Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Add the Programmed Circuit Card as valid card for the ME Dual Interface #6250

Open
Bertel401 opened this issue Nov 24, 2024 · 2 comments
Open
Labels
Enhancement General suggestion or improvement. FTB Interactions Remastered

Comments

@Bertel401
Copy link

Modpack

FTB Interactions Remastered

Is your suggestion related to a problem? Please describe.

The Programmed Circuit Card enables you to add the relevant circuit for a pattern crafting recipe so the internal circuit of GregTech machines will be set to that number when crafting that specific recipe.
Unfortunately it is restricted to normal ME Interfaces only as the Programmed Circuit Card is part of Neeve's AE2: Extended Life Additions while the ME Dual Interface is part of the AE2 Fluid Crafting mod.
Due to the fact that the GregTech Assembler is using a wide assortment of different circuit numbers as well as fluids to do its daily operations it would be great if support could be added so the Programmed Circuit Card works with the ME Dual Interface as well.

Mod suggestion

No response

@Bertel401 Bertel401 added the Enhancement General suggestion or improvement. label Nov 24, 2024
@ArtpokeBr
Copy link
Collaborator

ArtpokeBr commented Nov 26, 2024

Hmm, this is something that should be reported to the Mod Devs, unfortunatly I don't think I would be able to add this compat :T

@Bertel401
Copy link
Author

Due to 1.12 being such an old version I wasn't sure how actively the mod authors are maintaining things. Looks like the issue is known but the fix was never released as an official version so far. Not sure if that helps in any way though as I guess there's not really a way to distribute unofficial releases via the default channels.

This is already a thing but not release bc it's on hiatus.
Consider using this build of NAE2 and for AE2-UEL, this build (Just a reupload of this but its artifact is expired. You can do a virus scan, verify its checksum, everything).
And yes you have to update both for the compatibility.

Original thread

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
Enhancement General suggestion or improvement. FTB Interactions Remastered
Projects
None yet
Development

No branches or pull requests

2 participants