To have the code figure out the start time for a continue run, you'll need to add some similar infrastructure as in CESM to handle this. I think it is worthwhile, but might take some effort. I suppose maybe the easiest/best thing to do would be to use the CESM restart infrastructure for both cesm-coupled and standalone. It would take some work to figure it out, but then it would be something that's the same between standalone and coupled and that would be a good thing. |
Just looking into the codes, fixing this needs some moving around of several subroutines, so |
It seems like simulation start time (
simStart
) needs to be specified for continue run for standalone run. This is to read runoff input at correct time. Similarly, restart file the needs to be specified infname_state_in
in control file.For cesm coupled run, the simulation start time is coming from the coupler, so it is ok. and fname_state_in is read in from rpointer file.
Erik (@ekluzek), do you think it is better to have the code figure out start time for continue run?
The text was updated successfully, but these errors were encountered: