, Walls. Affected line: parameter Modelica.Fluid.Types.Dynamics energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.DynamicFreeInitial "Type of energy balance for wall capacities: dynamic (3 initialization options) or steady state" annotation(Evaluate=true, Dialog(tab="Dynamics")); - -4: Documentation too short, Name 'T0_air' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T0_air. Affected line: parameter Modelica.Units.SI.Temperature T0_air=295.11 "Air" annotation (Dialog(tab="Initialization", group="Air volume of room")); - -5: Name 'TWalls_start' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Walls. Affected line: parameter Modelica.Units.SI.Temperature TWalls_start= Modelica.Units.Conversions.from_degC(16) "Initial temperature of all walls" annotation (Dialog(tab="Initialization", group="Walls")); - -6: Name 'radLongCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Long, Calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer radLongCalcMethod=AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx "Calculation method for longwave radiation heat transfer" annotation ( Evaluate=true, Dialog(tab="Inner walls", group="Longwave radiation", compact=true)); - -7: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization of longwave radiation" annotation (Dialog( tab="Inner walls", group="Longwave radiation", enable=radLongCalcMethod == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_constant_T_ref)); - -8: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.WindowsDoors.Simple.OWBaseDataDefinition_Simple Type_Win "Window parametrization" annotation (Dialog(tab="Outer walls", group="Windows"), choicesAllMatching = true); - -9: Name 'CorrSolarGainWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Corr, Solar. Affected line: replaceable model CorrSolarGainWin = AixLib.ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.PartialCorG constrainedby AixLib.ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.PartialCorG "Correction model for solar irradiance as transmitted radiation" annotation (choicesAllMatching=true, Dialog(tab="Outer walls", group="Windows", enable = withWindow and outside)); - -10: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter DataBase.Surfaces.RoughnessForHT.PolynomialCoefficients_ASHRAEHandbook surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster() "Surface type of outside wall" annotation (Dialog(tab="Outer walls", group="Heat convection", enable=(calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals))); - -11: Name 'ratioSunblind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ratio, Sunblind. Affected line: parameter Real ratioSunblind(min=0.0, max=1.0) = 0.8 "Sunblind factor. 1 means total blocking of irradiation, 0 no sunblind" annotation(Dialog(tab="Outer walls", group = "Sunblind", enable=use_sunblind)); - -12: Name 'solIrrThreshold' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Threshold. Affected line: parameter Modelica.Units.SI.Irradiance solIrrThreshold(min=0.0) = 350 "Threshold for global solar irradiation on this surface to enable sunblinding (see also TOutAirLimit)" annotation (Dialog( tab="Outer walls", group="Sunblind", enable=use_sunblind)); - -13: Name 'TOutAirLimit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Limit. Affected line: parameter Modelica.Units.SI.Temperature TOutAirLimit=293.15 "Temperature at which sunblind closes (see also solIrrThreshold)" annotation (Dialog( tab="Outer walls", group="Sunblind", enable=use_sunblind)); - -14: Name 'e' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: e. Affected line: parameter Real e=0.03 "Coefficient of windshield" annotation (Dialog(tab="Infiltration acc. to EN 12831 (airtightness)", enable=use_infiltEN12831)); - -15: Name 'HeatingLimit' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heating, Limit. Affected line: parameter Modelica.Units.SI.Temperature HeatingLimit=288.15 "Outside temperature at which the heating activates" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); - -16: Name 'Max_VR' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Max_. Affected line: parameter Real Max_VR=10 "Maximal ventilation rate" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); - -17: Name 'Diff_toTempset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Diff_to, Tempset. Affected line: parameter Modelica.Units.SI.TemperatureDifference Diff_toTempset=2 "Difference to set temperature" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); - -18: Documentation too short, Name 'Tset' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Tset. Affected line: parameter Modelica.Units.SI.Temperature Tset=295.15 "Tset" annotation (Dialog( tab="Dynamic ventilation", descriptionLabel=true, enable=if withDynamicVentilation then true else false)); +AixLib/ThermalZones/HighOrder/Rooms/BaseClasses/PartialRoomFourWalls.mo +1: Name 'room_length' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_length. Affected line: parameter Modelica.Units.SI.Length room_length=6 "length" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +2: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2.7 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -AixLib/ThermalZones/HighOrder/Components/Walls/BaseClasses/ConvNLayerClearanceStar.mo -1: Name 'l' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: l. Affected line: parameter Modelica.Units.SI.Length l "Length" annotation (Dialog(group="Geometry")); +3: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=8 "width" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -2: Name 'clearance' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: clearance. Affected line: parameter Modelica.Units.SI.Area clearance=0 "Area of clearance" annotation (Dialog(group="Geometry")); +4: Name 'Win_Area' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Win_, Area. Affected line: parameter Modelica.Units.SI.Area Win_Area=12 "Window area " annotation ( Dialog( group="Windows", descriptionLabel=true)); -3: Name 'use_condLayers' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_cond, Layers. Affected line: parameter Boolean use_condLayers = true "Use conductive wall layers" annotation(Dialog(group = "Structure of wall layers")); +5: Name 'use_shortWaveRadIn' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_short, Wave. Affected line: parameter Boolean use_shortWaveRadIn=true "Use bus connector for incoming shortwave radiation" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation")); -4: Name 'wallType' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallType constrainedby AixLib.DataBase.Walls.WallBaseDataDefinition "Type of wall" annotation(Dialog(group = "Structure of wall layers", enable=use_condLayers), choicesAllMatching = true, Placement(transformation(extent={{48,-98},{68,-78}}))); +6: Name 'use_shortWaveRadOut' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_short, Wave. Affected line: parameter Boolean use_shortWaveRadOut=true "Use bus connector for outgoing shortwave radiation" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable=use_shortWaveRadIn)); -5: Name 'calcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface calcMethod= AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransferInsideSurface.Bernd_Glueck "Calculation method for convective heat transfer coefficient at inside surface" annotation (Dialog( group="Convection", descriptionLabel=true)); +7: Name 'use_dynamicShortWaveRadMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: use_dynamic, Short, Wave, Method. Affected line: parameter Boolean use_dynamicShortWaveRadMethod=false "True = dynamic as holistic approach, false = static approach to obtain the same values as provided in tables of the ASHREA" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn)); -6: Name 'radCalcMethod' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Calc, Method. Affected line: parameter AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer radCalcMethod= AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.No_approx "Calculation method for radiation heat transfer" annotation ( Evaluate=true, Dialog(group = "Radiation", compact=true)); +8: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: parameter Components.Types.selectorCoefficients absInnerWallSurf=AixLib.ThermalZones.HighOrder.Components.Types.selectorCoefficients.abs06 "Coefficients for interior solar absorptance of wall surface abs={0.6, 0.9, 0.1}" annotation (Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn and not use_dynamicShortWaveRadMethod)); -7: Name 'T_ref' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_ref. Affected line: parameter Modelica.Units.SI.Temperature T_ref= Modelica.Units.Conversions.from_degC(16) "Reference temperature for optional linearization" annotation (Dialog(group="Radiation", enable=radCalcMethod == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodRadiativeHeatTransfer.Linear_constant_T_ref)); +9: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: replaceable parameter ThermalZones.HighOrder.Components.Types.CoeffTableEastWestWindow coeffTableSolDistrFractions constrainedby AixLib.ThermalZones.HighOrder.Components.Types.PartialCoeffTable(final abs=absInnerWallSurf) "Record holding the values to reproduce the tables" annotation (choicesAllMatching=true, Dialog(tab="Inner walls", group="Shortwave Radiation", enable= use_shortWaveRadIn and not use_dynamicShortWaveRadMethod), Placement(transformation(extent={{78,78},{98,98}}))); -8: Name 'T0' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T0. Affected line: parameter Modelica.Units.SI.Temperature T0= Modelica.Units.Conversions.from_degC(16) "Initial temperature" annotation (Dialog(group="Thermal")); +10: Missing documentation, Name 'wallSouth' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, South. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallSouth( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, wall_length=room_width, solar_absorptance=solar_absorptance_OW, calcMethodOut=calcMethodOut, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, wall_height=room_height, surfaceType=AixLib.DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster()) annotation (Placement(transformation( extent={{-5,-35},{5,35}}, rotation=90, origin={18,-68}))); -9: Missing documentation, Name 'radPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Port. Affected line: AixLib.Utilities.Interfaces.RadPort radPort annotation (Placement(transformation(extent={{90,52},{110,72}}))); +11: Missing documentation, Name 'wallWest' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, West. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallWest( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-5,-27},{5,27}}, rotation=0, origin={-83,13}))); -10: Missing documentation, Name 'twoStar_RadEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Star_, Ex. Affected line: AixLib.Utilities.HeatTransfer.HeatToRad twoStar_RadEx( final A=A, final eps=wallType.eps, final radCalcMethod=radCalcMethod, final T_ref=T_ref) annotation (Placement(transformation(extent={{54,30},{74,50}}))); +12: Missing documentation, Name 'wallEast' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, East. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallEast( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-5,-27},{5,27}}, rotation=180, origin={69,13}))); -11: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a annotation ( Placement(transformation(extent={{-110,-10},{-90,10}}), iconTransformation(extent={{-110,-10},{-90,10}}))); +13: Missing documentation, Name 'wallNorth' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, North. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall wallNorth( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_height=room_height, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, wall_length=room_width, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{5.00001,-30},{-5.00001,30}}, rotation=90, origin={18,69}))); -12: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b port_b annotation ( Placement(transformation(extent={{90,-10},{110,10}}), iconTransformation( extent={{90,-10},{110,10}}))); +14: Missing documentation, Name 'ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall ceiling( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_width, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, solar_absorptance=solar_absorptance_OW, surfaceType=DataBase.Surfaces.RoughnessForHT.Brick_RoughPlaster(), calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-2,-12},{2,12}}, rotation=270, origin={-42,80}))); -13: Missing documentation, Name 'simpleNLayer' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: simple, N, Layer. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.BaseClasses.SimpleNLayer simpleNLayer( final A=A, each final T_start=fill(T0, n), final wallRec=wallType, final energyDynamics=energyDynamics) annotation (Placement(transformation(extent={{-14,-12},{12,12}}))); +15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( use_shortWaveRadIn=use_shortWaveRadIn, use_shortWaveRadOut=use_shortWaveRadOut, outside=false, energyDynamics=energyDynamicsWalls, radLongCalcMethod=radLongCalcMethod, T_ref=T_ref, calcMethodIn=calcMethodIn, wall_length=room_length, wall_height=room_width, WindowType=Type_Win, redeclare model WindowModel = WindowModel, redeclare model CorrSolarGainWin = CorrSolarGainWin, T0=TWalls_start, solar_absorptance=solar_absorptance_OW, withSunblind=use_sunblind, Blinding=1 - ratioSunblind, LimitSolIrr=solIrrThreshold, TOutAirLimit=TOutAirLimit, calcMethodOut=calcMethodOut) annotation (Placement(transformation( extent={{-2.00031,-12},{2.00003,12}}, rotation=90, origin={-42,-68}))); -14: Missing documentation, Name 'port_b1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: port_b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_b port_b1 annotation ( Placement(transformation(extent={{-10,88},{10,108}}), iconTransformation( extent={{-12,88},{8,108}}))); +16: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort[5] "N,E,S,W,Hor" annotation (Placement(transformation(extent={{-120,46},{-100,66}}), iconTransformation(extent={{-120,46},{-100,66}}))); -15: Missing documentation. Affected line: parameter Modelica.Units.SI.Area A = h * l - clearance annotation(Dialog(enable = false)); +17: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort annotation (Placement(transformation(extent={{-116,28},{-100,44}}), iconTransformation(extent={{-120,-16},{-100,4}}))); +18: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.HeatTransfer.SolarRadInRoom solarRadInRoom( final use_dynamicMethod=use_dynamicShortWaveRadMethod, final nWalls=4, final nWin=nWin, final nFloors=1, final nCei=1, final floor_length=room_length, final floor_width=room_height, final staticCoeffTable=coeffTableSolDistrFractions) if use_shortWaveRadIn and nWin > 0 annotation (Placement(transformation(extent={{-50,26},{-30,46}}))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/OFDHeatLoad.mo -1: Missing documentation, Name 'nRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Rooms. Affected line: parameter Integer nRooms = 11; +19: Documentation too short, Name 'transShoWaveRadWin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: trans, Wave. Affected line: Modelica.Blocks.Interfaces.RealOutput transShoWaveRadWin(final quantity="Power", final unit="W") if use_shortWaveRadOut annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={60,-110}))); -2: Missing documentation, Name 'nHeatedRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heated, Rooms. Affected line: parameter Integer nHeatedRooms = 10; +20: Missing documentation, Name 'multiSum' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: multi. Affected line: Modelica.Blocks.Math.MultiSum multiSum(nu=nWin) if use_shortWaveRadOut annotation (Placement(transformation( extent={{2,-2},{-2,2}}, rotation=90, origin={60,-96}))); -3: Missing documentation. Affected line: parameter Integer dis = wholeHouseBuildingEnvelope.dis; +21: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected Utilities.Interfaces.ShortRadSurf shortRadSurf[nWin] if use_shortWaveRadOut annotation (Placement(transformation(extent={{58,-92}, {62,-88}}), iconTransformation(extent={{58,-92}, {62,-88}}))); -4: Name 'constRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Rooms. Affected line: Modelica.Blocks.Sources.Constant constRooms[nHeatedRooms](k={293.15,293.15,293.15, 293.15,293.15,293.15,293.15,293.15,293.15,293.15}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,-62},{-50,-42}}))); +22: Missing documentation, Name 'usesWindow' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: uses, Window. Affected line: protected parameter Boolean usesWindow[4] = {wallEast.withWindow, wallSouth.withWindow, wallWest.withWindow, wallNorth.withWindow}; -5: Name 'constAirEx' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ex. Affected line: Modelica.Blocks.Sources.Constant constAirEx[nRooms](k={0.5,0.5,0,0.5,0.5,0.5,0.5,0,0.5,0.5,0}) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-70,6},{-50,26}}))); +23: Missing documentation, Name 'usesWindowInt' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: uses, Window. Affected line: parameter Integer usesWindowInt[4] = {if usesWindow[i] then 1 else 0 for i in 1:size(usesWindow, 1)}; -6: Missing documentation, Name 'constWind' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind. Affected line: Modelica.Blocks.Sources.Constant constWind(k=0) annotation (Placement(transformation(extent={{-70,36},{-50,56}}))); -7: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constAmb(k=261.15) annotation (Placement(transformation(extent={{-70,70},{-50,90}}))); +AixLib/ThermalZones/HighOrder/Rooms/OFD/Ow2IwL2IwS1Lf1At1Ro1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -8: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature groundTemp[5](T=fill( 273.15 + 8.5, 5)) annotation (Placement(transformation(extent={{-54,-96},{-42,-84}}))); +2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -9: Missing documentation, Name 'prescribedTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedTemperature[nHeatedRooms] annotation (Placement(transformation(extent={{-36,-58},{-24,-46}}))); +3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -10: Missing documentation, Name 'heatStarToComb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToComb[nRooms] annotation (Placement(transformation( extent={{8,-6},{-8,6}}, rotation=0, origin={-36,-20}))); +4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -11: Missing documentation, Name 'prescribedAmbTemperature' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Temperature. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature prescribedAmbTemperature annotation (Placement(transformation(extent={{-40,58},{-28,70}}))); +5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -12: Missing documentation. Affected line: AixLib.Utilities.Sources.PrescribedSolarRad varRad(n=6) annotation (Placement(transformation(extent={{70,60},{50,80}}))); +6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -13: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constSun[6](k=fill(0, 6)) annotation (Placement(transformation(extent={{100,70},{80,90}}))); +7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); -14: Missing documentation, Name 'sumHeatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat, Loads. Affected line: Modelica.Blocks.Sources.RealExpression sumHeatLoads(y=-sum(prescribedTemperature[:].port.Q_flow)) annotation (Placement(transformation(extent={{42,-72},{62,-52}}))); +8: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow2)); -15: Missing documentation, Name 'heatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Loads. Affected line: Modelica.Blocks.Sources.RealExpression heatLoads[nHeatedRooms](y=-(prescribedTemperature[:].port.Q_flow)) annotation (Placement(transformation(extent={{42,-92},{62,-72}}))); +9: Name 'withWindow3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window3. Affected line: parameter Boolean withWindow3=true "Window 3 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -16: Missing documentation, Name 'totalHeatLoad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: total, Heat, Load. Affected line: Modelica.Blocks.Interfaces.RealOutput totalHeatLoad annotation (Placement(transformation(extent={{88,-72},{108,-52}}))); +10: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow3)); -17: Missing documentation, Name 'roomHeatLoads' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heat, Loads. Affected line: Modelica.Blocks.Interfaces.RealOutput roomHeatLoads[nHeatedRooms] annotation (Placement(transformation(extent={{88,-92},{108,-72}}))); +11: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); -18: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=false, redeclare Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, initDynamicsAir=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, dis=1, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); +12: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); -19: Missing documentation, Name 'prescribedHeatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlowRad[nRooms] annotation (Placement(transformation(extent={{-60,-24},{-48,-12}}))); +13: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -20: Name 'adiabaticRadRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: adiabatic, Rooms. Affected line: Modelica.Blocks.Sources.Constant adiabaticRadRooms[nRooms](k=fill(0, nRooms)) "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-90,-26},{-74,-10}}))); +14: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -21: Missing documentation, Name 'fixedHeatFlowAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Attic. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlowAttic[1](Q_flow= {0}) annotation (Placement(transformation(extent={{-62,-34},{-52, -24}}))); +15: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +16: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-88,-24},{-78,32}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/RadConvToSingle.mo -1: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portCon annotation (Placement(transformation(extent={{-110,50},{-90,70}}))); +17: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, withWindow=withWindow2, withDoor=withDoor2, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={-25,58}, extent={{-6,-33},{6,33}}, rotation=270))); -2: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a portRad annotation (Placement(transformation(extent={{-110,-72},{ -90,-52}}))); +18: Missing documentation, Name 'inside_wall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={60,19}, extent={{-2,-15},{2,15}}, rotation=180))); +19: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={28,-60}, extent={{-4.00002,-26},{4.00001,26}}, rotation=90))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/BasicCharacteristic.mo -1: Missing documentation, Name 'T_Room;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: input Modelica.Units.SI.Temperature T_Room; +20: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.ceiling) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); -2: Missing documentation, Name 'q_Basis;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Basis. Affected line: output Modelica.Units.SI.HeatFlux q_Basis; +21: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor( final energyDynamics=energyDynamicsWalls, final solar_absorptance=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, wallPar=wallTypes.IW_hori_upp_half, outside=false, wall_length=room_length, wall_height=room_width_long, withWindow=false, withDoor=false, ISOrientation=AixLib.ThermalZones.HighOrder.Components.Types.InsideSurfaceOrientation.floor) if not use_UFH annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); +22: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO) annotation (Placement(transformation( origin={59,59}, extent={{-3.00001,-17},{3.00002,17}}, rotation=270))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow1IwL2IwS1Gr1Uf1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +23: Missing documentation, Name 'inside_wall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare final model WindowModel = WindowModel, final WindowType=Type_Win, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={60,-19}, extent={{-2,-15},{2,15}}, rotation=180))); -2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +24: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); -3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +25: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); -4: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +26: Missing documentation, Name 'thermInsideWall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1a annotation (Placement(transformation(extent={{80,0},{100,20}}))); -5: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); +27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-119.5,20},{-99.5,40}}), iconTransformation(extent={{-109.5,20},{-89.5,40}})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation (Placement( transformation( origin={44.5,101}, extent={{-10,-10},{10,10}}, rotation=270))); -6: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +28: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); -7: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +29: Missing documentation, Name 'thermInsideWall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); -8: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +30: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor annotation ( Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation( extent={{-16,-104},{4,-84}}))); -9: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +31: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement(transformation(extent={{-126,-74},{-99.5,-48}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); -10: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -11: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-60,-14},{-50,42}}))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeatingParameters.mo +1: Name 'thicknessPipe' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness, Pipe. Affected line: parameter Modelica.Units.SI.Thickness thicknessPipe "Thickness of pipe wall" annotation (Dialog(group="Panel Heating")); -12: Missing documentation, Name 'inside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={23,59}, extent={{-5.00018,-29},{5.00003,29}}, rotation=270))); +2: Name 'wallTypeFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Floor. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeFloor "Wall type for floor" annotation (Dialog(group="Room Specifications"), choicesAllMatching=true); -13: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,23}, extent={{-3,-15},{3,15}}, rotation=180))); +3: Name 'wallTypeCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: wall, Type, Ceiling. Affected line: replaceable parameter AixLib.DataBase.Walls.WallBaseDataDefinition wallTypeCeiling "Wall type for ceiling" annotation (Dialog(group="Room Specifications", enable = Ceiling), choicesAllMatching=true); -14: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={25,-59}, extent={{-5.00002,-29},{5.00001,29}}, rotation=90))); -15: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-31,60}, extent={{2,-9},{-2,9}}, rotation=90))); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeatingSystemParameters.mo +1: Name 'withSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Sheathing. Affected line: parameter Boolean withSheathing = false "=false if pipe has no Sheathing" annotation (Dialog(group = "Panel Heating"), choices(checkBox=true)); -16: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-27,-60}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); +2: Name 'thicknessSheathing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: thickness, Sheathing. Affected line: parameter Modelica.Units.SI.Thickness thicknessSheathing "Thickness of pipe sheathing" annotation (Dialog(enable=withSheathing, group="Panel Heating")); -17: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); +3: Name 'pipeMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: pipe, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.PipeMaterials.PipeMaterialDefinition pipeMaterial "Pipe Material" annotation (Dialog(group="Panel Heating"), choicesAllMatching=true); -18: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{34,-104},{54,-84}}))); +4: Name 'sheathingMaterial' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: sheathing, Material. Affected line: replaceable parameter AixLib.Fluid.HeatExchangers.ActiveWalls.UnderfloorHeating.BaseClasses.Sheathing_Materials.SheathingMaterialDefinition sheathingMaterial "Sheathing Material" annotation ( Dialog(group="Panel Heating", enable=withSheathing), choicesAllMatching=true); -19: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,20},{100,40}}))); +5: Name 'energyDynamicsWalls' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: energy, Dynamics, Walls. Affected line: parameter Modelica.Fluid.Types.Dynamics energyDynamicsWalls= Modelica.Fluid.Types.Dynamics.DynamicFreeInitial "Type of energy balance for wall capacities: dynamic (3 initialization options) or steady state" annotation(Evaluate=true, Dialog(tab="Dynamics")); -20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement( transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation( extent={{-109.5,-70},{-89.5,-50}}))); +6: Name 'raiseErrorForMaxVelocity' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: raise, Error, Velocity. Affected line: parameter Boolean raiseErrorForMaxVelocity = true "=true to raise error if v > v_max (0.5 m/s)" annotation(Dialog(tab="Advanced")); -21: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,50},{-89.5,70}}))); -22: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow1IwL2IwS1Lf1At1Ro1.mo +1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=2 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -23: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); +2: Documentation too short, Name 'room_width_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_long. Affected line: parameter Modelica.Units.SI.Length room_width_long=2 "w1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -24: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); +3: Documentation too short, Name 'room_width_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width_short. Affected line: parameter Modelica.Units.SI.Length room_width_short=2 "w2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -25: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{20,80},{40,100}}))); +4: Documentation too short, Name 'room_height_long' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_long. Affected line: parameter Modelica.Units.SI.Height room_height_long=2 "h1 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +5: Documentation too short, Name 'room_height_short' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height_short. Affected line: parameter Modelica.Units.SI.Height room_height_short=2 "h2 " annotation (Dialog(group="Dimensions", descriptionLabel=true)); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/DiscretizedFloorTemperatureAnalysis.mo -1: Name 'senTFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensor senTFloor[dis] "Temperature sensor for floor" annotation (Placement(transformation(extent={{-60,20},{-40,40}}))); +6: Documentation too short, Name 'roof_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof_width. Affected line: parameter Modelica.Units.SI.Length roof_width=2 "wRO" annotation (Dialog(group="Dimensions", descriptionLabel=true)); -2: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a[dis] annotation (Placement(transformation(extent={{-110,-10},{-90,10}}))); +7: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.25 "Solar absoptance roof " annotation (Dialog(group="Outer wall properties", descriptionLabel=true)); -3: Name 'TFloorMea' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMea(unit="K", displayUnit="degC") "Mean floor temperature" annotation (Placement(transformation(extent={{100,-50},{120,-30}}))); +8: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); -4: Name 'TFloorMin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMin(unit="K", displayUnit="degC") "Minimal floor temperature" annotation (Placement(transformation(extent={{100,-10},{120,10}}))); +9: Name 'windowarea_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O. Affected line: parameter Modelica.Units.SI.Area windowarea_RO=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=if withWindow3 then true else false)); -5: Name 'TFloorMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMax(unit="K", displayUnit="degC") "Maximum floor temperature" annotation (Placement(transformation(extent={{100,30},{120,50}}))); +10: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, wall_length=room_length, wall_height=room_height_short, withWindow=false, windowarea=0, withDoor=false, door_height=0, door_width=0) annotation (Placement(transformation(extent={{-60,-12},{-50,46}}))); +11: Missing documentation, Name 'inner_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inner_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inner_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={-14,58}, extent={{-3.99997,-22},{3.99999,22}}, rotation=270))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/TablesAndParameters/Tables/CombiTable1DParameter.mo -1: Missing documentation, Name 'tableID;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: input Modelica.Blocks.Types.ExternalCombiTable1D tableID; +12: Missing documentation, Name 'inside_wall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,19}, extent={{-3,-15},{3,15}}, rotation=180))); -2: Missing documentation, Name 'icol;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: icol. Affected line: input Integer icol; +13: Missing documentation, Name 'inside_wall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall3. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall3( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width_long, wall_height=0.5*(room_height_long + room_height_short + room_width_short/ room_width_long*(room_height_long - room_height_short)), withWindow=false, withDoor=false) annotation (Placement(transformation( origin={20,-60}, extent={{-4,-24},{4,24}}, rotation=90))); -3: Missing documentation. Affected line: input Real u; +14: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_hori_att_low_half, outside=false, wall_length=room_length, wall_height=room_width_short, withWindow=false, withDoor=false, ISOrientation=3) annotation (Placement(transformation( origin={28,60}, extent={{1.99999,-10},{-1.99998,10}}, rotation=90))); -4: Name 'tableAvailable' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, Available. Affected line: input Real tableAvailable "Dummy input to ensure correct sorting of function calls"; +15: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width_long, each withWindow=false, each withDoor=false, each ISOrientation=2) annotation (Placement(transformation( origin={-24,-60}, extent={{-1.99999,-10},{1.99999,10}}, rotation=90))); -5: Missing documentation. Affected line: output Real y; +16: Missing documentation, Name 'inside_wall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall2b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height_long, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-20}, extent={{-2.99998,-16},{2.99998,16}}, rotation=180))); -6: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: external"C" y = ModelicaStandardTables_CombiTable1D_getValue(tableID, icol, u) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});annotation (derivative(noDerivative=tableAvailable) = getDerTableValue);end getTableValue; +17: Missing documentation, Name 'roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: roof. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall roof( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_RO, final wallPar=wallTypes.roofRoomUpFloor, wall_length=room_length, withDoor=false, door_height=0, door_width=0, wall_height=roof_width, withWindow=withWindow3, windowarea=windowarea_RO, ISOrientation=1) annotation (Placement(transformation( origin={58,59}, extent={{-2.99997,-16},{2.99999,16}}, rotation=270))); -7: Name 'getDerTableValue' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Table, Value. Affected line: function getDerTableValue "Derivative of interpolated 1-dim. table defined by matrix" extends Modelica.Icons.Function; +18: Missing documentation, Name 'thermInsideWall3' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall3. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall3 annotation (Placement(transformation(extent={{20,-100},{40,-80}}), iconTransformation(extent={{20,-100},{40,-80}}))); -8: Missing documentation, Name 'der_u;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_u. Affected line: input Real der_u; +19: Missing documentation, Name 'thermInsideWall2a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2a annotation (Placement(transformation(extent={{80,0},{100,20}}))); -9: Missing documentation, Name 'der_y;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: der_y. Affected line: output Real der_y; +20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-60},{-89.5,-40}}))); -10: Documentation too short, Name 'external' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: external. Affected line: external"C" der_y = ModelicaStandardTables_CombiTable1D_getDerValue(tableID, icol, u, der_u) annotation (Library={"ModelicaStandardTables", "ModelicaMatIO", "zlib"});end getDerTableValue; +21: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); -11: Name 'table' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table. Affected line: parameter Real table[:, :] "Table matrix (grid = first column; e.g., table=[0,2])" annotation (Dialog(group="Table data definition",enable=not tableOnFile)); +22: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling annotation (Placement(transformation(extent={{80,40},{100,60}}))); -12: Name 'columns' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: columns. Affected line: final parameter Integer columns[:]=2:size(table, 2) "Columns of table to be interpolated" annotation (Dialog(group="Table data interpretation")); +23: Missing documentation, Name 'thermFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Floor. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermFloor[dis] annotation (Placement(transformation(extent={{-16,-104},{4,-84}}), iconTransformation(extent={{-16,-104},{4,-84}}))); -13: Name 'tableID' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: table, D. Affected line: final parameter Modelica.Blocks.Types.ExternalCombiTable1D tableID= Modelica.Blocks.Types.ExternalCombiTable1D( "NoName", "NoName", table, columns, Modelica.Blocks.Types.Smoothness.LinearSegments) "External table object"; +24: Missing documentation, Name 'SolarRadiationPort_Roof' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, Roof. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_Roof annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=270, origin={74,100}))); -14: Missing documentation. Affected line: final parameter Integer n= 1; +25: Missing documentation, Name 'thermInsideWall2b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall2b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2b annotation (Placement(transformation(extent={{80,-40},{100,-20}}))); -15: Missing documentation. Affected line: parameter Real u; +26: Missing documentation, Name 'thermInsideWall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1 annotation (Placement(transformation(extent={{-20,80},{0,100}}), iconTransformation(extent={{-20,80},{0,100}}))); -16: Missing documentation. Affected line: final parameter Real y = getTableValue(tableID, n, u, 1.0); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/DiscretizedFloorTemperatureAnalysis.mo +1: Name 'senTFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Thermal.HeatTransfer.Sensors.TemperatureSensor senTFloor[dis] "Temperature sensor for floor" annotation (Placement(transformation(extent={{-60,20},{-40,40}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo -1: Name 'portsCirSup' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_b portsCirSup[n](redeclare each final package Medium = Medium) "Supply ports to circuits" annotation (Placement( visible=true, transformation( origin={0,60}, extent={{-10,-40},{10,40}}, rotation=90), iconTransformation( origin={-8,60}, extent={{-6,-24},{6,24}}, rotation=90))); +2: Missing documentation. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a port_a[dis] annotation (Placement(transformation(extent={{-110,-10},{-90,10}}))); -2: Name 'portsCirRet' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_a portsCirRet[n](redeclare each final package Medium = Medium) "Return ports from circuits" annotation ( Placement( visible=true, transformation( origin={0,-60}, extent={{-10,-40},{10,40}}, rotation=90), iconTransformation( origin={8,-62}, extent={{-6,-24},{6,24}}, rotation=90))); +3: Name 'TFloorMea' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMea(unit="K", displayUnit="degC") "Mean floor temperature" annotation (Placement(transformation(extent={{100,-50},{120,-30}}))); -3: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); +4: Name 'TFloorMin' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMin(unit="K", displayUnit="degC") "Minimal floor temperature" annotation (Placement(transformation(extent={{100,-10},{120,10}}))); -4: Name 'rho_default' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: rho_default. Affected line: parameter Modelica.Units.SI.Density rho_default=Medium.density(sta_default) "Density, used to compute fluid volume"; +5: Name 'TFloorMax' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: Modelica.Blocks.Interfaces.RealOutput TFloorMax(unit="K", displayUnit="degC") "Maximum floor temperature" annotation (Placement(transformation(extent={{100,30},{120,50}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH_WODis.mo +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH.mo 1: Missing documentation, Name 'nZones' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Zones. Affected line: parameter Integer nZones = 11; 2: Missing documentation, Name 'nHeatedRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Heated, Rooms. Affected line: parameter Integer nHeatedRooms = 10; -3: Missing documentation. Affected line: parameter Integer dis=1; +3: Missing documentation. Affected line: parameter Integer dis=10; 4: Missing documentation, Name 'Spacing' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Spacing. Affected line: parameter Modelica.Units.SI.Distance Spacing[nHeatedRooms] = fill(0.2, 10); @@ -1798,7 +1774,7 @@ AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH_W 9: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constAmb(k=261.15) annotation (Placement(transformation(extent={{-70,70},{-50,90}}))); -10: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow groundTemp[5](Q_flow= fill(0, 5)) annotation (Placement(transformation(extent={{-6,-6},{6,6}}, rotation=180, origin={64,-70}))); +10: Missing documentation, Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow groundTemp[5](Q_flow= fill(0, 5)) annotation (Placement(transformation(extent={{-54,-96},{-42,-84}}))); 11: Missing documentation, Name 'heatStarToComb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heat, Star, Comb. Affected line: AixLib.Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToComb[nZones] annotation (Placement(transformation( extent={{8,-6},{-8,6}}, rotation=0, origin={-36,-12}))); @@ -1808,7 +1784,7 @@ AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH_W 14: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant constSun[6](k=fill(0, 6)) annotation (Placement(transformation(extent={{100,70},{80,90}}))); -15: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=true, redeclare BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); +15: Missing documentation, Name 'wholeHouseBuildingEnvelope' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: whole, House, Building, Envelope. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelopeDiscretized.WholeHouseBuildingEnvelope wholeHouseBuildingEnvelope( use_UFH=true, redeclare BaseClasses.FloorLayers.EnEV2009Heavy_UFH wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, calcMethodIn=1, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare AixLib.DataBase.WindowsDoors.Simple.WindowSimple_EnEV2009 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, dis=dis, AirExchangeCorridor=0, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{-14,-10},{42,46}}))); 16: Missing documentation, Name 'prescribedHeatFlowRad' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: prescribed, Heat. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlow prescribedHeatFlowRad[nZones] annotation (Placement(transformation(extent={{-60,-16}, {-48,-4}}))); @@ -1816,91 +1792,115 @@ AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/Examples/OFD/OFD_UFH_W 18: Missing documentation, Name 'fixedHeatFlowAttic' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: fixed, Heat, Attic. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedHeatFlow fixedHeatFlowAttic[1](Q_flow={0}) annotation (Placement(transformation(extent={{-62,-26}, {-52,-16}}))); -19: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = AixLib.Media.Water, nZones=10, dis=dis, Q_flow_nominal={638,1078,502,341,783,766,506,196,443,658}, A={ wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.room_width, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.room_length*wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.room_width, wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Children1.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Children1.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Bath.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Bath.room_width_long, wholeHouseBuildingEnvelope.upperFloor_Building.Children2.room_length*wholeHouseBuildingEnvelope.upperFloor_Building.Children2.room_width_long}, calculateVol=2, wallTypeFloor=fill( BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH(), 10), Ceiling={false,false,false,false,false,true,true,true,true,true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.wallTypes.IW_hori_low_half, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.wallTypes.IW_hori_low_half}, TZoneBel_nominal={293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15}, Spacing=fill(0.2, 10), pipeMaterial=BaseClasses.PipeMaterials.PERTpipe(), thicknessPipe=fill(0.002, 10), dOut=fill(0.017, 10), withSheathing=false, ufhRoom(TSup_nominal(displayUnit="K") = 308.15, TRet_nominal( displayUnit="K") = 303.15)) annotation (Placement(transformation(extent={{-68,-66},{-50,-50}}))); +19: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: UnderfloorHeating.UnderfloorHeatingSystem underfloorHeatingSystem( redeclare package Medium = AixLib.Media.Water, nZones=10, dis=dis, Q_flow_nominal={638,1078,502,341,783,766,506,196,443,658}, A={wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.AFloor, wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Bedroom.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Children1.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Corridor.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Bath.AFloor, wholeHouseBuildingEnvelope.upperFloor_Building.Children2.AFloor}, calculateVol=2, wallTypeFloor=fill( BaseClasses.FloorLayers.FLpartition_EnEV2009_SM_upHalf_UFH(), 10), Ceiling={false,false,false,false,false,true,true,true,true,true}, wallTypeCeiling={ UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), UnderfloorHeating.BaseClasses.FloorLayers.Ceiling_Dummy(), wholeHouseBuildingEnvelope.groundFloor_Building.Livingroom.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Hobby.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Corridor.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.WC_Storage.Ceiling[ 1].Wall.wallType,wholeHouseBuildingEnvelope.groundFloor_Building.Kitchen.Ceiling[ 1].Wall.wallType}, TZoneBel_nominal={293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15,293.15, 293.15}, Spacing=fill(0.2, 10), pipeMaterial=BaseClasses.PipeMaterials.PERTpipe(), thicknessPipe=fill(0.002, 10), dOut=fill(0.017, 10), withSheathing=false) annotation (Placement(transformation(extent={{-68,-66},{-44,-52}}))); 20: Missing documentation, Name 'm_flow_specification1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: m_flow_specification. Affected line: AixLib.Fluid.Sources.MassFlowSource_T m_flow_specification1( redeclare package Medium = AixLib.Media.Water, m_flow=underfloorHeatingSystem.m_flow_nominal, T=underfloorHeatingSystem.T_Vdes, nPorts=1) annotation (Placement(transformation(extent={{-98,-66},{-82,-50}}))); 21: Missing documentation, Name 'boundary' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: boundary. Affected line: AixLib.Fluid.Sources.Boundary_pT boundary(redeclare package Medium = AixLib.Media.Water, nPorts=1) annotation (Placement(transformation(extent={{-12,-64},{-24,-52}}))); -22: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[underfloorHeatingSystem.nZones](each k =1) annotation (Placement(transformation( extent={{-6,-6},{6,6}}, rotation=0, origin={-86,-36}))); +22: Missing documentation. Affected line: Modelica.Blocks.Sources.Constant const[sum(underfloorHeatingSystem.ufhRoom.nCircuits)](each k=1) annotation (Placement(transformation( extent={{-6,-6},{6,6}}, rotation=0, origin={-86,-36}))); -AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelopeDiscretized/Rooms/Ow2IwL2IwS1Gr1Uf1.mo -1: Name 'room_lengthb' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_lengthb. Affected line: parameter Modelica.Units.SI.Length room_lengthb=1 "length_b " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +AixLib/Systems/BuildingEnergySystem/BuildingEnergySystem.mo +1: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: BoundaryConditions.WeatherData.Old.WeatherTRY.Weather Weather( Latitude=49.5, Longitude=8.5, GroundReflection=0.2, tableName="wetter", extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, SOD=AixLib.DataBase.Weather.SurfaceOrientation.SurfaceOrientationData_N_E_S_W_RoofN_Roof_S(), Wind_dir=false, Wind_speed=true, Air_temp=true, fileName="modelica://AixLib/Resources/WeatherData/TRY2010_12_Jahr_Modelica-Library.txt", WeatherData(tableOnFile=false, table=weatherDataDay.weatherData)) annotation (Placement(transformation(extent={{340,156},{268,204}})));ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.WholeHouseBuildingEnvelope OFD( redeclare DataBase.Walls.Collections.OFD.WSchV1995Heavy wallTypes, energyDynamicsWalls=Modelica.Fluid.Types.Dynamics.FixedInitial, energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial, T0_air=294.15, TWalls_start=292.15, redeclare model WindowModel = ThermalZones.HighOrder.Components.WindowsDoors.WindowSimple, redeclare DataBase.WindowsDoors.Simple.WindowSimple_WSchV1995 Type_Win, redeclare model CorrSolarGainWin = ThermalZones.HighOrder.Components.WindowsDoors.BaseClasses.CorrectionSolarGain.CorGSimple, use_infiltEN12831=true, n50=if TIR == 1 or TIR == 2 then 3 else if TIR == 3 then 4 else 6, withDynamicVentilation=true, UValOutDoors=if TIR == 1 then 1.8 else 2.9) annotation (Placement(transformation(extent={{200,-58}, {334,86}}))); -2: Name 'room_width' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_width. Affected line: parameter Modelica.Units.SI.Length room_width=2 "width " annotation (Dialog(group="Dimensions", descriptionLabel=true)); +2: Missing documentation, Name 'tempOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Outside. Affected line: Modelica.Thermal.HeatTransfer.Sources.PrescribedTemperature tempOutside annotation (Placement(transformation(extent={{10.375,-10.375},{-10.375,10.375}}, rotation=90, origin={189.625,129.625}))); -3: Name 'room_height' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: room_height. Affected line: parameter Modelica.Units.SI.Height room_height=2 "height" annotation (Dialog(group="Dimensions", descriptionLabel=true)); +3: Documentation too short, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: HeatPumpSystems.HeatPumpSystem heatPumpSystem( redeclare package Medium_con = Medium_sin, redeclare package Medium_eva = Medium_sou, dataTable=AixLib.DataBase.HeatPump.EN255.Vitocal350BWH113(), use_deFro=false, massDynamics=Modelica.Fluid.Types.Dynamics.DynamicFreeInitial, energyDynamics=Modelica.Fluid.Types.Dynamics.FixedInitial, refIneFre_constant=0.01, dpEva_nominal=0, deltaM_con=0.1, use_opeEnvFroRec=true, tableUpp=[-100,100; 100,100], minIceFac=0, use_chiller=true, calcPel_deFro=100, minRunTime(displayUnit="min"), minLocTime(displayUnit="min"), use_antLeg=false, use_refIne=true, initType=Modelica.Blocks.Types.Init.InitialOutput, minTimeAntLeg(displayUnit="min") = 900, scalingFactor=1, use_tableData=false, dpCon_nominal=0, use_conCap=true, CCon=3000, use_evaCap=true, CEva=3000, Q_flow_nominal=5000, cpEva=4180, cpCon=4180, use_secHeaGen=false, redeclare model TSetToNSet = Controls.HeatPump.BaseClasses.OnOffHP (hys=5), use_sec=true, QCon_nominal=10000, P_el_nominal=2500, redeclare model PerDataHea = AixLib.DataBase.HeatPump.PerformanceData.LookUpTable2D ( smoothness=Modelica.Blocks.Types.Smoothness.LinearSegments, dataTable= AixLib.DataBase.HeatPump.EN255.Vitocal350BWH113( tableP_ele=[0,-5.0,0.0,5.0,10.0,15.0; 35,3750,3750,3750,3750,3833;45,4833,4917,4958,5042,5125; 55,5583,5667,5750,5833,5958; 65,7000, 7125,7250,7417,7583]), printAsserts=false, extrapolation=false), redeclare function HeatingCurveFunction = Controls.SetPoints.Functions.HeatingCurveFunction (TDesign=328.15), use_minRunTime=true, use_minLocTime=true, use_runPerHou=true, pre_n_start=true, redeclare Fluid.Movers.Data.Pumps.Wilo.Stratos80slash1to12 perEva, redeclare Fluid.Movers.Data.Pumps.Wilo.Stratos25slash1to4 perCon, TCon_nominal=313.15, TCon_start=313.15, TEva_start=283.15, use_revHP=false, VCon=0.004, VEva=0.004) annotation (Placement(transformation(extent={{-280,-46},{-214,46}}))); -4: Name 'AFloor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Floor. Affected line: parameter Modelica.Units.SI.Area AFloor=4 "Floor Area" annotation (Dialog(group="Dimensions")); +4: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Fluid.Storage.BufferStorage bufferStorage( redeclare package Medium = Medium, useHeatingCoil1=false, useHeatingCoil2=false, useHeatingRod=false, n=5, hConIn=100, hConOut=10, redeclare final model HeatTransfer = AixLib.Fluid.Storage.BaseClasses.HeatTransferBuoyancyWetter) annotation (Placement(transformation(extent={{-106,-30},{-74,10}}))); -5: Name 'windowarea_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW1=0 "Window area " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withWindow1)); +5: Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Fluid.Sources.Boundary_pT sin( nPorts=1, redeclare package Medium = Medium_sou, p=200000, T=281.15) "Fluid sink on source side" annotation (Placement(transformation(extent={{-322,-64},{-302,-44}})));Fluid.Sources.Boundary_pT sou( use_T_in=true, nPorts=1, redeclare package Medium = Medium_sou) "Fluid source on source side" annotation (Placement(transformation(extent={{-172,-62},{-192,-42}}))); -6: Name 'withWindow2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Window. Affected line: parameter Boolean withWindow2=true "Window 2 " annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +6: Missing documentation, Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = Modelica.Media.Interfaces.PartialMedium annotation (choicesAllMatching=true); -7: Name 'windowarea_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: windowarea_, O, W. Affected line: parameter Modelica.Units.SI.Area windowarea_OW2=0 "Window area" annotation ( Dialog( group="Windows and Doors", naturalWidth=10, descriptionLabel=true, enable=withWindow2)); +7: Missing documentation, Name 'tempOutside1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Outside. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature tempOutside1(T=290.15) annotation (Placement(transformation(extent={{10.375,-10.375},{-10.375,10.375}}, rotation=180, origin={-100.375,-96.375}))); -8: Name 'withDoor1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor1=true "Door 1" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +8: Missing documentation, Name 'tempGround' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: temp, Ground. Affected line: Modelica.Thermal.HeatTransfer.Sources.FixedTemperature tempGround[5](T=282.65) annotation (Placement(transformation( extent={{10.375,-10.375},{-10.375,10.375}}, rotation=180, origin={231.625,-86.375}))); -9: Name 'door_width_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD1=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +9: Missing documentation, Name 'NaturalVentilation' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Natural, Ventilation. Affected line: Modelica.Blocks.Sources.CombiTimeTable NaturalVentilation( columns={2,3,4,5,7}, extrapolation=Modelica.Blocks.Types.Extrapolation.Periodic, tableOnFile=false, table=VentilationProfile.Profile) annotation(Placement(transformation(extent={{10,10}, {-10,-10}}, rotation=180, origin={151,51}))); -10: Name 'door_height_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD1=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); -11: Name 'withDoor2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: with, Door. Affected line: parameter Boolean withDoor2=true "Door 2" annotation (Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true), choices(checkBox=true)); +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/EN1264/BasicCharacteristic.mo +1: Missing documentation, Name 'T_Room;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: T_. Affected line: input Modelica.Units.SI.Temperature T_Room; -12: Name 'door_width_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_width_, O, D. Affected line: parameter Modelica.Units.SI.Length door_width_OD2=0 "width " annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +2: Missing documentation, Name 'q_Basis;' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: q_, Basis. Affected line: output Modelica.Units.SI.HeatFlux q_Basis; -13: Name 'door_height_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: door_height_, O, D. Affected line: parameter Modelica.Units.SI.Length door_height_OD2=0 "height " annotation ( Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); -14: Name 'U_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD1=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor1)); +AixLib/ThermalZones/HighOrder/House/OFD_MiddleInnerLoadWall/BuildingEnvelope/WholeHouseBuildingEnvelope.mo +1: Name 'Medium' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Medium. Affected line: replaceable package Medium = AixLib.Media.Air constrainedby Modelica.Media.Interfaces.PartialMedium "Medium in the component" annotation (choices( choice(redeclare package MediumR = AixLib.Media.Air "Moist air"), choice(redeclare package MediumR = AixLib.Media.Air (extraPropertiesNames={"CO2"}, C_nominal = {6.12E-4}) "Moist air with tracer gas (404 ppm CO2)"))); -15: Documentation too short, Name 'eps_door_OD1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD1=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor1)); +2: Name 'AirExchangeCorridor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor. Affected line: parameter Real AirExchangeCorridor=2 "Air exchange corridors in 1/h " annotation (Dialog(group="Air Exchange Corridors", descriptionLabel=true)); -16: Name 'U_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: U_door_, O, D. Affected line: parameter Real U_door_OD2=2.5 "U-value" annotation ( Dialog( group="Windows and Doors", joinNext=true, descriptionLabel=true, enable=withDoor2)); +3: Name 'solar_absorptance_RO' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: solar_absorptance_, O. Affected line: parameter Real solar_absorptance_RO=0.1 "Solar absoptance roof " annotation (Dialog(tab="Outer walls", group="Solar absorptance", descriptionLabel=true)); -17: Documentation too short, Name 'eps_door_OD2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: eps_door_, O, D. Affected line: parameter Real eps_door_OD2=0.95 "eps" annotation (Dialog( group="Windows and Doors", descriptionLabel=true, enable=withDoor2)); +4: Name 'UValOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.CoefficientOfHeatTransfer UValOutDoors=2.5 "U-value (thermal transmittance) of doors in outer walls" annotation (Dialog(tab="Outer walls", group="Doors")); -18: Missing documentation, Name 'outside_wall1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall1( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW1, door_height=door_height_OD1, door_width=door_width_OD1, wall_length=room_length, wall_height=room_height, withWindow=withWindow1, withDoor=withDoor1, U_door=U_door_OD1, eps_door=eps_door_OD1) annotation (Placement(transformation(extent={{-58,-16},{-48,42}}))); +5: Name 'epsOutDoors' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Doors. Affected line: parameter Modelica.Units.SI.Emissivity epsOutDoors( min=0, max=1) = 0.95 "Emissivity of inside surface of outer doors" annotation (Dialog(tab="Outer walls", group="Doors")); -19: Missing documentation, Name 'outside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: outside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall outside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.OW, windowarea=windowarea_OW2, door_height=door_height_OD2, door_width=door_width_OD2, wall_length=room_width, wall_height=room_height, withWindow=withWindow2, withDoor=withDoor2, U_door=U_door_OD2, eps_door=eps_door_OD2) annotation (Placement(transformation( origin={23,57}, extent={{-4.99998,-27},{5.00001,27}}, rotation=270))); +6: Name 'TDynVentHobby_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Hobby_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentHobby_set=295.15 "Hobby set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -20: Missing documentation, Name 'inside_wall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1a. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1a( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_length - room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,22}, extent={{-2.99999,-16},{2.99999,16}}, rotation=180))); +7: Name 'TDynVentCorridorGF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, G, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorGF_set=291.15 "Corridor (GF) set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -21: Missing documentation, Name 'inside_wall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall2( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW_vert_half_a, outside=false, wall_length=room_width, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={22,-62}, extent={{-4.00002,-26},{4.00001,26}}, rotation=90))); +8: Name 'TDynVentWCStorage_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, W, Storage_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentWCStorage_set=291.15 "WC / Storage room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -22: Missing documentation, Name 'Ceiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Ceiling. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall Ceiling[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.IW_hori_low_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=3) annotation (Placement(transformation( origin={-30,59}, extent={{2.99997,-16},{-3.00002,16}}, rotation=90))); +9: Name 'TDynVentKitchen_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Kitchen_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentKitchen_set=295.15 "Kitchen set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -23: Missing documentation, Name 'floor' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: floor. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall floor[dis]( each final energyDynamics=energyDynamicsWalls, each final calcMethodOut=calcMethodOut, each final hConOut_const=hConOut_const, each final surfaceType=surfaceType, each final calcMethodIn=calcMethodIn, each final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, each final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, each final T0=TWalls_start, each final withSunblind=use_sunblind, each final Blinding=1 - ratioSunblind, each final LimitSolIrr=solIrrThreshold, each final TOutAirLimit=TOutAirLimit, each final solar_absorptance=solar_absorptance_OW, each final wallPar=wallTypes.groundPlate_upp_half, each outside=false, each wall_length=room_length/dis, each wall_height=room_width, each withWindow=false, each withDoor=false, each ISOrientation=2) if not use_UFH annotation (Placement(transformation( origin={-27,-62}, extent={{-2.00002,-11},{2.00001,11}}, rotation=90))); +10: Name 'TDynVentBedroom_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bedroom_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBedroom_set=295.15 "Bedroom set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -24: Missing documentation, Name 'inside_wall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: inside_wall1b. Affected line: AixLib.ThermalZones.HighOrder.Components.Walls.Wall inside_wall1b( final energyDynamics=energyDynamicsWalls, final calcMethodOut=calcMethodOut, final hConOut_const=hConOut_const, final surfaceType=surfaceType, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, redeclare model WindowModel = WindowModel, final WindowType=Type_Win, redeclare model CorrSolarGainWin = CorrSolarGainWin, final T0=TWalls_start, final withSunblind=use_sunblind, final Blinding=1 - ratioSunblind, final LimitSolIrr=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final solar_absorptance=solar_absorptance_OW, final wallPar=wallTypes.IW2_vert_half_a, outside=false, wall_length=room_lengthb, wall_height=room_height, withWindow=false, withDoor=false) annotation (Placement(transformation( origin={61,-17}, extent={{-3,-15},{3,15}}, rotation=180))); +11: Name 'TDynVentChildren1_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children1_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren1_set=295.15 "Children 1 room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -25: Missing documentation, Name 'thermInsideWall2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall2 annotation (Placement(transformation(extent={{20,-100},{40,-80}}))); +12: Name 'TDynVentCorridorUF_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Corridor, F_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentCorridorUF_set=291.15 "Corridor (UF) set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -26: Missing documentation, Name 'thermInsideWall1a' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1a. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1a annotation (Placement(transformation(extent={{80,20},{100,40}}))); +13: Name 'TDynVentBath_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Bath_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentBath_set=297.15 "Bathroom set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -27: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == 1 or calcMethodOut == 2) annotation (Placement(transformation(extent={{-119.5,-70},{-99.5,-50}}), iconTransformation(extent={{-109.5,-50},{-89.5,-30}}))); +14: Name 'TDynVentChildren2_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Children2_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentChildren2_set=295.15 "Children 2 room set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -28: Missing documentation, Name 'SolarRadiationPort_OW1' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW1 annotation (Placement(transformation(extent={{-109.5,20},{-89.5,40}}))); +15: Name 'TDynVentAttic_set' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Attic_set. Affected line: parameter Modelica.Units.SI.Temperature TDynVentAttic_set=288.15 "Attic set temperature for dyn. vent." annotation (Dialog(tab= "Dynamic ventilation", enable=withDynamicVentilation)); -29: Missing documentation, Name 'SolarRadiationPort_OW2' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Solar, Radiation, Port_, O, W. Affected line: AixLib.Utilities.Interfaces.SolarRad_in SolarRadiationPort_OW2 annotation ( Placement(transformation( origin={50.5,101}, extent={{-10,-10},{10,10}}, rotation=270), iconTransformation( extent={{-10,-10},{10,10}}, rotation=270, origin={50.5,99}))); +16: Name 'useVentAirPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent, Port. Affected line: parameter Boolean useVentAirPort = false "Use air port for ventialtion" annotation (Dialog(tab= "Dynamic ventilation")); -30: Missing documentation, Name 'thermCeiling' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Ceiling. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermCeiling[dis] annotation (Placement(transformation(extent={{80,60},{100,80}}))); +17: Missing documentation, Name 'groundFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.GroundFloorBuildingEnvelope groundFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, redeclare package Medium = Medium, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final Tset_Livingroom=TDynVentLivingroom_set, final Tset_Hobby=TDynVentHobby_set, final Tset_Corridor=TDynVentCorridorGF_set, final Tset_WC=TDynVentWCStorage_set, final Tset_Kitchen=TDynVentKitchen_set, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-20,-74},{20,-26}}))); -31: Missing documentation, Name 'thermInsideWall1b' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Inside, Wall1b. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermInsideWall1b annotation (Placement(transformation(extent={{80,-20},{100,0}}))); +18: Missing documentation, Name 'upperFloor_Building' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: upper, Floor_, Building. Affected line: AixLib.ThermalZones.HighOrder.House.OFD_MiddleInnerLoadWall.BuildingEnvelope.UpperFloorBuildingEnvelope upperFloor_Building( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final withDynamicVentilation=withDynamicVentilation, redeclare package Medium = Medium, final solar_absorptance_RO=solar_absorptance_RO, final Tset_Bedroom=TDynVentBedroom_set, final Tset_Children1=TDynVentChildren1_set, final Tset_Corridor=TDynVentCorridorUF_set, final Tset_Bath=TDynVentBath_set, final Tset_Children2=TDynVentChildren2_set, final UValOutDoors=UValOutDoors, final epsOutDoors=epsOutDoors, final use_UFH=use_UFH) annotation (Placement(transformation(extent={{-26,-12}, {20,34}}))); -32: Missing documentation, Name 'ground' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a ground[dis] if not use_UFH annotation (Placement(transformation(extent={{-16,-104},{4,-84}}))); +19: Missing documentation, Name 'attic_2Ro_5Rooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: attic_, Ro_5, Rooms. Affected line: AixLib.ThermalZones.HighOrder.Rooms.OFD.Attic_Ro2Lf5 attic_2Ro_5Rooms( final denAir=denAir, final cAir=cAir, final wallTypes=wallTypes, final energyDynamicsWalls=energyDynamicsWalls, final energyDynamics=energyDynamics, final T0_air=T0_air, final TWalls_start=TWalls_start, final calcMethodIn=calcMethodIn, final hConIn_const=hConIn_const, final radLongCalcMethod=radLongCalcMethod, final T_ref=T_ref, final Type_Win=Type_Win, redeclare final model WindowModel = WindowModel, redeclare final model CorrSolarGainWin = CorrSolarGainWin, final solar_absorptance_OW=solar_absorptance_OW, final calcMethodOut=calcMethodOut, final surfaceType=surfaceType, final hConOut_const=hConOut_const, final use_infiltEN12831=use_infiltEN12831, final n50=n50, final e=e, final eps=eps, final use_sunblind=use_sunblind, final ratioSunblind=ratioSunblind, final solIrrThreshold=solIrrThreshold, final TOutAirLimit=TOutAirLimit, final withDynamicVentilation=withDynamicVentilation, final HeatingLimit=HeatingLimit, final Max_VR=Max_VR, final Diff_toTempset=Diff_toTempset, final Tset=TDynVentAttic_set, final solar_absorptance_RO=solar_absorptance_RO, length=10.64, width=4.75, roof_width1=3.36, roof_width2=3.36, room1_length=5.875, room2_length=3.215, room3_length=3.92, room4_length=3.215, room5_length=4.62, room1_width=2.28, room2_width=2.28, room3_width=2.28, room4_width=2.28, room5_width=2.28, nPorts=2, alfa=1.5707963267949, replaceable package Medium = Medium) annotation (Placement(transformation(extent={{-22,44},{22,82}}))); +20: Missing documentation, Name 'WindSpeedPort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Wind, Speed, Port. Affected line: Modelica.Blocks.Interfaces.RealInput WindSpeedPort if (calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.DIN_6946 or calcMethodOut == AixLib.ThermalZones.HighOrder.Components.Types.CalcMethodConvectiveHeatTransfer.ASHRAE_Fundamentals) annotation (Placement( transformation(extent={{-128,66},{-100,94}}),iconTransformation(extent={{-120,60},{-100,80}}))); -AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/PartialUnderFloorHeating.mo -1: Name 'v' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: v. Affected line: final parameter Modelica.Units.SI.Velocity v=V_flow_nominal/(Modelica.Constants.pi/4*dInn^(2)) "velocity of medium in pipe"; +21: Name 'AirExchangePort' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Port. Affected line: Modelica.Blocks.Interfaces.RealInput AirExchangePort[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-128,42},{-100,70}}), iconTransformation(extent={{-120,40},{-100,60}}))); -2: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); +22: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofS annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,64}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,64})));Utilities.Interfaces.SolarRad_in SolarRadiationPort_RoofN annotation ( Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,90})));Utilities.Interfaces.SolarRad_in North annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,38}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,38})));Utilities.Interfaces.SolarRad_in East annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,12}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,12})));Utilities.Interfaces.SolarRad_in South annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-14}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-14})));Utilities.Interfaces.SolarRad_in West annotation (Placement(transformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-38}), iconTransformation( extent={{-10,-10},{10,10}}, rotation=180, origin={106,-38}))); -3: Name 'rho_default' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: rho_default. Affected line: parameter Modelica.Units.SI.Density rho_default=Medium.density(sta_default) "Density, used to compute fluid volume"; +23: Missing documentation, Name 'varAirExchange' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange. Affected line: AixLib.ThermalZones.HighOrder.Components.DryAir.VarAirExchange varAirExchange( final V=0.5*(upperFloor_Building.Corridor.airload.V + groundFloor_Building.Corridor.airload.V), final c=cAir, final rho=denAir) annotation (Placement( transformation( extent={{-5,5},{5,-5}}, rotation=270, origin={39,-21}))); + +24: Missing documentation, Name 'AirExchangeCorridor_Source' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Exchange, Corridor_, Source. Affected line: Modelica.Blocks.Sources.Constant AirExchangeCorridor_Source(final k=AirExchangeCorridor) annotation (Placement(transformation(extent={{56,-16},{50,-10}}))); + +25: Name 'heatingToRooms' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: heating, Rooms. Affected line: AixLib.Utilities.Interfaces.ConvRadComb heatingToRooms[11] "1: LivingRoom_GF, 2: Hobby_GF, 3: Corridor_GF, 4: WC_Storage_GF, 5: Kitchen_GF, 6: Bedroom_UF, 7: Child1_UF, 8: Corridor_UF, 9: Bath_UF, 10: Child2_UF, 11: Attic" annotation (Placement(transformation(extent={{-112,-30},{-92,-10}}), iconTransformation(extent={{-110,-38},{-90,-18}}))); + +26: Name 'groundTemp' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ground, Temp. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a groundTemp[5] if not use_UFH "HeatPorts to force ground temperature(s) for the ground floor." annotation (Placement(transformation(extent={{-10,-110},{10,-90}}), iconTransformation(extent={{-10,-110},{10,-90}}))); + +27: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: Components.Walls.BaseClasses.SimpleNLayer groPlateLowPart[5]( final A={groundFloor_Building.Livingroom.floor.Wall.A,groundFloor_Building.Hobby.floor.Wall.A, groundFloor_Building.Corridor.floor.Wall.A,groundFloor_Building.WC_Storage.floor.Wall.A, groundFloor_Building.Kitchen.floor.Wall.A}, each final T_start=fill(TWalls_start, wallTypes.groundPlate_low_half.n), each final wallRec=wallTypes.groundPlate_low_half, each final energyDynamics=energyDynamicsWalls) if not (use_UFH) annotation (Placement(transformation( extent={{-4,-18},{4,18}}, rotation=-90, origin={0,-86})));Utilities.Interfaces.Adaptors.ConvRadToCombPort heatStarToCombAttic annotation (Placement(transformation( extent={{6,-5},{-6,5}}, rotation=180, origin={-36,51}))); + +28: Name 'portVent_in' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_a portVent_in[11](redeclare final package Medium = Medium) if useVentAirPort "Inlet for ventilation" annotation ( Placement(transformation(extent={{90,-78},{110,-58}}), iconTransformation( extent={{94,-70},{108,-56}}))); + +29: Name 'portVent_out' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Vent. Affected line: Modelica.Fluid.Interfaces.FluidPort_b portVent_out[11](redeclare final package Medium = Medium) if useVentAirPort "Outlet of Ventilation" annotation (Placement( transformation(extent={{90,-98},{110,-78}}), iconTransformation(extent={ {96,-92},{110,-78}}))); + +30: Missing documentation, Name 'thermOutside' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: therm, Outside. Affected line: Modelica.Thermal.HeatTransfer.Interfaces.HeatPort_a thermOutside annotation (Placement(transformation(extent={{-112,90},{-92,110}}))); + + +AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/BaseClasses/Distributor.mo +1: Name 'portsCirSup' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_b portsCirSup[n](redeclare each final package Medium = Medium) "Supply ports to circuits" annotation (Placement( visible=true, transformation( origin={0,60}, extent={{-10,-40},{10,40}}, rotation=90), iconTransformation( origin={-8,60}, extent={{-6,-24},{6,24}}, rotation=90))); + +2: Name 'portsCirRet' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: ports. Affected line: Modelica.Fluid.Interfaces.FluidPorts_a portsCirRet[n](redeclare each final package Medium = Medium) "Return ports from circuits" annotation ( Placement( visible=true, transformation( origin={0,-60}, extent={{-10,-40},{10,40}}, rotation=90), iconTransformation( origin={8,-62}, extent={{-6,-24},{6,24}}, rotation=90))); + +3: Missing documentation, Could not extract name from line and check correctness, is your type specification correct (full library path)?. Affected line: protected parameter Medium.ThermodynamicState sta_default=Medium.setState_pTX( T=Medium.T_default, p=Medium.p_default, X=Medium.X_default); + +4: Name 'rho_default' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: rho_default. Affected line: parameter Modelica.Units.SI.Density rho_default=Medium.density(sta_default) "Density, used to compute fluid volume"; AixLib/Fluid/HeatExchangers/ActiveWalls/UnderfloorHeating/UnderfloorHeatingCircuit.mo -1: Name 'dpValve_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Valve. Affected line: parameter Modelica.Units.SI.PressureDifference dpValve_nominal=0 "Pressure Difference set in regulating valve for pressure equalization in heating system" annotation (Dialog(group="Pressure Drop")); +1: Name 'dpValve_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Valve. Affected line: parameter Modelica.Units.SI.PressureDifference dpValve_nominal=1 "Pressure Difference set in regulating valve for pressure equalization in heating system" annotation (Dialog(group="Pressure Drop")); 2: Name 'dpFixed_nominal' contains parts with more/less than 3 characters or which are not part of special cases. Affected parts: Fixed. Affected line: parameter Modelica.Units.SI.PressureDifference dpFixed_nominal = 0 "Nominal additional pressure drop e.g. for distributor" annotation (Dialog(group="Pressure Drop"));