Notifications
You must be signed in to change notification settings - Fork 6
/
Copy pathscript_time_rainWindCheck.lua
405 lines (370 loc) · 19.5 KB
/
script_time_rainWindCheck.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
-- script_time_rainWindCheck.lua for Domoticz
-- Author: CreasolTech https://www.creasol.it
-- This LUA script checks rain and wind data, and controls
-- * outdoor power outlet (in the garden), that can be disabled when raining
-- * mechanical ventilation: activates it only when there is enough wind and not from certain directions (to prevent stove smoke from the neighboor to enter into the house).
-- * if both heat pump and ventilation are active, also activates the hydronic coil inside the ventilation machine (to pre-heat/cool the air)
-- * if WindGuru station id and password are available, export wind/temperature/humidity data to WindGuru website
-- * fan/aspirator in the attic, used for cooling the attic in the Summer, or dehumidifing it, or heat in the Winter
-- * Control the power outlet connected to a mosquitto killer
-- This script needs also to access two configuration files:
-- globalvariables.lua
-- globalfunctions.lua
-- Put this script and the 2 configuration files on DOMOTICZDIR/scripts/lua
RAINTIMEOUT=30 -- Wait 30 minutes after rainCounter stops incrementing and rainRate returns to zero, before determining that the rain is over.
VENTILATION_START_WINTER=270 -- Start ventilation 4.5 hours after SunRise (Winter)
VENTILATION_START_SUMMER=120 -- Start ventilation 2 hours after SunRise (Summer)
VENTILATION_STOP=-60 -- normally stop ventilation 60 minutes before Sunset
VENTILATION_TIME=150 -- ventilation ON for max 6 hours a day
VENTILATION_TIME_ADD_SUNNY=60 -- adding time, in minutes, in weather is good
VENTILATION_TIME_ADD=40 -- additional time (in minutes) when ventilation is forced ON (this works even after SunSet+VENTILATION_STOP)
--VENTILATION_TIME_ADD=300 -- very long time (in minutes), useful when dining with friends
--VENTILATION_START_NIGHT=210 -- start at night to renew air in the bedroom. Set to 1400 or more to disable
VENTILATION_START_NIGHT=1500 -- set to 1440 or more to disable
VENTILATION_STOP_NIGHT=270
CLOUDS_TODAY_DEV="Clouds_today" -- weather forecast for today: percentage of clouds
-- This section is used to enable one or two fans in the attic for cooling, heating or drying.
-- A virtual "Selector Switch" named as ATTIC_SELECTOR_DEV variable should be create, with state "Off", "On", "Winter", "Summer" used to enable these function modes
ATTIC_FAN_DEV="Fan_Attic" -- Fan used for cooling the attic during the Summer. "" = not used. DomBus36 in the attic, port 7
ATTIC_FAN2_DEV="" -- Aspirator used for cooling the attic during the Summer. "" = not used. DomBus36 in the attic, port 8
ATTIC_SELECTOR_DEV="Attic_Fans_Active" -- Virtual selector switch to be created manually with levels "Off", "On", "Winter", "Summer"
ATTIC_TEMP_DEV="Temp_Attic" -- Temperature sensor in the attic. DomBusTH in the attic.
ATTIC_DELTA_START=8
ATTIC_DELTA_STOP=5
MOSQUITO_DEV="Socket_GarageVerde" -- power outlet used to supply the mosquito killer ("" if not used) - DomBus31 in the laundry
MOSQUITTO_SELECTOR_DEV="Mosquitto_Killer_Active" -- Virtual selector switch to be created manually with levels "Off" and "On"
MOSQUITTO_START1=timeofday['SunsetInMinutes']-60 -- start at Sunset - 2h
MOSQUITTO_STOP1=1380 -- stop at Sunset - 30m
MOSQUITTO_START2=2 -- start at Midnight
MOSQUITTO_STOP2=120 -- stop at 120=02:00
TRASH_ALERT_TIME=1140 -- time when alert will be sent, in minutes: 19*60=1140
TRASH_DEV="Living_Buzzer" -- Buzzer or Led device to turn ON
dofile "scripts/lua/globalvariables.lua" -- some variables common to all scripts
dofile "scripts/lua/globalfunctions.lua" -- some functions common to all scripts
function RWCinit()
-- check or initialize the RWC table of variables, that will be saved, coded in JSON, into the zRainWindCheck Domoticz variable
if (RWC==nil) then RWC={} end
if (RWC['time']==nil) then RWC['time']=0 end -- minutes the RWC was ON, today
if (RWC['toff']==nil) then RWC['toff']=0 end -- minutes the RWC is OFF (used to disable power supply after 30 minutes)
if (RWC['maxtime']==nil) then RWC['maxtime']=VENTILATION_TIME end -- minutes the CMV was ON, today
if (RWC['maxtime']<0) then RWC['maxtime']=0 end
if (RWC['auto']==nil) then RWC['auto']=0 end -- 1 of CMV has been started automatically by this script
if (RWC['wind']==nil) then RWC['wind']='' end
if (RWC['cd']==nil) then RWC['cd']=0 end -- car distance
end
DEBUG_LEVEL=E_INFO
--DEBUG_LEVEL=E_DEBUG
DEBUG_PREFIX="RainWindCheck: "
commandArray={}
timeNow = os.date("*t")
minutesNow = timeNow.min + timeNow.hour * 60 -- number of minutes since midnight
json=require("dkjson")
log(E_DEBUG,"====================== RainWindCheck ============================")
-- extract the rain rate (otherdevices[dev]="rainRate;rainCounter")
i=0
-- otherdevices[RAINDEV]="0.0;21451.1")
for str in otherdevices[RAINDEV]:gmatch("[^;]+") do
if (i==0) then
rainRate=tonumber(str)/40
else
rainCounter=tonumber(str)
break;
end
i=i+1
end
-- extract wind direction and speed
-- Wind: 315;NW;9;12;6.1;6.1 315=direction; NW=direction, 9=speed 0.9m/s, 12=gust 1.2m/s
local w1, w2, w3, w4
for w1, w2, w3, w4 in otherdevices[WINDDEV]:gmatch("([^;]+);([^;]+);([^;]+);([^;]+).*") do
windDirection=tonumber(w1)
windDirectionName=w2
windSpeed=tonumber(w3)
windGust=tonumber(w4)
break
end
if (TEMPERATURE_OUTDOOR_DEV~=nil and TEMPERATURE_OUTDOOR_DEV~='') then
-- temperature from weather station value should be in the format "12.20;42;0;1017;0"
--log(E_DEBUG,"WindGuru: TEMPERATURE_OUTDOOR="..otherdevices[TEMPERATURE_OUTDOOR_DEV])
for w1, w2, w3, w4 in otherdevices[TEMPERATURE_OUTDOOR_DEV]:gmatch("([^;]+);([^;]+);([^;]+);([^;]+).*") do
outdoorTemp=tonumber(w1)
outdoorRH=tonumber(w2)
outdoorBaro=tonumber(w4)
break
end
end
-- If it's raining more than 8mm/hour, disable the 230V socket in the garden
dev='Socket_Garden' -- socket device
if (otherdevices[dev]=='On' and rainRate>8) then -- more than 8mm/h
log(E_WARNING,"Device "..dev.." is On while raining (rainRate="..rainRate..") => turn OFF")
commandArray[dev]='Off'
end
-- check ventilation: enabled since 2 hours after sunrise, for 6 hours, and stop by 30 minutes before sunset
-- During the winter, ventilation is disabled when wind from W or S to avoid smell from combustion smoke from adjacent buildings using wood heaters.
checkVar('raining',0,0) -- create uservariable "raining" if it does not exist
raining=uservariables['raining'] -- 0 => not raining; 30, 29, 28, 27, ... => it's raining
if (uservariables['zRainWindCheck'] == nil) then
-- initialize variable
RWCinit() --init RWC table
-- create a Domoticz variable, coded in json, within all variables used in this module
checkVar('zRainWindCheck',2,json.encode(RWC))
RWC['rc']=rainCounter
else
RWC=json.decode(uservariables['zRainWindCheck'])
RWCinit() -- check that all variables in RWC table are initialized
end
--print("rainRate="..rainRate.." rainCounter="..rainCounter.." raining="..raining)
if (rainCounter~=RWC['rc'] or rainRate>0) then
-- it's raining
raining=RAINTIMEOUT;
RWC['rc']=rainCounter
else
if (raining>0) then
raining=raining-1
end
end
-- at start time, reset ventilation time (ventilation active for TIME minutes) and set auto=0
if (timeNow.month>=10 or timeNow.month<=5 or (timeNow.month==9 and timeNow.day>=10)) then
VENTILATION_START=VENTILATION_START_WINTER
else
VENTILATION_START=VENTILATION_START_SUMMER
end
if (minutesNow==(timeofday['SunriseInMinutes']+VENTILATION_START) and (timeNow.month~=1 or timeNow.day~=6)) then -- eclude ventilation on Jan 6!
RWC['time']=0
RWC['maxtime']=VENTILATION_TIME
if (CLOUDS_TODAY_DEV~='' and otherdevices[CLOUDS_TODAY_DEV]~=nil and tonumber(otherdevices[CLOUDS_TODAY_DEV])<20) then
RWC['maxtime']=RWC['maxtime']+VENTILATION_TIME_ADD_SUNNY
log(E_INFO,"Today ventilation time="..RWC['maxtime'].." increased because it's Sunny!")
end
RWC['auto']=0 -- 0=ventilation OFF, 1=ventilation ON by this script, 2=ventilation ON by this script, but disabled manually, 3=forced ON
end
if (otherdevices[VENTILATION_DEV]~=nil) then
log(E_INFO,"Ventilation "..otherdevices[VENTILATION_DEV]..": RWC['auto']="..RWC['auto'].." time="..RWC['time'].."/"..RWC['maxtime'].." windSpeed=".. (windSpeed/10) .."m/s windDirection="..windDirection.."°")
if (otherdevices[VENTILATION_DEV]=='Off') then
-- ventilation was OFF
-- disable VMC power supply after some minutes to reduce standby energy consumption
if (otherdevices[VENTILATION_COIL_DEV]=='Off') then -- VMC completely OFF
RWC['toff']=RWC['toff']+1
if (RWC['toff']>=1000) then RWC['toff']=999 end
if (RWC['toff']==30 and otherdevices[VENTILATION_RELAY_DEV]~='Off') then
commandArray[VENTILATION_RELAY_DEV]='Off'
end
end
if (RWC['auto']==1 or RWC['auto']==3) then
-- ventilation was ON by this script, but was forced OFF manually
RWC['auto']=2
if (RWC['time']>=VENTILATION_TIME or minutesNow>(timeofday['SunsetInMinutes']+VENTILATION_STOP)) then
-- already worked for a sufficient time: disable it
RWC['maxtime']=RWC['time']
end
elseif (minutesNow==VENTILATION_START_NIGHT) then
log(E_INFO,"Ventilation ON in the night: windSpeed=".. (windSpeed/10) .." ms/s, windDirection="..windDirection .."°")
RWC['auto']=1 -- ON
RWC['time']=0
RWC['maxtime']=VENTILATION_STOP_NIGHT-VENTILATION_START_NIGHT
commandArray[VENTILATION_ATT_DEV]="On"
deviceOn(VENTILATION_DEV,RWC,'d1')
if (otherdevices[VENTILATION_RELAY_DEV]~='On') then commandArray[VENTILATION_RELAY_DEV]='On' end -- activate relay to supply VMC
-- elseif (RWC['auto']==0 and RWC['time']<RWC['maxtime'] and windSpeed>=3 and (windDirection<160 or windSpeed>20)) then
elseif (RWC['auto']==0 and RWC['time']<RWC['maxtime']) then -- do not check wind direction
-- elseif (RWC['auto']==0 and RWC['time']<RWC['maxtime'] and windSpeed>=3 and (windDirection<210 or windSpeed>20)) then -- during the Winter, avoid smoke from South and West
-- elseif (RWC['auto']==0 and RWC['time']<RWC['maxtime'] and windSpeed>=3 and (windDirection>90 and windDirection<270)) then -- avoid smoke from the North
-- enable ventilation only in a specific time range if (minutesNow>=(timeofday['SunriseInMinutes']+VENTILATION_START) and minutesNow<(timeofday['SunsetInMinutes']+VENTILATION_STOP)) then
log(E_INFO,"Ventilation ON: windSpeed=".. (windSpeed/10) .." ms/s, windDirection="..windDirection .."°")
RWC['auto']=1 -- ON
deviceOn(VENTILATION_DEV,RWC,'d1')
end
else
-- ventilation is ON
log(E_DEBUG,"Ventilation is ON")
RWC['time']=RWC['time']+1
if (RWC['auto']==0) then
-- ventilation ON manually: add another 30 minutes (VENTILATION_TIME_ADD) to the working time ?
RWC['d1']='a' -- set device so it can be disabled automatically by deviceOff
RWC['auto']=3
if (RWC['time']>=RWC['maxtime']) then
RWC['maxtime']=RWC['maxtime']+VENTILATION_TIME_ADD
end
elseif (RWC['auto']==2) then
-- was forced OFF, now have been restarted => go for automatic
RWC['d1']='a' -- set device so it can be disabled automatically by deviceOff
RWC['auto']=1
elseif (RWC['auto']==1 or RWC['auto']==3) then
if (minutesNow==VENTILATION_STOP_NIGHT or (RWC['maxtime']==VENTILATION_TIME and minutesNow==(timeofday['SunsetInMinutes']+VENTILATION_STOP))) then
log(E_INFO,"Ventilation OFF: reached the stop time. Duration="..RWC['time'].." minutes")
RWC['auto']=0
commandArray[VENTILATION_ATT_DEV]='Off'
deviceOff(VENTILATION_DEV,RWC,'d1')
-- elseif (RWC['time']>=RWC['maxtime'] or (otherdevices['HeatPump_Mode']=='Winter' and (windSpeed==0 or (windDirection>160 and windSpeed<20)))) then
elseif (RWC['time']>=RWC['maxtime']) then -- do not check for windDirection (smoke)
-- elseif (RWC['time']>=RWC['maxtime'] or (otherdevices['HeatPump_Mode']=='Winter' and ((windDirection>160 and windSpeed<20)))) then -- during the Winter
-- elseif (RWC['time']>=RWC['maxtime'] or ((windDirection>210 or windDirection<45))) then -- avoid Smoke from Belluno
log(E_INFO,"Ventilation OFF: duration="..RWC['time'].." minutes, windSpeed=".. (windSpeed/10) .." m/s, windDirection=".. windDirection .."°")
RWC['auto']=0
deviceOff(VENTILATION_DEV,RWC,'d1')
end
end
end
if ((otherdevices[VENTILATION_DEV]=='On' or otherdevices[VENTILATION_COIL_DEV]=='On')) then
RWC['toff']=0
if (otherdevices[VENTILATION_RELAY_DEV]~='On') then
commandArray[VENTILATION_RELAY_DEV]='On' -- activate relay to supply VMC
end
end
end
if (false and otherdevices['HeatPump_Mode']=='Winter') then -- IGNORE VMC COIL ACTIVATION
-- in Winter, activate the ventilation water coil when heat pump and ventilation are ON (to heat the air from ventilation)
if ((otherdevices[VENTILATION_COIL_DEV]~=nil)) then
-- ventilation coil exists:
-- if ventilation is ON and heatpump ON => ventilation coil must be ON
-- else must be OFF
if (otherdevices[HEATPUMP_DEV]=='On' and otherdevices[VENTILATION_DEV]=='On' or otherdevices[VENTILATION_DEHUMIDIFY_DEV]=='On') then
if (otherdevices[VENTILATION_COIL_DEV]~='On') then
commandArray[VENTILATION_COIL_DEV]='On'
end
else
if (otherdevices[VENTILATION_COIL_DEV]~='Off') then
commandArray[VENTILATION_COIL_DEV]='Off'
end
end
end
end
if (WINDGURU_USER ~= nil and WINDGURU_USER ~= '') then
-- publish wind data on WindGuru website
if (RWC['wind']==nil or RWC['wind']~=otherdevices[WINDDEV]) then
-- wind has changed
local windSpeedkn=string.format("%.2f", windSpeed*0.1943)
local windGustkn =string.format("%.2f", windGust*0.1943)
log(E_DEBUG,"WindGuru: "..otherdevices[WINDDEV].." Speed="..windSpeedkn.."kn Gust="..windGustkn.."kn Dir="..windDirection)
local windgurusalt=os.date('%Y%m%d%H%M%S')
local windgurusecret=windgurusalt..WINDGURU_USER..WINDGURU_PASS
local windgurucmd='echo -n ' .. windgurusecret .. ' | md5sum'
log(E_DEBUG,"WindGuru: create hash with the command "..windgurucmd)
local fd=assert(io.popen(windgurucmd, 'r'))
local windguruhash=assert(fd:read('*a')):match("(%w+)")
windgurucmd='curl -m 1 -s \'http://www.windguru.cz/upload/api.php?uid='..WINDGURU_USER..'&salt='..windgurusalt..'&hash='..windguruhash..
'&wind_avg='..windSpeedkn..'&wind_max='..windGustkn..'&wind_direction='..windDirection
windgurucmd=windgurucmd..'&temperature='..outdoorTemp..'&rh='..outdoorRH
windgurucmd=windgurucmd..'\''
log(E_DEBUG,"WindGuru cmd is "..windgurucmd)
-- ret=os.execute(windgurucmd)
fd=assert(io.popen(windgurucmd, 'r'))
ret=assert(fd:read('*a'))
log(E_DEBUG,"WindGuru returned: "..tostring(ret))
RWC['wind']=otherdevices[WINDDEV] -- save current wind state
end
end
-- If ATTIC_FAN_DEV is defined, manage cooling the attic during the Summer or heat during the Winter
if (ATTIC_FAN_DEV~="") then
atticTemp=tonumber(otherdevices[ATTIC_TEMP_DEV])
if (otherdevices["Attic_Fans_Active"]=="Off") then
deviceOff(ATTIC_FAN_DEV,RWC,"af1")
if (ATTIC_FAN2_DEV~="") then deviceOff(ATTIC_FAN2_DEV,RWC,"af2") end
elseif (otherdevices["Attic_Fans_Active"]=="On") then
deviceOn(ATTIC_FAN_DEV,RWC,"af1")
if (ATTIC_FAN2_DEV~="") then deviceOn(ATTIC_FAN2_DEV,RWC,"af2") end
elseif (otherdevices["Attic_Fans_Active"]=="Summer") then
if (timeNow.month>=5 and timeNow.month<=9 and otherdevices["Attic_Fans_Active"]=="Summer") then
if (otherdevices[ATTIC_FAN_DEV]=="Off") then
-- Fans are off
-- if (atticTemp>26 and outdoorTemp+ATTIC_DELTA_START<atticTemp and (minutesNow>120 or tonumber(uservariables["alarmLevel"])<=2)) then
if (atticTemp>28 and outdoorTemp+ATTIC_DELTA_START<atticTemp and (minutesNow%20)<15 and raining==0) then
deviceOn(ATTIC_FAN_DEV,RWC,"af1")
if (ATTIC_FAN2_DEV~="") then deviceOn(ATTIC_FAN2_DEV,RWC,"af2") end
end
else
-- Fans are On !!
-- if (atticTemp<26 or outdoorTemp+ATTIC_DELTA_STOP>atticTemp or (minutesNow<240 and tonumber(uservariables["alarmLevel"])>2)) then
if (atticTemp<27 or outdoorTemp+ATTIC_DELTA_STOP>atticTemp or (minutesNow%20>=15) or raining~=0) then
deviceOff(ATTIC_FAN_DEV,RWC,"af1")
if (ATTIC_FAN2_DEV~="") then deviceOff(ATTIC_FAN2_DEV,RWC,"af2") end
end
end
end
end
end
if (MOSQUITO_DEV~="") then
-- Manage the mosquito killer: turn on in the evening (if not raining) and turn off in case of rain or in the morning
if (otherdevices[MOSQUITO_DEV]=='Off') then
-- moquito killer not supplied
if (otherdevices[MOSQUITTO_SELECTOR_DEV]~='Off' and (minutesNow==MOSQUITTO_START1 or minutesNow==MOSQUITTO_START2) and raining==0) then
deviceOn(MOSQUITO_DEV,RWC,"MK")
end
else
-- mosquitoes killer already On
if (otherdevices[MOSQUITTO_SELECTOR_DEV]=='Off' or (minutesNow==MOSQUITTO_STOP1 or minutesNow==MOSQUITTO_STOP2) or raining~=0) then
deviceOff(MOSQUITO_DEV,RWC,"MK")
end
end
end
if (TRASH_ALERT_TIME~="" and TRASH_ALERT_TIME==minutesNow) then
-- custom function checking current date and weekday, and send alert to a led notifying that trash bin should be carried out
-- get week number
local fd=assert(io.popen("date '+%V'", 'r'))
local wnum=tonumber(assert(fd:read('*a')))
-- print("wday="..timeNow.wday.." wnum="..wnum)
if (timeNow.wday==3) then -- wday=1 => Sunday, 2 => Monday, ....
-- Tuesday: paper bin in odd weeks, plastic bin in even weeks
if ((wnum%2)==1) then
-- odd week
commandArray[TRASH_DEV]="Set Level 10" -- 1 flash on Led (DomBusTH device
else
-- even week
commandArray[TRASH_DEV]="Set Level 20"
end
elseif (timeNow.wday==5 and (wnum%2)==0) then
-- Thursday, even week
commandArray[TRASH_DEV]="Set Level 30"
elseif (timeNow.wday==1 and timeNow.day>=14 and timeNow.day<21) then
-- Sunday, and next is the 3rd Monday of the Month
commandArray[TRASH_DEV]="Set Level 40"
end
end
-- track car distance, and activate/deactivate power to the gate
VEHICLE_DISTANCE='eNiro: distance' -- Vehicle distance in Km
VEHICLE_ENGINE='eNiro: engine ON' -- Vehicle engine On/Off
VEHICLE_UPDATEREQ='eNiro: update req.' -- Command to force vehicle update
local carDistance=0 -- actual vehicle distance from house
if (VEHICLE_DISTANCE~='' and otherdevices[VEHICLE_DISTANCE]~=nil) then
carDistance=tonumber(otherdevices[VEHICLE_DISTANCE]) -- actual vehicle distance from house
end
if (timeNow.wday>=2 and timeNow.wday<=4 and (minutesNow==820 or minutesNow==1030 or minutesNow==1090) and carDistance>5) then
log(E_DEBUG,"GeoFence: Request vehicle update")
-- working days, time to come back home => force vehicle tracking
commandArray[VEHICLE_UPDATEREQ]='On'
if (uservariables['alarmLevel']<=2) then -- alarm=OFF or alarm=DAY
log(E_INFO,"GeoFence: Working day => turn gate power ON anyway")
commandArray[RELAY_GATE_DEV]='On'
end
end
if (carDistance~=RWC['cd']) then --RWC['cd']=previous vehicle distance
-- vehicle is moving
if (carDistance>RWC['cd']) then
-- vehicle is moving away
log(E_INFO,"GeoFence: Vehicle is moving away, from "..RWC['cd'].." to "..carDistance.."km")
-- turn off gate power supply?
-- if (otherdevices[RELAY_GATE_DEV]=='On') then -- gate supply is OFF when alarmLevel is NIGHT or AWAY
-- log(E_INFO,"GeoFence: carDistance increasing and gate power==On => turn Off")
-- commandArray[RELAY_GATE_DEV]='Off'
-- end
else
-- vehicle is approaching house
log(E_INFO,"GeoFence: Vehicle is approaching, from "..RWC['cd'].." to "..carDistance.."km")
if (carDistance<5 and otherdevices[VEHICLE_ENGINE]=='On') then
-- vehicle is approaching, and is near house
if (otherdevices[RELAY_GATE_DEV]=='Off') then
log(E_INFO,"GeoFence: carDistance<5km and gate power==Off => turn On")
commandArray[RELAY_GATE_DEV]='On'
end
end
end
RWC['cd']=carDistance
else
-- vehicle is not moving
if (carDistance<0.5 and timeNow.hour==21 and timeNow.minutes==0 and otherdevices[RELAY_GATE_DEV]=='On') then
log(E_INFO,"GeoFence: Car at home, time>=19:00 and gate power==On => turn Off")
commandArray[RELAY_GATE_DEV]='Off'
end
end
commandArray['Variable:raining']=tostring(raining)
commandArray['Variable:zRainWindCheck']=json.encode(RWC)
return commandArray