You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hello,
In the firmware I saw that the ECG sampling frequency is initialized to 125 SPS .. this is very low (the lowest the SoC is capable of), even too low for applications that requires precise estimations of the ECG signal (medical devices are usually sampling between 500Hz - 1 KHz and the SoC is capable of 8KHz). Is it possible to increase this value ? and eventually broadcast the signal on wifi or usb (the ESP32 serial port, even at the highest speed could not handle more than 2KHz with the packet definition of the firmware 2.x).
The text was updated successfully, but these errors were encountered:
Hello,
In the firmware I saw that the ECG sampling frequency is initialized to 125 SPS .. this is very low (the lowest the SoC is capable of), even too low for applications that requires precise estimations of the ECG signal (medical devices are usually sampling between 500Hz - 1 KHz and the SoC is capable of 8KHz). Is it possible to increase this value ? and eventually broadcast the signal on wifi or usb (the ESP32 serial port, even at the highest speed could not handle more than 2KHz with the packet definition of the firmware 2.x).
The text was updated successfully, but these errors were encountered: