diff --git a/SampleComputationsOutput.txt b/SampleComputationsOutput.txt index 5c04a8d..46a0c30 100644 --- a/SampleComputationsOutput.txt +++ b/SampleComputationsOutput.txt @@ -1,5 +1,5 @@ Show HG TRV/HP model computations. -Date/time: Tue Aug 01 18:04:02 BST 2023 +Date/time: Mon Sep 11 16:34:59 BST 2023 Hardwired model, electricity demand normal / setback: 769W / 815W Parameterised model, all default parameters, electricity demand normal / setback: 769W / 815W @@ -51,3 +51,170 @@ Glasgow (EGPF) 2018 hourly temperatures Percentage of hours that room setback raises heat pump demand: 56% Heat mean demand: with no setback 938W, with setback 832W; -11% change with setback Heat pump mean power: with no setback 327W, with setback 339W; 4% change with setback + +Bungalow (original) vs detached: +Parameterised bungalow model, fixes applied for doors and CoP temperature, electricity demand normal / setback: 812W / 895W +Parameterised detached model, fixes applied for doors and CoP temperature, electricity demand normal / setback: 1131W / 1348W + +7 towns/cites, 10Y hourly data (201x, 87648 hours), bungalow and detached, two room heating patterns: +Belfast (weather station at EGAA): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 940W, with setback 830W; -12% change with setback + Heat pump mean power: with no setback 324W, with setback 334W; 3% change with setback + Percentage of hours that room setback raises heat pump demand: 56% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 940W, with setback 830W; -12% change with setback + Heat pump mean power: with no setback 324W, with setback 322W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 36% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1442W, with setback 1273W; -12% change with setback + Heat pump mean power: with no setback 469W, with setback 523W; 12% change with setback + Percentage of hours that room setback raises heat pump demand: 77% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1442W, with setback 1273W; -12% change with setback + Heat pump mean power: with no setback 469W, with setback 465W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 32% +Manchester (weather station at EGCC): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 875W, with setback 772W; -12% change with setback + Heat pump mean power: with no setback 302W, with setback 311W; 3% change with setback + Percentage of hours that room setback raises heat pump demand: 52% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 875W, with setback 772W; -12% change with setback + Heat pump mean power: with no setback 302W, with setback 300W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 33% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1344W, with setback 1186W; -12% change with setback + Heat pump mean power: with no setback 437W, with setback 487W; 12% change with setback + Percentage of hours that room setback raises heat pump demand: 72% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1344W, with setback 1186W; -12% change with setback + Heat pump mean power: with no setback 437W, with setback 433W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 29% +Cardiff (weather station at EGFF): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 800W, with setback 700W; -13% change with setback + Heat pump mean power: with no setback 271W, with setback 277W; 2% change with setback + Percentage of hours that room setback raises heat pump demand: 47% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 800W, with setback 700W; -13% change with setback + Heat pump mean power: with no setback 271W, with setback 267W; -2% change with setback + Percentage of hours that room setback raises heat pump demand: 26% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1229W, with setback 1075W; -13% change with setback + Heat pump mean power: with no setback 394W, with setback 436W; 10% change with setback + Percentage of hours that room setback raises heat pump demand: 68% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1229W, with setback 1075W; -13% change with setback + Heat pump mean power: with no setback 394W, with setback 388W; -2% change with setback + Percentage of hours that room setback raises heat pump demand: 22% +London (weather station at EGLL): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 743W, with setback 652W; -12% change with setback + Heat pump mean power: with no setback 253W, with setback 260W; 2% change with setback + Percentage of hours that room setback raises heat pump demand: 43% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 743W, with setback 652W; -12% change with setback + Heat pump mean power: with no setback 253W, with setback 250W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 26% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1140W, with setback 1000W; -12% change with setback + Heat pump mean power: with no setback 368W, with setback 407W; 11% change with setback + Percentage of hours that room setback raises heat pump demand: 62% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1140W, with setback 1000W; -12% change with setback + Heat pump mean power: with no setback 368W, with setback 363W; -1% change with setback + Percentage of hours that room setback raises heat pump demand: 22% +Newcastle (weather station at EGNT): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 954W, with setback 846W; -11% change with setback + Heat pump mean power: with no setback 331W, with setback 343W; 4% change with setback + Percentage of hours that room setback raises heat pump demand: 58% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 954W, with setback 846W; -11% change with setback + Heat pump mean power: with no setback 331W, with setback 331W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 39% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1465W, with setback 1298W; -11% change with setback + Heat pump mean power: with no setback 479W, with setback 536W; 12% change with setback + Percentage of hours that room setback raises heat pump demand: 77% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1465W, with setback 1298W; -11% change with setback + Heat pump mean power: with no setback 479W, with setback 477W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 35% +Glasgow (weather station at EGPF): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 954W, with setback 845W; -11% change with setback + Heat pump mean power: with no setback 332W, with setback 343W; 4% change with setback + Percentage of hours that room setback raises heat pump demand: 56% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 954W, with setback 845W; -11% change with setback + Heat pump mean power: with no setback 332W, with setback 331W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 37% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1465W, with setback 1297W; -11% change with setback + Heat pump mean power: with no setback 479W, with setback 536W; 12% change with setback + Percentage of hours that room setback raises heat pump demand: 77% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1465W, with setback 1297W; -11% change with setback + Heat pump mean power: with no setback 479W, with setback 477W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 33% +Edinburgh (weather station at EGPH): + Archetype bungalow + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 970W, with setback 859W; -11% change with setback + Heat pump mean power: with no setback 337W, with setback 349W; 4% change with setback + Percentage of hours that room setback raises heat pump demand: 58% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 970W, with setback 859W; -11% change with setback + Heat pump mean power: with no setback 337W, with setback 337W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 38% + Archetype detached + Layout ABAB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=true, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1488W, with setback 1319W; -11% change with setback + Heat pump mean power: with no setback 487W, with setback 546W; 12% change with setback + Percentage of hours that room setback raises heat pump demand: 78% + Layout AABB + Scenario base model parameters: ModelParameters[doorsPerInternalWall=1.0, correctCoPForFlowVsMW=true, roomsAlternatingABAB=false, externalAirTemperatureC=-3.0] + Heat mean demand: with no setback 1488W, with setback 1319W; -11% change with setback + Heat pump mean power: with no setback 487W, with setback 485W; -0% change with setback + Percentage of hours that room setback raises heat pump demand: 35%