You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Hi,
Thanks for developing such handy tool to obtain high granularity emissions factors for electricity!
I am trying to calculate the carbon emissions in real-time, and I just realized if I set range between start and end around 24 hours, turning on network losses leads to NaN result and turning on residual options (global or local) would reture "IndexError: index 0 is out of bounds for axis 0 with size 0"
Should I simply turn these options off or should I extend the range?
The text was updated successfully, but these errors were encountered:
MaChienhsiang
changed the title
Production mix sum is not equal to 1 for all countries
Real-time emissions factors
Jul 18, 2024
Hi,
Thanks for developing such handy tool to obtain high granularity emissions factors for electricity!
I am trying to calculate the carbon emissions in real-time, and I just realized if I set range between start and end around 24 hours, turning on network losses leads to NaN result and turning on residual options (global or local) would reture "IndexError: index 0 is out of bounds for axis 0 with size 0"
Should I simply turn these options off or should I extend the range?
The text was updated successfully, but these errors were encountered: