Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Rather large difference between numbers shown #48

Open
mirabilos opened this issue Jul 5, 2022 · 0 comments
Open

Rather large difference between numbers shown #48

mirabilos opened this issue Jul 5, 2022 · 0 comments

Comments

@mirabilos
Copy link
Contributor

With the bandwidthtester receiver on an 100 Mbit/s ethernet link:

 summary  22.1  Transmit rate = 93584kbps, PLR =  0.00%( 0.00%), RTT = 0.009s, Queue delay = 0.025s
 summary  24.1  Transmit rate = 94336kbps, PLR =  0.00%( 0.00%), RTT = 0.008s, Queue delay = 0.024s
 summary  26.1  Transmit rate = 93545kbps, PLR =  0.00%( 0.00%), RTT = 0.012s, Queue delay = 0.033s

The -log CSV differs rather a lot though: the highest I get (shortly before ^Cing) is:

  • 84352424 Media coder bitrate [bps]
  • 85207824 Transmitted bitrate [bps]
  • 84976040 ACKed bitrate [bps]

That’s about 10 Mbit/s less! Where does this difference come from?

Looking at the code, the “Transmit rate” command line output seems to be tracked completely independently of the values that actually end up in the CSV. This doesn’t make any sense to me… shouldn’t the bandwidth be dependent on how many bytes per second you can actually get through the link?

Isn’t ACKed bitrate (plus packet overhead) the better estimate?

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment