Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[Known limitation]: Cannot convert multi-stream Spike2 (.smrx) #891

Open
adeverg opened this issue Jul 8, 2024 · 4 comments
Open

[Known limitation]: Cannot convert multi-stream Spike2 (.smrx) #891

adeverg opened this issue Jul 8, 2024 · 4 comments
Labels
bug Something isn't working

Comments

@adeverg
Copy link

adeverg commented Jul 8, 2024

Describe the issue

error "List index out of range". The file is smrx not smr

Screenshot 2024-07-08 145521

Steps to Reproduce

It works fine on Blackrock file.

Operating System

window 10

GUIDE Version

Version 1.0.0

Code of Conduct

Yes

Did you confirm this issue was not already reported?

Yes

@CodyCBakerPhD
Copy link
Collaborator

When you say

It works fine on Blackrock file.

Under the 'steps to reproduce' section

.smrx is a CED format, correct?

Whereas Blackrock is of the form .ns{x} where x is an integer from 0-9?

Otherwise, this type of error is usually due to multistream selection; we don't have any examples of multistream Spike2 files, would you be able to share a small (< 10 MB) example of your data?

@adeverg
Copy link
Author

adeverg commented Jul 8, 2024

Thanks a lot. Sorry for the misunderstanding, I meant that we had no issue before when we were using NS3 file from our blackrock recording.
I have to say that the files I'm trying to convert were not initially recorded with a CED system. They were recorded with the RC+S from Medtronic then later converted in CED format for an easier annotation of the data.
How should I share the smrx file since the format is not supported here?

@CodyCBakerPhD
Copy link
Collaborator

Hah... That is certainly a non-standard way of getting the data into that format, so no wonder we haven't seen it before

What software ran the Medtronic -> CED conversion?

How should I share the smrx file since the format is not supported here?

Google Drive / Dropbox / Box or whatever your usual preferred method is

@adeverg
Copy link
Author

adeverg commented Jul 8, 2024

You can either use the import function in spike 2 to import format like edf and create a new smrx file or you can use Spike2 MATLAB SON Interface (for conversion from TDT to spike2 for example)
https://drive.google.com/drive/folders/1rZmVRdhjCsXted9JUdnW21uWXouYR31D?usp=drive_link

https://emory-my.sharepoint.com/:f:/r/personal/adeverg_emory_edu/Documents/[conversion](https://emory-my.sharepoint.com/:f:/r/personal/adeverg_emory_edu/Documents/conversion?csf=1&web=1&e=M4zZZe)?csf=1&web=1&e=M4zZZe

@CodyCBakerPhD CodyCBakerPhD added the bug Something isn't working label Aug 7, 2024
@CodyCBakerPhD CodyCBakerPhD changed the title conversion for smrx file [Known limitation]: Conversion for multi-stream CED (.smrx) Aug 7, 2024
@CodyCBakerPhD CodyCBakerPhD changed the title [Known limitation]: Conversion for multi-stream CED (.smrx) [Known limitation]: Cannot convert multi-stream Spike2 (.smrx) Aug 7, 2024