To be run as CMS_MTD_CORE_COND
*/
INSERT INTO CMS_MTD_CORE_COND.KINDS_OF_CONDITIONS (NAME, IS_RECORD_DELETED, EXTENSION_TABLE_NAME, COMMENT_DESCRIPTION) VALUES ('SiPMBreakdownVoltage', 'F', 'SiPMBreakdownVoltage', 'A table containing data collected by the manufacturer from which the V_BD is obtained');
/*
To be run as CMS_MTD_TMING_COND
*/
DROP TABLE CMS_MTD_TMING_COND.SiPMBreakdownVoltage CASCADE CONSTRAINTS;
CREATE TABLE CMS_MTD_TMING_COND.SiPMBreakdownVoltage
(
RECORD_ID NUMBER(38) NOT NULL,
CONDITION_DATA_SET_ID NUMBER(38) NOT NULL,
VBreakDown NUMBER NOT NULL,
V1 NUMBER,
I1 number,
V2 number,
I2 number
)
PCTUSED 0
PCTFREE 10
INITRANS 1
MAXTRANS 255
STORAGE (
INITIAL 10M
NEXT 1M
MINEXTENTS 1
MAXEXTENTS UNLIMITED
PCTINCREASE 0
BUFFER_POOL DEFAULT
)
LOGGING
NOCOMPRESS
NOCACHE;
CREATE UNIQUE INDEX CMS_MTD_TMING_COND.SPMBrkdwnVltg_PK ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage (RECORD_ID);
ALTER TABLE CMS_MTD_TMING_COND.SiPMBreakdownVoltage ADD (
CONSTRAINT SPMBrkdwnVltg_PK
PRIMARY KEY
(RECORD_ID)
USING INDEX CMS_MTD_TMING_COND.SPMBrkdwnVltg_PK
ENABLE VALIDATE);
CREATE INDEX CMS_MTD_TMING_COND.SPMBrkdwnVltg_FK_I ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage (CONDITION_DATA_SET_ID);
ALTER TABLE CMS_MTD_TMING_COND.SiPMBreakdownVoltage ADD (
CONSTRAINT SPMBrkdwnVltg_FK
FOREIGN KEY (CONDITION_DATA_SET_ID)
REFERENCES CMS_MTD_CORE_COND.COND_DATA_SETS (CONDITION_DATA_SET_ID)
ENABLE VALIDATE);
GRANT SELECT ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO CMS_MTD_TMING_CONDITION_READER;
GRANT SELECT ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO PUBLIC;
GRANT INSERT ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO CMS_MTD_CORE_CONDITION_WRITER;
GRANT UPDATE ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO CMS_MTD_CORE_CONDITION_WRITER;
GRANT INSERT ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO CMS_MTD_PRTYP_TMING_WRT;
GRANT UPDATE ON CMS_MTD_TMING_COND.SiPMBreakdownVoltage TO CMS_MTD_PRTYP_TMING_WRT;
INSERT INTO CMS_MTD_CORE_COND.COND_TO_PART_RLTNSHPS
(KIND_OF_PART_ID, KIND_OF_CONDITION_ID, DISPLAY_NAME, IS_RECORD_DELETED)
VALUES ((SELECT KIND_OF_PART_ID FROM CMS_MTD_CORE_CONSTRUCT.KINDS_OF_PARTS WHERE
DISPLAY_NAME = 'SiPM' AND IS_RECORD_DELETED = 'F'),
(SELECT KIND_OF_CONDITION_ID FROM
CMS_MTD_CORE_COND.KINDS_OF_CONDITIONS WHERE EXTENSION_TABLE_NAME = 'SiPMBreakdownVoltage' AND
NAME = 'SiPMBreakdownVoltage'), 'Breakdown Voltage', 'F');