! Include shortname defintions, so that the F77 code does not have to be modified to
! reference the CARMA structure.
#include "carma_globaer.h"
!! Calculates the vapor pressure of water vapor over liquid water and ice according
!! to the parameterization of Goff & Gratch [1946] as used in CAM (wv_saturation.F90).
!!
!! NOTE: <pvapl> and <pvapi> are vapor pressures in units of [dyne/cm^2]
!!
!! @author Chuck Bardeen
!! @version Dec-2010
subroutine vaporp_h2o_goff1946(carma, cstate, iz, rc, pvap_liq, pvap_ice)
! types
use carma_precision_mod
use carma_enums_mod
use carma_constants_mod
use carma_types_mod
use carmastate_mod
use carma_mod
implicit none
type(carma_type), intent(in) :: carma !! the carma object
type(carmastate_type), intent(inout) :: cstate !! the carma state object
integer, intent(in) :: iz !! z index
real(kind=f), intent(out) :: pvap_liq !! vapor pressure wrt liquid [dyne/cm2]
real(kind=f), intent(out) :: pvap_ice !! vapor pressure wrt ice [dyne[cm2]
integer, intent(inout) :: rc !! return code, negative indicates failure
! Local declarations
real(kind=f) :: tt
! Saturation vapor pressure over liquid water and water ice from
! Goff and Gatch, [1946].
tt = t(iz)
pvap_liq = 10.0_f * 10._f**(-7.90298_f * (373.16_f / tt - 1._f) + &
5.02808_f * log10(373.16_f / tt) - &
1.3816e-7_f * (10._f**(11.344_f * (1._f - tt / 373.16_f)) - 1._f) + &
8.1328e-3_f * (10._f**(-3.49149_f * (373.16_f / tt - 1._f)) - 1._f) + &
log10(1013.246_f)) * 100._f
pvap_ice = 10.0_f * 10._f**(-9.09718_f * (273.16_f / tt - 1._f) - 3.56654_f * &
log10(273.16_f / tt) + 0.876793_f * (1._f - tt / 273.16_f) + &
log10(6.1071_f)) * 100._f
! Check to see whether temperature is ouside range of validity for the parameterization.
!
! pvapl is defined for -50 C < T < 102 C , Gibbons [1990]
! pvapi is defined for T > -100 C
!
! NOTE: Don't stop the simulation if the limits are exceeded.
if ((t(iz) .le. 173.0_f) .or. (t(iz) .ge. 375.0_f)) then
! if (do_print) then
! write(LUNOPRT,*) 'vaporp_h2o_goff1946::WARNING - Temperature', t(iz), &
! ' out of range at iz = ', iz, "lat=", lat, "lon=", lon
! end if
rc = RC_WARNING
endif
! Return to caller with vapor pressures evaluated.
return