Notifications
You must be signed in to change notification settings - Fork 6
/
Copy pathconfig_alarm.lua
143 lines (126 loc) · 6.6 KB
/
config_alarm.lua
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
-- scripts/lua/alarm_config.lua - Configuration file for alarm scripts
-- Written by Creasol, https://creasol.it/products
--
dofile "/home/pi/domoticz/scripts/lua/globalvariables.lua" -- some variables common to all scripts
dofile "/home/pi/domoticz/scripts/lua/globalfunctions.lua" -- some functions common to all scripts
-- Some constants: DON'T MODIFY
-- bitmask associated to alarmLevel: don't care
ALARM_OFF=1
ALARM_DAY=2
ALARM_NIGHT=4
ALARM_AWAY=8
ALARM_TEST=16
-- alarmStatus: don't care
STATUS_OK=0
STATUS_PREDELAY=1
STATUS_ALARM=2
-- telegram and debug msg level: don't care
E_NONE=0 -- log nothing
E_ERROR=1 -- log only errors
E_WARNING=2 -- log errors + warnings
E_INFO=3 -- log errors + warnings + info
E_DEBUG=4 -- log everything
-- DEBUG LEVEL on LOGS and TELEGRAM notifications
DEBUG_LEVEL=E_DEBUG -- 0 => log nothing, 1=> log alarms, 2=> more log, notify to telegram private chat.. 4=>DEBUG
TELEGRAM_LEVEL=E_WARNING -- 1=LOG only errors/activations 2=Log warnings
DEBUG_PREFIX=''
-- =================== Next table of variables MUST BE MODIFIED TO MATCH YOUR CONFIGURATION AND PREFERENCES ==============================
--
-- ALARMlist is a bit difficult to configure: for any type of alarm (Day, Night, Away, ...) set which PIRs and MCS sensors should be enabled
-- For example:
-- PIRlist={
-- {'PIR_Garage',15}, -- bitmask: 0x01 (binary 0b00000001)
-- {'PIR_Kitchen',15}, -- bitmask: 0x02 (binary 0b00000010)
-- {'PIR_Living',15}, -- bitmask: 0x04 (binary 0b00000100)
-- {'PIR_Stairway',15}, -- bitmask: 0x08 (binary 0b00001000)
-- {'PIR_Bedroom',15}, -- bitmask: 0x10 (binary 0b00010000)
-- }
--
-- ALARM OFF => no PIRs enabled => 0x00000000
-- ALARM Day => only Garage PIR is enabled => 0x00000001. To enable PIR_Garage (0x01) PIR_Stairway (0x08) and PIR_Bedroom (0x10) sum these items
-- (use an hex calculator) and write the result (0x00000019) in (ALARM Day,PIRs en) position
-- ALARM Night => Garage+Kitchen+Living+Stairway enabled => 1+2+4+8=15 => 0x0f in hex => 0x0000000f
-- ALARM Away => All PIRs enabled => 0xffffffff or 0x0000001f if only 5 pirs are installed
--
ALARMlist={
-- AlarmLevel: Name, Tampers PIRs en. MCS1 en. MCS2 en.
[0x01]={'ALARM OFF', 0xffffffff, 0x00000000, 0x00000000, 0x00000000}, -- Tampers: all enabled; PIRS: all disabled; MCS: all disabled
[0x02]={'ALARM Day', 0xffffffff, 0x00000003, 0xffffffff, 0xffffffff}, -- Only PIR1 and PIR2 enabled, all MCS enabled
[0x04]={'ALARM Night', 0xffffffff, 0x00000001, 0xffffffff, 0xffffffff}, -- Only PIR1 enabled, all MCS enabled
[0x08]={'ALARM Away', 0xffffffff, 0x00000001, 0xffffffff, 0xffffffff}, -- Only PIR1 enabled, all MCS enabled
[0x10]={'ALARM Test', 0xffffffff, 0xffffffff, 0xffffffff, 0xffffffff}, -- All PIRs and MCSs are enabled
}
-- List of magnetic contact sensors (window/door + associated shutter/blind)
-- Magnetic sensors name must start with MCS prefix
-- If the associated blind or window/door is missing, write ''
MCSlist={ -- MCS_window/door, MCS_shutter, delay[s]
{'MCS_Kitchen_Window1','MCS_Kitchen_Blind1',0,}, --00000001
{'MCS_Kitchen_Window2','MCS_Kitchen_Blind2',0,}, --00000002
{'MCS_Kitchen_Window3','MCS_Kitchen_Blind3',0,}, --00000004
{'MCS_Kitchen_Door','',10}, -- in case of alarm, "delayed sirens" must be activated after 15s (delay) --0008
{'MCS_Living_Window1','MCS_Living_Blind1',0}, --00000010 -- finestra1 non collegato
{'MCS_Living_Window2','MCS_Living_Blind2',0}, --00000020 -- finestra2 non collegato
{'MCS_Pranzo_Window1','MCS_Pranzo_Blind1',0}, --00000040
{'MCS_Pranzo_Window2','MCS_Pranzo_Blind2',0}, --00000080
{'MCS_Pranzo_Window3','MCS_Pranzo_Blind3',0}, --00000100
{'MCS_Sud_Door','MCS_Sud_Scuro',0}, --00000200
{'MCS_Lab_Window_Sud','MCS_Lab_Blind_Sud',0}, --00000400
{'MCS_Lab_Window_Nord','MCS_Lab_Blind_Nord',0}, --00000800
{'MCS_BagnoPT_Window','MCS_BagnoPT_Blind',0}, --00001000
{'MCS_Magazzino_Window_Sud','MCS_Magazzino_Blind_Sud',0}, --00002000
{'MCS_Magazzino_Window_Nord','MCS_Magazzino_Blind_Nord',0}, --00004000
{'MCS_Garage_Door_Magazzino','',0}, --00008000
{'MCS_Garage_Door_Pranzo','',0}, --00010000
{'','MCS_Scale_Blind',0}, --00020000
{'MCS_Notte_Scorrevole','',0}, --00040000
{'MCS_Bedroom_Door','',0}, --00080000
{'MCS_Bedroom_Window1','MCS_Bedroom_Blind1',0}, --00100000
{'MCS_Bedroom_Window2','MCS_Bedroom_Blind2',0}, --00200000
{'MCS_Bedroom_Window3','MCS_Bedroom_Blind3',0}, --00400000
{'','MCS_Stireria_Scuri',0}, --00800000
{'','MCS_BagnoP1_Blind',0}, --01000000
{'','MCS_Bedroom_Ospiti_Scuri',0}, --02000000
{'','MCS_Bedroom_Valentina_Blind1',0}, --04000000
{'','MCS_Bedroom_Valentina_Blind2',0}, --08000000
}
--PIR sensors name must start with PIR prefix
-- List of PIRs enabled when somebody is at home
PIRlist={
-- Name, Delay before activating external sirens
{'PIR_Garage',15},
{'PIR_SudEst',15},
{'PIR_GarageVerde',15},
}
-- Tampers name must start with TAMPER prefix
TAMPERlist={ -- device_name
{'TAMPER_Kitchen_Finestre'},
{'TAMPER_Kitchen_Living_Scuri'},
{'TAMPER_Sud'},
{'TAMPER_PT_Est'},
{'TAMPER_P1_Est'},
{'TAMPER_Camere11'},
{'TAMPER_Camere12'},
}
SIRENlist={ -- output_device, alarmLevel, delayed, duration[min] -- delayed should be 1 for sirens that should start after 10-15s delay in case of alarm activation by MCS of a door
{'SIREN_External', ALARM_AWAY, 1, 5},
{'SIREN_Internal', ALARM_DAY+ALARM_NIGHT+ALARM_AWAY, 0, 5},
{'SIREN_Internal_d', ALARM_DAY+ALARM_NIGHT+ALARM_AWAY, 0, 5},
{'Light_Bedroom', ALARM_NIGHT+ALARM_AWAY, 0, 5},
{'Light_Scale', ALARM_NIGHT+ALARM_AWAY, 0, 5},
} -- REMEMBER TO CONFIGURE THE LIST of IDX associated to the sirens on alarmSet.sh : this is needed to switch off sirens setting alarmLevel to OFF
ALARM_OTHERlist={
-- other devices. Syntax:
-- devicename, alarm_level (255 for any alarmLevel), sensor_value1, notification1, sensor_value2, notification2
{ 'ALARM_Supply_Raspberry',255, 'Off', 'PowerSupply to Raspberry is OFF', 'On','PowerSupply to Raspberry restored' },
}
ALARM_Lights={
-- light that are automatically switched ON/OFF when ALARM_AWAY, in the right sequence 1-> 2 -> 3 -> 2 -> 1 -> 2 -> 3 ....
-- light dev, min duration[s], max duration min/max delay before switching next ON
{'Light_Living', 20, 2700, 4, 7},
{'Light_Stairway' 12, 25, -2, 2},
{'Light_Bedroom', 20, 900, 0, 0},
}
-- Leds activated for few seconds when alarm has been activated
LEDS_ON={'Led_Bedroom1_Red','Led_Bedroom2_Red'}
-- Leds activated for few seconds when alarm has been disactivated
LEDS_OFF={'LEd_Bedroom1_Green','Led_Bedroom2_Green'}