Notifications
You must be signed in to change notification settings - Fork 6
/
Copy pathscript_time_hotwater.lua
163 lines (144 loc) · 6.01 KB
/
script_time_hotwater.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
-- script_time_hotwater.lua for Domoticz
-- Author: CreasolTech https://www.creasol.it
-- This LUA script manage the Hot Water Heat Pump (controlled by Modbus) to optimize own consumption from photovoltaic
-- Optionally it's possible to use a relay to enable power supply to the HW heat pump (to avoid power consumption during the night)
dofile "scripts/lua/globalvariables.lua" -- some variables common to all scripts
dofile "scripts/lua/globalfunctions.lua" -- some functions common to all scripts
DEBUG_LEVEL=E_INFO
DEBUG_LEVEL=E_DEBUG -- remove "--" at the begin of line, to enable debugging
DEBUG_PREFIX="HotWater: "
commandArray={}
dofile "scripts/lua/config_hotwater.lua"
function hwTurnOff() -- turn Off the heatpump
if (setPoint>HW_SP_OFF) then
log(E_INFO,"Hot Water switched On -> Off: set SetPoint to a very low value to stop boiler")
setPointNew=HW_SP_OFF-10
elseif (setPoint<HW_SP_OFF) then
log(E_INFO,"Hot Water Off: set SetPoint to HW_SP_OFF")
setPointNew=HW_SP_OFF
end
end
-- in peak hours => OFF
-- between 12:00 and Sunset:
-- between 12:00 and 14:00 ON only if enough power is available from photovoltaic
-- after 14:00, ON
mode=otherdevices[HW_MODE]
if (HW_MODE=='' or otherdevices[HW_MODE]==nil) then
log(E_ERROR, "Please create a selector switch with Off, On, Auto states")
return commandArray
end
if (HW_POWERSUPPLY~='') then
if (otherdevices[HW_POWERSUPPLY]==nil) then
log(E_WARNING,"HotWater power supply defined, but device does not exist: "..HW_POWERSUPPLY)
goto hotwaterEnd
elseif (otherdevices[HW_POWERSUPPLY]=='Off') then
-- at 4:00 turn On relay to supply the heatpump, to measure the internal water temperature
if (timeNow.hour==HW_NIGHT_CHECKHOUR and timeNow.min==0 and mode=='Auto') then
commandArray[HW_POWERSUPPLY]='On' -- activate the hotwater heatpump in the night to be sure that water temperature is sufficient for the morning
log(E_INFO,"HotWater power supply On to check water tank temperature")
elseif (mode=='On') then
commandArray[HW_POWERSUPPLY]='On' -- activate the hotwater heatpump in the night to be sure that water temperature is sufficient for the morning
log(E_INFO,"HotWater mode is On => activate relay to supply the HotWater heat pump")
else
log(E_DEBUG,"HotWater power supply disabled: exit")
end
goto hotwaterEnd
end
end
log(E_DEBUG,"====================== "..DEBUG_PREFIX.." ============================")
setPoint=tonumber(otherdevices[HW_SETPOINT])
if (timeNow.month>=11 or timeNow.month<=4) then HW_SP_MIN=HW_SP_MIN_WINTER end -- in Winter, higher HW_SP_MIN than in Summer
if (setPoint==nil) then
log(E_WARNING,"Hardware disabled: exit!")
goto hotwaterEnd
end
setPointNew=setPoint
if (mode=='Off') then
hwTurnOff()
elseif (mode=='On') then
if (setPoint<HW_SP_MIN) then
log(E_INFO,"Hot Water switched On")
setPointNew=HW_SP_MIN
end
else
-- mode==Auto
setPointNew=HW_SP_OFF -- Default: OFF
if (peakPower()) then
if (setPoint>HW_SP_OFF) then
setPointNew=HW_SP_OFF
end
log(E_DEBUG, "Peak => setPoint="..setPointNew)
else
-- during the night, check that temperature is enough for shower in the morning
if (otherdevices[HW_POWERSUPPLY]=='On' and timeNow.hour>=HW_NIGHT_CHECKHOUR and timeNow.hour<=(HW_NIGHT_CHECKHOUR+2)) then -- during the night
if (tonumber(otherdevices[HW_TEMPWATER_TOP])<HW_SP_MIN) then
setPointNew=HW_SP_MIN -- set to 42°C
else
-- turn Off the heat pump
hwTurnOff()
hwPower=getPowerValue(otherdevices[HW_POWER])
if (hwPower<10) then
commandArray[HW_POWERSUPPLY]='Off' -- turn Off the relay supplying hotwater heatpump
end
end
elseif (timeofday["Daytime"] and timeNow.hour>=10) then
-- during the day
hwPower=getPowerValue(otherdevices[HW_POWER])
gridPower=getPowerValue(otherdevices[GRID_POWER_DEV]) -- Grid power meter
pvPower=getPowerValue(otherdevices[PV_POWER_DEV]) -- Photovoltaic on the roof
pvGardenPower=getPowerValue(otherdevices[PVGARDEN_POWER_DEV]) -- Photovoltaic on the roof
if (uservariables['avgPower']~=nil) then
avgPower=tonumber(uservariables['avgPower'])
if (gridPower<avgPower) then
gridPower=avgPower -- gridPower=-200W, avgPower=600W => keep gridPower=600W
end
end
availablePower=hwPower-gridPower-500
tempWaterBot=tonumber(otherdevices[HW_TEMPWATER_BOTTOM])
log(E_DEBUG, "DAY: gridPower="..gridPower.." pvPower="..pvPower.." pvGarden="..pvGardenPower.." hwPower="..hwPower.." tempWaterBot="..tempWaterBot)
if (availablePower>0) then
if (gridPower+pvPower<0) then
log(E_DEBUG,"Available power and PV in the garden is producing too much")
setPointNew=HW_SP_MAX
elseif (timeNow.hour>=12) then
log(E_DEBUG,"Available power and time >= 12")
setPointNew=HW_SP_MAX
else
setPointNew=HW_SP_NORMAL
end
else
if (timeNow.hour>=14) then
setPointNew=HW_SP_NORMAL
else
setPointNew=HW_SP_MIN
end
end
if (setPointNew>HW_SP_OFF and otherdevices[EVSTATE_DEV]=='Ch') then
log(E_DEBUG,"EV is charging: reduce setpoint to HW_SP_OFF")
hwTurnOff()
end
if (setPointNew>setPoint and hwPower<100) then
log(E_DEBUG,"HotWater is OFF and setPoint has been increased")
-- if HP_TEMPWATER_BOT + 15 > setPointNew => increase setPointNew to force start
if (tempWaterBot<setPointNew and tempWaterBot>=(setPointNew-15)) then
log(E_DEBUG,"Increase setpoint to tempWaterBot+15+1 to force heat pump start")
setPointNew=tempWaterBot+15+1
end
elseif (setPointNew<setPoint and hwPower>100) then
-- request to turn off the hotwater boiler: decrease the setpoint gradually to avoid continuous ON/OFF in case of clouds
log(E_DEBUG,"SetPoint "..setPoint.." -> "..setPointNew..": decrease it to "..setPoint-2)
if (setPoint-2>=setPointNew) then
setPointNew=setPoint-2
else
setPointNew=setPoint-1
end
end
end
end
end
log(E_DEBUG,"Hot Water setpoint: "..setPoint.." -> "..setPointNew)
if (setPointNew ~= setPoint) then
commandArray[1]={['UpdateDevice']=tostring(otherdevices_idx[HW_SETPOINT])..'|1|'.. setPointNew}
end
::hotwaterEnd::
return commandArray