from models import HVAC
from models import HvacBuilding
from environments import HvacBuildingEnvironment
from util import HvacBuildingTracker
import numpy as np
from tensorforce.agents import PPOAgent
from tensorforce.execution import Runner
from tensorforce.contrib.openai_gym import OpenAIGym
# Create an instance of HVAC to simulate the Furnance
# use any parameters specific for your furnace
hvac = HVAC()
# Create the hvac building tracker to keep track of the simulation over time
tracker = HvacBuildingTracker()
# create the building model with the hvac and the tracker
conditioned_floor_area = 100
hvacBuilding = HvacBuilding(
hvac,
heat_mass_capacity=16500 * conditioned_floor_area,
heat_transmission=200,
initial_building_temperature=18,
conditioned_floor_area=conditioned_floor_area,
hvacBuildingTracker = tracker
)
environment = HvacBuildingEnvironment(hvacBuilding)
# a set of temperatures in Northern Utah, USA for one day
loganOutsideTemperatures = [1.11, 2.22, 1.67, 1.67, 2.22, 1.11, 1.11, 2.78, 4.44, 4.44, 5.56, 6.67, 6.67, 7.22, 6.67, 2.22, 2.22, 1.67, 1.11, 1.11, 0.56, 1.11, 0.00, 0.00]
print()
print("Starting Hvac Building Example")
print()
# simulate one day
numberOfHeatingOn = 0
# for outsideTemperature in loganOutsideTemperatures:
# # iterate through one hour with the same temperature
# for i in range(3600):
# hvacBuilding.step(outsideTemperature)
# if not hvac.HeatingIsShuttingDown and hvac.HeatingIsOn and hvacBuilding.current_temperature > 18.8889:#21:
# #print("Turning the Heater Off")
# hvac.TurnHeatingOff()
# if hvac.HeatingIsOn == False and hvacBuilding.current_temperature < 17.7778:#17:
# #print("Turning the Heater On")
# numberOfHeatingOn = numberOfHeatingOn + 1
# hvac.TurnHeatingOn()
#hvacBuilding.PrintSummary()
# todo run a loop with various parameters for the set points to determine the optimal temperature in terms of the delta
# Create a Proximal Policy Optimization agent
agent = PPOAgent(
states=dict(type='float', shape=(3,)),
actions=dict(type='bool', num_actions=1),
network=[
dict(type='dense', size=64),
dict(type='dense', size=64)
],
batching_capacity=1000,
step_optimizer=dict(
type='adam',
learning_rate=1e-4
)
)
def episode_finished(r):
if r.episode % 10 == 0:
print("Finished episode {ep} after {ts} timesteps".format(ep=r.episode + 1, ts=r.timestep + 1))
print("Episode reward: {}".format(r.episode_rewards[-1]))
print("Average of last 10 rewards: {}".format(np.mean(r.episode_rewards[-10:])))
return True
runner = Runner(agent, environment)
runner.run(num_timesteps=3600, num_episodes=3, episode_finished= episode_finished)
# Poll new state from client
#for outsideTemperature in loganOutsideTemperatures:
for i in range(2):
outsideTemperature = 1.1
# iterate through one hour with the same temperature
for i in range(3600):
state = hvacBuilding.get_state(outsideTemperature)
action = agent.act(state, True)
reward = hvacBuilding.Act(action)
agent.observe(reward=reward, terminal=False)
hvacBuilding.step(outsideTemperature)
#currently the only state is to turn on cooling or turn off
# if not hvac.HeatingIsShuttingDown and hvac.HeatingIsOn and hvacBuilding.current_temperature > 18.8889:#21:
# #print("Turning the Heater Off")
# hvac.TurnHeatingOff()
# if hvac.HeatingIsOn == False and hvacBuilding.current_temperature < 17.7778:#17:
# #print("Turning the Heater On")
# numberOfHeatingOn = numberOfHeatingOn + 1
# hvac.TurnHeatingOn()